21 research outputs found

    Impact of blood storage and sample handling on quality of high dimensional flow cytometric data in multicenter clinical research

    Get PDF
    Obtaining reliable and reproducible high quality data in multicenter clinical research settings requires design of optimal standard operating procedures. While the need for standardization in sample processing and data analysis is well-recognized, the impact of sample handling in the pre-analytical phase remains underestimated. We evaluated the impact of sample storage time (approximate to transport time) and temperature, type of anticoagulant, and limited blood volume on reproducibility of flow cytometric studies. EDTA and Na-Heparin samples processed with the EuroFlow bulk lysis protocol, stained and stored at 4 degrees C showed fairly stable expression of cell surface markers and distribution of the major leukocyte populations for up to 72 h. Additional sample fixation (1% PFA, Fix & Perm) did not have any beneficial effects. Blood samples stored for < 24 h at room temperature before processing and staining seemed suitable for reliable immunophenotyping, although losses in absolute cell numbers were observed. The major losses were observed in myeloid cells and monocytes, while lymphocytes seemed less affected. Expression of cell surface markers and population distribution were more stable in Na-Heparin blood than in EDTA blood. However, storage of Na-Heparin samples was associated with faster decrease in leukocyte counts over time. Whole blood fixation strategies (Cyto-Chex, TransFix) improved long-term population distribution, but were detrimental for expression of cellular markers. The main conclusions from this study on healthy donor blood samples were successfully confirmed in EDTA clinical (patient) blood samples with different time delays until processing. Finally, we recognized the need for adjustments in bulk lysis in case of insufficient blood volumes. Despite clear overall conclusions, individual markers and cell populations had different preferred conditions. Therefore, specific guidelines for sample handling should always be adjusted to the clinical application and the main target leukocyte population

    Development of a standardized and validated flow cytometry approach for monitoring of innate myeloid immune cells in human blood

    Get PDF
    Innate myeloid cell (IMC) populations form an essential part of innate immunity. Flow cytometric (FCM) monitoring of IMCs in peripheral blood (PB) has great clinical potential for disease monitoring due to their role in maintenance of tissue homeostasis and ability to sense micro-environmental changes, such as inflammatory processes and tissue damage. However, the lack of standardized and validated approaches has hampered broad clinical implementation. For accurate identification and separation of IMC populations, 62 antibodies against 44 different proteins were evaluated. In multiple rounds of EuroFlow-based design-testing-evaluation-redesign, finally 16 antibodies were selected for their non-redundancy and separation power. Accordingly, two antibody combinations were designed for fast, sensitive, and reproducible FCM monitoring of IMC populations in PB in clinical settings (11-color; 13 antibodies) and translational research (14-color; 16 antibodies). Performance of pre-analytical and analytical variables among different instruments, together with optimized post-analytical data analysis and reference values were assessed. Overall, 265 blood samples were used for design and validation of the antibody combinations and in vitro functional assays, as well as for assessing the impact of sample preparation procedures and conditions. The two (11- and 14-color) antibody combinations allowed for robust and sensitive detection of 19 and 23 IMC populations, respectively. Highly reproducible identification and enumeration of IMC populations was achieved, independently of anticoagulant, type of FCM instrument and center, particularly when database/software-guided automated (vs. manual "expert-based") gating was used. Whereas no significant changes were observed in identification of IMC populations for up to 24h delayed sample processing, a significant impact was observed in their absolute counts after >12h delay. Therefore, accurate identification and quantitation of IMC populations requires sample processing on the same day. Significantly different counts were observed in PB for multiple IMC populations according to age and sex. Consequently, PB samples from 116 healthy donors (8-69 years) were used for collecting age and sex related reference values for all IMC populations. In summary, the two antibody combinations and FCM approach allow for rapid, standardized, automated and reproducible identification of 19 and 23 IMC populations in PB, suited for monitoring of innate immune responses in clinical and translational research settings

    Antifibrinolytics in liver transplantation

    No full text

    Number of measurement days needed for obtaining a reliable estimate of home blood pressure and hypertension status

    No full text
    Purpose: Out-of-office blood pressure (BP) measurements are essential for the diagnosis and monitoring of hypertension. Current guidelines vary in their recommendations on the protocol for home blood pressure monitoring (HBPM). We aimed to assess the number of blood pressure (BP) measurement days needed for a reliable estimation of true home BP (the expected BP level over time) and hypertension status, using the European guideline-based 7-day HBPM protocol as a reference. Materials and Methods: Data from 567 adults who performed a 7-day HBPM were analysed. Blood pressure was measured twice daily (morning and evening readings) using the Microlife Average Mode (MAM), which takes a weighted average of 3 consecutive BP readings. The variability of average BP for an increasing number of measurements was assessed using a linear mixed model including a random intercept per individual and correlated residuals. The reliability of home hypertension status was assessed by the κ statistic. Results: Mean home BP of the population was 143 ± 16/84 ± 10 mm Hg. On average, the first BP measurements gave the highest values which then decreased over time. Systolic BP in the morning was systematically lower than systolic BP in the evening (142 ± 17mm Hg versus 144 ± 17 mm Hg, p  Conclusion: Twice-daily MAM BP measurements for 3 consecutive days provide a reliable estimate of home BP. At least 4.5 consecutive days of HBPM are required for a reliable diagnosis of home hypertension.</p

    Aprotinin in orthotopic liver transplantation:Evidence for a prohemostatic, but not a prothrombotic, effect

    No full text
    Aprotinin reduces blood transfusion requirements in orthotopic liver transplantation (OLT). Concern has been voiced about the potential risk for thrombotic complications when aprotinin is used. The aim of this study is to evaluate the effects of aprotinin on the two components of the hemostatic system (coagulation and fibrinolysis) in patients undergoing OLT. As part of a larger, randomized, double-blind, placebo-controlled study, we compared coagulation (fibrinogen level, activated partial thromboplastin time [aPTT], prothrombin time, and platelet count) and fibrinolytic variables (tissue-type plasminogen activator [tPA] antigen and activity, plasminogen activator inhibitor activity, and D-dimer), as well as thromboelastography (reaction time [r], clot formation time, and maximum amplitude) in 27 patients administered either high-dose aprotinin (2 X 10(6) kallikrein inhibitor units [KIU] at induction, continuous infusion of I X 106 KIU/h, and 1 X 10(6) KIU before reperfusion; n = 10), regular-dose aprotinin (2 X 106 KIU at induction and continuous infusion of 0.5 X 10(6) KIU/h; n = 8), or placebo (n = 9) during OLT. Blood samples were drawn at seven standardized intraoperative times. Baseline characteristics were similar for the three groups. During the anhepatic and postreperfusion periods, fibrinolytic activity (plasma D-dimer and tPA antigen levels) was significantly lower in aprotinin-treated patients compared with the placebo group. Interestingly, coagulation times (aPTT and r) were significantly more prolonged in aprotinin-treated patients than the placebo group. No difference was seen in the incidence of perioperative thrombotic complications in the entire study population (n = 137). Aprotinin has an anticoagulant rather than a procoagulant effect. Its blood-sparing (prohemostatic) effect appears to be the overall result of a strong antifibrinolytic and a weaker anticoagulant effect. These findings argue against a prothrombotic effect of aprotinin in patients undergoing OLT
    corecore