702 research outputs found

    Optical structure and function of the white filamentary hair covering the edelweiss bracts

    Full text link
    The optical properties of the inflorescence of the high-altitude ''Leontopodium nivale'' subsp. ''alpinum'' (edelweiss) is investigated, in relation with its submicrometer structure, as determined by scanning electron microscopy. The filaments forming the hair layer have been found to exhibit an internal structure which may be one of the few examples of a photonic structure found in a plant. Measurements of light transmission through a self-supported layer of hair pads taken from the bracts supports the idea that the wooly layer covering the plant absorbs near-ultraviolet radiation before it reaches the cellular tissue. Calculations based on a photonic-crystal model provides insight on the way radiation can be absorbed by the filamentary threads.Comment: 9 pages, 13 figures. Published pape

    Stability and relapse after orthodontic treatment of deep bite cases—a long-term follow-up study

    Get PDF
    The purpose of this long-term follow-up study was twofold—firstly, to assess prevalence of relapse after treatment of deep bite malocclusion and secondly, to identify risk factors that predispose patients with deep bite malocclusion to relapse. Sixty-one former patients with overbite more than 50% incisor overlap before treatment were successfully recalled. Clinical data, morphometrical measurements on plaster casts before treatment, after treatment and at long-term follow-up, as well as cephalometric measurements before and after treatment were collected. The median follow-up period was 11.9 years. Patients were treated by various treatment modalities, and the majority of patients received at least a lower fixed retainer and an upper removable bite plate during retention. Relapse was defined as increase in incisor overlap from below 50% after treatment to equal or more than 50% incisor overlap at long-term follow-up. Ten per cent of the patients showed relapse to equal or larger than 50% incisor overlap, and their amount of overbite increase was low. Among all cases with deep bite at follow-up, gingival contact and palatal impingement were more prevalent in partially corrected noncompliant cases than in relapse cases. In this sample, prevalence and amount of relapse were too low to identify risk factors of relaps

    A revised generic classification of the tribe Sileneae (Caryophyllaceae)

    Full text link
    Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/73198/1/j.1756-1051.2000.tb00760.x.pd

    Exposure to low-dose radiation and the risk of breast cancer among women with a familial or genetic predisposition:a meta-analysis

    Get PDF
    Women with familial or genetic aggregation of breast cancer are offered screening outside the population screening programme. However, the possible benefit of mammography screening could be reduced due to the risk of radiation-induced tumours. A systematic search was conducted addressing the question of how low-dose radiation exposure affects breast cancer risk among high-risk women. A systematic search was conducted for articles addressing breast cancer, mammography screening, radiation and high-risk women. Effects of low-dose radiation on breast cancer risk were presented in terms of pooled odds ratios (OR). Of 127 articles found, 7 were selected for the meta-analysis. Pooled OR revealed an increased risk of breast cancer among high-risk women due to low-dose radiation exposure (OR = 1.3, 95% CI: 0.9- 1.8). Exposure before age 20 (OR = 2.0, 95% CI: 1.3-3.1) or a mean of a parts per thousand yen5 exposures (OR = 1.8, 95% CI: 1.1-3.0) was significantly associated with a higher radiation-induced breast cancer risk. Low-dose radiation increases breast cancer risk among high-risk women. When using low-dose radiation among high-risk women, a careful approach is needed, by means of reducing repeated exposure, avoidance of exposure at a younger age and using non-ionising screening techniques

    Validations of the names of seven Podocarpaceae macrofossils

    Get PDF
    Seven names of macrofossil taxa belonging to Podocarpaceae are here validated; they were all previously published but not validly so under the International Code of Botanical Nomenclature. The names apply to species in the genera Acmopyle Pilg. [A. setiger (Townrow) R. S. Hill & R. J. Carp. ex R. R. Mill & R. S. Hill], Dacrycarpus (Endl.) de Laub. [D. praecupressinus (Ettingsh.) D. R. Greenw. ex R. R. Mill & R. S. Hill], Falcatifolium de Laub. [F. eocenicum (D. R. Greenw.) R. S. Hill & L. J. Scriven ex R. R. Mill & R. S. Hill], Prumnopitys Phil. [P. tasmanica (Townrow) D. R. Greenw. ex R. R. Mill & R. S. Hill], Sigmaphyllum R. S. Hill & L. J. Scriven [S. australe (D. R. Greenw.) R. S. Hill & L. J. Scriven ex R. R. Mill & R. S. Hill], Smithtonia R. S. Hill & M. Pole [S. lanceolata (D. R. Greenw.) R. S. Hill & M. Pole ex R. R. Mill & R. S. Hill] and Willungia R. S. Hill & M. Pole [W. maslinensis (D. T. Blackburn) R. S. Hill & M. Pole ex R. R. Mill & R. S. Hill]. All these combinations were originally published without exact basionym references; instead, the authors cited the complete pagination of the paper in which the intended basionym was made.Robert R. Mill and Robert S. Hil

    Development of a dynamic myocardial perfusion phantom model for tracer kinetic measurements

    Get PDF
    BACKGROUND: Absolute myocardial perfusion imaging (MPI) is beneficial in the diagnosis and prognosis of patients with suspected or known coronary artery disease. However, validation and standardization of perfusion estimates across centers is needed to ensure safe and adequate integration into the clinical workflow. Physical myocardial perfusion models can contribute to this clinical need as these can provide ground-truth validation of perfusion estimates in a simplified, though controlled setup. This work presents the design and realization of such a myocardial perfusion phantom and highlights initial performance testing of the overall phantom setup using dynamic single photon emission computed tomography. RESULTS: Due to anatomical and (patho-)physiological representation in the 3D printed myocardial perfusion phantom, we were able to acquire 22 dynamic MPI datasets in which 99mTc-labelled tracer kinetics was measured and analyzed using clinical MPI software. After phantom setup optimization, time activity curve analysis was executed for measurements with normal myocardial perfusion settings (1.5 mL/g/min) and with settings containing a regional or global perfusion deficit (0.8 mL/g/min). In these measurements, a specific amount of activated carbon was used to adsorb radiotracer in the simulated myocardial tissue. Such mimicking of myocardial tracer uptake and retention over time satisfactorily matched patient tracer kinetics. For normal perfusion levels, the absolute mean error between computed myocardial blood flow and ground-truth flow settings ranged between 0.1 and 0.4 mL/g/min. CONCLUSION: The presented myocardial perfusion phantom is a first step toward ground-truth validation of multimodal, absolute MPI applications in the clinical setting. Its dedicated and 3D printed design enables tracer kinetic measurement, including time activity curve and potentially compartmental myocardial blood flow analysis

    Impact of Overweight and Obesity on Disease Outcome in the Pediatric Swiss Inflammatory Bowel Disease Cohort.

    Get PDF
    Given the paucity of data, we aimed to assess the impact of obesity on disease activity, complications, and quality of life (QoL) in pediatric inflammatory bowel disease (IBD) patients. Prospective analysis of pediatric IBD patients. Patients were categorized into 4 groups according to the World Health Organization (WHO) child growth standards: obese, overweight, normal weight, and underweight. Three hundred twenty-seven pediatric patients were included (146 with Crohn's disease [CD], 181 with ulcerative colitis of whom 13 [4%] were underweight, 272 [83.2%] had normal weight, 22 [6.7%] were overweight, and 20 [6.1%] were obese). Compared with normal weight patients, obese ulcerative colitis had a significantly higher clinical but not biological disease activity nor severity. Compared with normal weight patients, overweight/obese CD patients did not have higher clinical or biological disease activity nor severity. Perianal abscesses and surgery for this purpose were more frequently observed in overweight/obese CD patients compared with normal weight controls. Overweight/obese IBD patients were similarly hospitalized in the last 12 months compared with normal weight controls. Prevalence of overweight/obesity was 12.8% in pediatric IBD patients. Obesity was not associated with a decrease in disease remission rates nor an increase in the risk of complicated disease progression in IBD pediatric patients, except for the occurrence of perianal abscesses and related surgery in CD patients

    Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study

    Get PDF
    To assess whether absolute mass scores are comparable or differ between identical 64-slice MDCT scanners of the same manufacturer and to compare absolute mass scores to the physical mass and between scan modes using a calcified phantom. A non-moving anthropomorphic phantom with nine calcifications of three sizes and three densities was scanned 30 times on three 64-slice MDCT scanners of manufacturer A and on three 64-slice MDCT scanners of manufacturer B in both sequential and spiral scan mode. The mean mass scores and mass score variabilities of seven calcifications were determined for all scanners; two non-detectable calcifications were omitted. It was analyzed whether identical scanners yielded similar or significantly different mass scores. Furthermore mass scores were compared to the physical mass and mass scores were compared between scan modes. The mass score calibration factor was determined for all scanners. Mass scores obtained on identical scanners were similar for almost all calcifications. Overall, mass score differences between the scanners were small ranging from 1.5 to 3.4% for the total mass scores, and most differences between scanners were observed for high density calcifications. Mass scores were significantly different from the physical mass for almost all calcifications and all scanners. In sequential mode the total physical mass (167.8 mg) was significantly overestimated (+2.3%) for 4 out of 6 scanners. In spiral mode a significant overestimation (+2.5%) was found for system B and a significant underestimation (−1.8%) for two scanners of system A. Mass scores were dependent on the scan mode, for manufacturer A scores were higher in sequential mode and for manufacturer B in spiral mode. For system A using spiral scan mode no differences were found between identical scanners, whereas a few differences were found using sequential mode. For system B the scan mode did not affect the number of different mass scores between identical scanners. Mass scores obtained in the same scan mode are comparable between identical 64-slice CT scanners and identical 64-slice CT scanners on different sites can be used in follow-up studies. Furthermore, for all systems significant differences were found between mass scores and the physical calcium mass; however, the differences were relatively small and consistent

    A new approach to the assessment of lumen visibility of coronary artery stent at various heart rates using 64-slice MDCT

    Get PDF
    Coronary artery stent lumen visibility was assessed as a function of cardiac movement and temporal resolution with an automated objective method using an anthropomorphic moving heart phantom. Nine different coronary stents filled with contrast fluid and surrounded by fat were scanned using 64-slice multi-detector computed tomography (MDCT) at 50–100 beats/min with the moving heart phantom. Image quality was assessed by measuring in-stent CT attenuation and by a dedicated tool in the longitudinal and axial plane. Images were scored by CT attenuation and lumen visibility and compared with theoretical scoring to analyse the effect of multi-segment reconstruction (MSR). An average increase in CT attenuation of 144 ± 59 HU and average diminished lumen visibility of 29 ± 12% was observed at higher heart rates in both planes. A negative correlation between image quality and heart rate was non-significant for the majority of measurements (P > 0.06). No improvement of image quality was observed in using MSR. In conclusion, in-stent CT attenuation increases and lumen visibility decreases at increasing heart rate. Results obtained with the automated tool show similar behaviour compared with attenuation measurements. Cardiac movement during data acquisition causes approximately twice as much blurring compared with the influence of temporal resolution on image quality

    [18F]FDG and [18F]NaF as PET markers of systemic atherosclerosis progression:A longitudinal descriptive imaging study in patients with type 2 diabetes mellitus

    Get PDF
    BACKGROUND: While [18F]-fluordeoxyglucose ([18F]FDG) uptake is associated with arterial inflammation, [18F]-sodium fluoride ([18F]NaF) is a marker for arterial micro-calcification. We aimed to investigate the prospective correlation between both PET markers over time and whether they are prospectively ([18F]FDG) and retrospectively ([18F]NaF) related to progression of systemic arterial disease in a longitudinal study in patients with type 2 diabetes mellitus (T2DM). METHODS: Baseline [18F]FDG PET/Low Dose (LD) Computed Tomography (CT) scans of ten patients with early T2DM without cardiovascular history (70% men, median age 63 years) were compared with five-year follow-up [18F]NaF/LDCT scans. Systemic activity was expressed as mean target-to-background ratio (meanTBR) by dividing the maximal standardized uptake value (SUVmax) of ten arteries by SUVmean of the caval vein. CT-assessed macro-calcifications were scored visually and expressed as calcified plaque (CP) score. Arterial stiffness was assessed with carotid-femoral pulse wave velocity (PWV). Five-year changes were expressed absolutely with delta (Δ) and relatively with %change. RESULTS: Baseline meanTBR[18F]FDG was strongly correlated with five-year follow-up meanTBR[18F]NaF (r = 0.709, P = .022). meanTBR[18F]NaF correlated positively with ΔCPscore, CPscore at baseline, and follow-up (r = 0.845, P = .002 and r = 0.855, P = .002, respectively), but not with %change in CPscore and PWV. CONCLUSION: This proof-of-concept study demonstrated that systemic arterial inflammation is an important pathogenetic factor in systemic arterial micro-calcification development
    corecore