22,826 research outputs found
Optical enhancement of sensitivity in laser Doppler velocity systems
Utilization of optical enhancement techniques prevents loss of light by reflections at the photocathode of a photomultiplier and increases signal detection sensitivity
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor
The Advanced CCD Imaging Spectrometer (ACIS) is one of two focal-plane
instruments on the Chandra X-ray Observatory. During initial radiation-belt
passes, the exposed ACIS suffered significant radiation damage from trapped
soft protons scattering off the x-ray telescope's mirrors. The primary effect
of this damage was to increase the charge-transfer inefficiency (CTI) of the
ACIS 8 front-illuminated CCDs. Subsequently, the Chandra team implemented
procedures to remove the ACIS from the telescope's focus during high-radiation
events: planned protection during radiation-belt transits; autonomous
protection triggered by an on-board radiation monitor; and manual intervention
based upon assessment of space-weather conditions. However, as Chandra's
multilayer insulation ages, elevated temperatures have reduced the
effectiveness of the on-board radiation monitor for autonomous protection. Here
we investigate using the ACIS CCDs themselves as a radiation monitor. We
explore the 10-year database to evaluate the CCDs' response to particle
radiation and to compare this response with other radiation data and
environment models.Comment: 10 pages, 5 figures. To appear in Proc. SPIE vol. 773
Remote measurements of ozone, water vapor and liquid water content, and vertical profiles of temperature in the lower troposphere
Several advanced atmospheric remote sensing systems developed at the Jet Propulsion Laboratory were demonstrated under various field conditions to determine how useful they would be for general use by the California Air Resources Board and local air quality districts. One of the instruments reported on is the Laser Absorption Spectrometer (LAS). It has a pair of carbon dioxide lasers with a transmitter and receiver and can be flown in an aircraft to measure the column abundance of such gases as ozone. From an aircraft, it can be used to rapidly survey a large region. The LAS is usually operated from an aircraft, although it can also be used at a fixed location on the ground. Some tests were performed with the LAS to measure ozone over a 2-km horizontal path. Another system reported on is the Microwave Atmospheric Remote Sensing System (MARS). It is tuned to microwave emissions from water vapor, liquid water, and oxygen molecules (for atmospheric temperature). It can measure water vapor and liquid water in the line-of-sight, and can measure the vertical temperature profile
Older adults' evaluations of the standard and modified pedometer-based Green Prescription
INTRODUCTION: The Green Prescription is a primary care programme designed to increase physical activity in individuals with low activity levels. Older adults tend to engage in insufficient physical activity to obtain health-related gain.
AIM: To examine participantsâ ratings of the Healthy Steps intervention and to assess how participants rated the use of a pedometer-based Green Prescription in aiding their physical activity.
METHODS: In total, 330 community-dwelling older adults who have low levels of activity were randomised to receive either a standard time-based Green Prescription or a modified pedometer-based Green Prescription. Post-intervention, 259 participants completed the participant evaluation questionnaire via postal survey. Data were analysed using descriptive statistics and Chi-squared analyses.
RESULTS: The standard components of the Green Prescription (general practitioner consultations and telephone counselling) received similar and higher ratings across both allocation groups than the use of print materials. A pedometer-based Green Prescription was rated as being helpful in aiding physical activity.
DISCUSSION: This study supports the importance of general practitionersâ initial role in prescribing physical activity for older adults and of ongoing telephone support for longer-term adherence. Incorporating a pedometer can be effective in helping low-active older adults initiate and maintain regular physical activity
Using ACIS on the Chandra X-ray Observatory as a particle radiation monitor II
The Advanced CCD Imaging Spectrometer is an instrument on the Chandra X-ray
Observatory. CCDs are vulnerable to radiation damage, particularly by soft
protons in the radiation belts and solar storms. The Chandra team has
implemented procedures to protect ACIS during high-radiation events including
autonomous protection triggered by an on-board radiation monitor. Elevated
temperatures have reduced the effectiveness of the on-board monitor. The ACIS
team has developed an algorithm which uses data from the CCDs themselves to
detect periods of high radiation and a flight software patch to apply this
algorithm is currently active on-board the instrument. In this paper, we
explore the ACIS response to particle radiation through comparisons to a number
of external measures of the radiation environment. We hope to better understand
the efficiency of the algorithm as a function of the flux and spectrum of the
particles and the time-profile of the radiation event.Comment: 10 pages, 5 figures, to be published in Proc. SPIE 8443, "Space
Telescopes and Instrumentation 2012: Ultraviolet to Gamma Ray
The changing patterns of group politics in Britain
Two interpretations of ways in which group politics in Britain have presented challenges to democracy are reviewed: neo-corporatism or pluralistic stagnation and the rise of single issue interest groups. The disappearance of the first paradigm created a political space for the second to emerge. A three-phase model of group activity is developed: a phase centred around production interests, followed by the development of broadly based 'other regarding' groups, succeeded by fragmented, inner directed groups focusing on particular interests. Explanations of the decay of corporatism are reviewed. Single issue group activity has increased as party membership has declined and is facilitated by changes in traditional media and the development of the internet. Such groups can overload the policy-making process and frustrate depoliticisation. Debates about the constitution and governance have largely ignored these issues and there is need for a debate
Advanced high temperature static strain sensor development
An examination was made into various techniques to be used to measure static strain in gas turbine liners at temperatures up to 1150 K (1600 F). The methods evaluated included thin film and wire resistive devices, optical fibers, surface acoustic waves, the laser speckle technique with a heterodyne readout, optical surface image and reflective approaches and capacitive devices. A preliminary experimental program to develop a thin film capacitive device was dropped because calculations showed that it would be too sensitive to thermal gradients. In a final evaluation program, the laser speckle technique appeared to work well up to 1150 K when it was used through a relatively stagnant air path. The surface guided acoustic wave approach appeared to be interesting but to require too much development effort for the funds available. Efforts to develop a FeCrAl resistive strain gage system were only partially successful and this part of the effort was finally reduced to a characterization study of the properties of the 25 micron diameter FeCrAl (Kanthal A-1) wire. It was concluded that this particular alloy was not suitable for use as the resistive element in a strain gage above about 1000 K
Precompact noncompact reflexive abelian groups
We present a series of examples of precompact, noncompact, reflexive
topological Abelian groups. Some of them are pseudocompact or even countably
compact, but we show that there exist precompact non-pseudocompact reflexive
groups as well. It is also proved that every pseudocompact Abelian group is a
quotient of a reflexive pseudocompact group with respect to a closed reflexive
pseudocompact subgroup
Status of BetaCage: an Ultra-sensitive Screener for Surface Contamination
BetaCage, a gaseous neon time-projection chamber, has been proposed as a viable screener for emitters of low-energy alphas and electrons to which commercial radioactivity counting techniques are insensitive. Using radiopure materials for construction, active and passive shielding from extrinsic backgrounds, large counting area and minimal detector mass, BetaCage will be able to achieve sensitivities of 10^(â5) counts keV^(â1) kg^(â1) day^(â1) in a few days of running time. We report on progress in prototype development work since the last meeting of this workshop
- âŠ