44 research outputs found

    Low Resolution Structure of Mitochondrial Rho Protein via SAXS

    Get PDF

    Sub-millisecond time-resolved SAXS using a continuous-flow mixer and X-ray micro-beam

    Get PDF
    Small-angle X-ray scattering (SAXS) is a well established technique to probe the nanoscale structure and interactions in soft matter. It allows one to study the structure of native particles in near physiological environments and to analyze structural changes in response to variations in external conditions. The combination of microfluidics and SAXS provides a powerful tool to investigate dynamic processes on a molecular level with sub-millisecond time resolution. Reaction kinetics in the sub-millisecond time range has been achieved using continuous-flow mixers manufactured using micromachining techniques. The time resolution of these devices has previously been limited, in part, by the X-ray beam sizes delivered by typical SAXS beamlines. These limitations can be overcome using optics to focus X-rays to the micrometer size range providing that beam divergence and photon flux suitable for performing SAXS experiments can be maintained. Such micro-SAXS in combination with microfluidic devices would be an attractive probe for time-resolved studies. Here, the development of a high-duty-cycle scanning microsecond-timeresolution SAXS capability, built around the Kirkpatrick–Baez mirror-based microbeam system at the Biophysics Collaborative Access Team (BioCAT) beamline 18ID at the Advanced Photon Source, Argonne National Laboratory, is reported. A detailed description of the microbeam small-angle-scattering instrument, the turbulent flow mixer, as well as the data acquisition and control and analysis software is provided. Results are presented where this apparatus was used to study the folding of cytochrome c. Future prospects for this technique are discussed

    Helicobacter pylori and Epstein–Barr Virus Co-Infection in Gastric Disease: What Is the Correlation with p53 Mutation, Genes Methylation and Microsatellite Instability in a Cohort of Sicilian Population?

    Get PDF
    Genetic predisposition, environmental factors, and infectious agents interact in the development of gastric diseases. Helicobacter pylori (Hp) and Epstein–Barr virus (EBV) infection has recently been shown to be correlated with these diseases. A cross-sectional study was performed on 100 hospitalized Italian patients with and without gastric diseases. The patients were stratified into four groups. Significant methylation status differences among CDH1, DAPK, COX2, hMLH1 and CDKN2A were observed for coinfected (Hp-EBV group) patients; particularly, a significant presence of COX2 (p = 0.0179) was observed. For microsatellite instability, minor stability was described in the Hp-HBV group (69.23%, p = 0.0456). Finally, for p53 mutation in the EBV group, exon 6 was, significantly, most frequent in comparison to others (p = 0.0124), and in the Hp-EBV group exon 8 was, significantly, most frequent in comparison to others (p < 0.0001). A significant positive relationship was found between patients with infection (Hp, EBV or both) and p53 mutation (rho = 0.383, p = 0.0001), methylation status (rho = 0.432, p < 0.0001) and microsatellite instability (rho = 0.285, p = 0.004). Finally, we observed among infection and methylation status, microsatellite instability, and p53 mutation a significant positive relationship only between infection and methylation status (OR = 3.78, p = 0.0075) and infection and p53 mutation (OR = 6.21, p = 0.0082). According to our analysis, gastric disease in the Sicilian population has different pathways depending on the presence of various factors, including infectious agents such as Hp and EBV and genetic factors of the subject

    Modulation of frustration in folding by sequence permutation

    Get PDF
    Folding of globular proteins can be envisioned as the contraction of a random coil unfolded state toward the native state on an energy surface rough with local minima trapping frustrated species. These substructures impede productive folding and can serve as nucleation sites for aggregation reactions. However, little is known about the relationship between frustration and its underlying sequence determinants. Chemotaxis response regulator Y (CheY), a 129-amino acid bacterial protein, has been shown previously to populate an off-pathway kinetic trap in the microsecond time range. The frustration has been ascribed to premature docking of the N- and C-terminal subdomains or, alternatively, to the formation of an unproductive local-in-sequence cluster of branched aliphatic side chains, isoleucine, leucine, and valine (ILV). The roles of the subdomains and ILV clusters in frustration were tested by altering the sequence connectivity using circular permutations. Surprisingly, the stability and buried surface area of the intermediate could be increased or decreased depending on the location of the termini. Comparison with the results of small-angle X-ray-scattering experiments and simulations points to the accelerated formation of a more compact, on-pathway species for the more stable intermediate. The effect of chain connectivity in modulating the structures and stabilities of the early kinetic traps in CheY is better understood in terms of the ILV cluster model. However, the subdomain model captures the requirement for an intact N-terminal domain to access the native conformation. Chain entropy and aliphatic-rich sequences play crucial roles in biasing the early events leading to frustration in the folding of CheY

    Not all KIT 557/558 codons mutations have the same prognostic influence on recurrence-free survival: breaking the exon 11 mutations in gastrointestinal stromal tumors (GISTs)

    Get PDF
    Background: Although the gastrointestinal stromal tumor (GIST) genotype is not currently included in risk-stratification systems, a growing body of evidence shows that the pathogenic variant (PV) type and codon location hold a strong prognostic influence on recurrence-free survival (RFS). This information has particular relevance in the adjuvant setting, where an accurate prognostication could help to better identify high-risk tumors and guide clinical decision-making. Materials and Methods: Between January 2005 and December 2020, 96 patients with completely resected GISTs harboring a KIT proto-oncogene receptor tyrosine kinase (KIT) exon 11 PV were included in the study. We analyzed the type and codon location of the PV according to clinicopathological characteristics and clinical outcome; the metastatic sites in relapsed patients were also investigated. Results: Tumors harboring a KIT exon 11 deletion or deletion/insertion involving the 557 and/or 558 codons, showed a more aggressive clinical behavior compared with tumors carrying deletion/deletion/insertion in other codons, or tumors with duplication/insertion/single-nucleotide variant (SNV) (7-year RFS: 50% versus 73.1% versus 88.2%, respectively; p < 0.001). Notably, among 18 relapsed patients with 557 and/or 558 deletion or deletion/insertion, 14 patients (77.8%) harbored deletions simultaneously involving 557 and 558 codons, while only 4 patients (22.2%) harbored deletions involving only 1 of the 557/558 codons. Thus, when 557 or 558 deletions occurred separately, the tumor showed a prognostic behavior similar to the GIST carrying deletions outside the 557/558 position. Remarkably, patients with GISTs stratified as intermediate risk, but carrying the 557/558 deletion, showed a similar outcome to the high-risk patients with tumors harboring deletions in codons other than 557/558, or duplication/insertion/SNV. Conclusion: Our data support the inclusion of the PV type and codon location in routine risk prediction models, and suggest that intermediate-risk patients whose GISTs harbor 557/558 deletions may also need to be treated with adjuvant imatinib like the high-risk patients

    Development of crystal optics for Multi-Projection X-ray Imaging for synchrotron and XFEL sources

    Full text link
    X-ray Multi-Projection Imaging (XMPI) is an emerging technology that allows for the acquisition of millions of 3D images per second in samples opaque to visible light. This breakthrough capability enables volumetric observation of fast stochastic phenomena, which were inaccessible due to the lack of a volumetric X-ray imaging probe with kHz to MHz repetition rate. These include phenomena of industrial and societal relevance such as fractures in solids, propagation of shock waves, laser-based 3D printing, or even fast processes in the biological domain. Indeed, the speed of traditional tomography is limited by the shear forces caused by rotation, to a maximum of 1000 Hz in state-of-the-art tomography. Moreover, the shear forces can disturb the phenomena in observation, in particular with soft samples or sensitive phenomena such as fluid dynamics. XMPI is based on splitting an X-ray beam to generate multiple simultaneous views of the sample, therefore eliminating the need for rotation. The achievable performances depend on the characteristics of the X-ray source, the detection system, and the X-ray optics used to generate the multiple views. The increase in power density of the X-ray sources around the world now enables 3D imaging with sampling speeds in the kilohertz range at synchrotrons and megahertz range at X-ray Free-Electron Lasers (XFELs). Fast detection systems are already available, and 2D MHz imaging was already demonstrated at synchrotron and XFEL. In this work, we explore the properties of X-ray splitter optics and XMPI schemes that are compatible with synchrotron insertion devices and XFEL X-ray beams. We describe two possible schemes designed to permit large samples and complex sample environments. Then, we present experimental proof of the feasibility of MHz-rate XMPI at the European XFEL.Comment: 47 pages, 17 figure

    Rapid sample delivery for megahertz serial crystallography at X-ray FELs

    Get PDF
    Liquid microjets are a common means of delivering protein crystals to the focus of X-ray free-electron lasers (FELs) for serial femtosecond crystallography measurements. The high X-ray intensity in the focus initiates an explosion of the microjet and sample. With the advent of X-ray FELs with megahertz rates, the typical velocities of these jets must be increased significantly in order to replenish the damaged material in time for the subsequent measurement with the next X-ray pulse. This work reports the results of a megahertz serial diffraction experiment at the FLASH FEL facility using 4.3 nm radiation. The operation of gas-dynamic nozzles that produce liquid microjets with velocities greater than 80 m s-1 was demonstrated. Furthermore, this article provides optical images of X-ray-induced explosions together with Bragg diffraction from protein microcrystals exposed to trains of X-ray pulses repeating at rates of up to 4.5 MHz. The results indicate the feasibility for megahertz serial crystallography measurements with hard X-rays and give guidance for the design of such experiments

    Zu den Wurzeln der Modernen Architektur, Teil I

    Get PDF
    Modern emerging technologies, such as additive manufacturing, bioprinting, and new material production, require novel metrology tools to probe fundamental high-speed dynamics happening in such systems. Here we demonstrate the application of the megahertz (MHz) European X-ray Free-Electron Laser (EuXFEL) to image the fast stochastic processes induced by a laser on water-filled capillaries with micrometer-scale spatial resolution. The EuXFEL provides superior contrast and spatial resolution compared to equivalent state-of-the-art synchrotron experiments. This work opens up new possibilities for the characterization of MHz stochastic processes on the nanosecond to microsecond time scales with object velocities up to a few kilometers per second using XFEL sources

    Neutralizing antibodies to Omicron after the fourth SARS-CoV-2 mRNA vaccine dose in immunocompromised patients highlight the need of additional boosters

    Get PDF
    IntroductionImmunocompromised patients have been shown to have an impaired immune response to COVID-19 vaccines.MethodsHere we compared the B-cell, T-cell and neutralizing antibody response to WT and Omicron BA.2 SARS-CoV-2 virus after the fourth dose of mRNA COVID-19 vaccines in patients with hematological malignancies (HM, n=71), solid tumors (ST, n=39) and immune-rheumatological (IR, n=25) diseases. The humoral and T-cell responses to SARS-CoV-2 vaccination were analyzed by quantifying the anti-RBD antibodies, their neutralization activity and the IFN-Îł released after spike specific stimulation.ResultsWe show that the T-cell response is similarly boosted by the fourth dose across the different subgroups, while the antibody response is improved only in patients not receiving B-cell targeted therapies, independent on the pathology. However, 9% of patients with anti-RBD antibodies did not have neutralizing antibodies to either virus variants, while an additional 5.7% did not have neutralizing antibodies to Omicron BA.2, making these patients particularly vulnerable to SARS-CoV-2 infection. The increment of neutralizing antibodies was very similar towards Omicron BA.2 and WT virus after the third or fourth dose of vaccine, suggesting that there is no preferential skewing towards either virus variant with the booster dose. The only limited step is the amount of antibodies that are elicited after vaccination, thus increasing the probability of developing neutralizing antibodies to both variants of virus.DiscussionThese data support the recommendation of additional booster doses in frail patients to enhance the development of a B-cell response directed against Omicron and/or to enhance the T-cell response in patients treated with anti-CD20

    Développement d'un instrument de mélange de gouttes pour jets d'encre synchronisés pour expérience de diffusion centrale et de diffraction de rayons X

    No full text
    Microfluidics is the science and technology of systems that process or manipulate small (10-9 to 10-18 litres) amounts of fluids. (Whitesides 2006) The “lab-on-a-chip” concept is shrinking a chemical or biochemical laboratory to the dimension of a microchip (Knight 2002) which is getting in the range of functional biological units and is generating an increasing interest in mimicking nature. The practical advantages of microfluidics are a substantial reduction of reagent consumption and a reduction of timescales for diffusion processes which is of interest for studying fast processes such as conformational changes of proteins. The principal aim of my thesis project was to develop “in-flight” microdrop mixing by crossed inkjets in analogy to “in-channel” microfluidic mixing techniques. (Ottino and Wiggins 2004) Microdrop technology allows significantly reducing sample volumes as compared to microfluidic technology and wall effects, such as shearing or aggregation, can be avoided.Le but principal de mon projet de thèse était de développer un instrument de mélange en vol de microgouttes pour jets d'encre synchronisés. Les microgouttes balistiques passent voir l'air peut être pensé comme des navires de réaction avec des volumes en bas à la pl-gamme. Les réactifs restent limités dans les microgouttes pendant leur trajectoire. Les effets de tondage induits de la présence murale ne jouent pas de rôle; bien que la compression mécanique de la solution pendant le processus d'éjection puisse influencer l'intégrité structurelle de protéines fragiles. J'ai exploré dans ma thèse pour la première fois la combinaison de microgouttes balistiques avec des techniques de microdiffusion stroboscopique. L'effort instrumental principal était donc de développer une installation stable avec deux jets d'encre pour étudier mélange de microgouttes en vol à ligne de lumière ID13, ESRF utilisant expériences de diffusion centrale et de diffraction de rayons X stroboscopique. J'ai utilisé ces techniques pour étudier la paraffine liquide en vol et des microgouttes de cytochrome C et la coalescence de microgouttes de cytochrome C avec des microgouttes de tampon de Na-acetate. J'ai également exécuté des expériences exploratoires de diffraction de rayons X à la ligne de lumière ID13 sur des microgouttes de paraffine solide déposés sur des surfaces et la diffraction dépendante de la température sur le solide de paraffine pour calibrer les données stroboscopiques. Des expériences statiques de diffusion centrale ont été exécutées à la ligne de lumière ID02 pour obtenir des courbes de la référence pour les états de conformation de solutions du cytochrome C
    corecore