380 research outputs found

    Quantitative T1 mapping of the normal brain from early infancy to adulthood

    Get PDF
    Abstract Background Quantitative mapping of MRI relaxation times is expected to uncover pathological processes in the brain more subtly than standard MRI techniques with weighted contrasts. So far, however, most mapping techniques suffer from a long measuring time, low spatial resolution or even sensitivity to magnetic field inhomogeneity. Objective To obtain T1 relaxation times of the normal brain from early infancy to adulthood using a novel technique for fast and accurate T1 mapping at high spatial resolution. Materials and methods We performed whole-brain T1 mapping within less than 3 min in 100 patients between 2 months and 18 years of age with normal brain at a field strength of 3 T. We analyzed T1 relaxation times in several gray-matter nuclei and white matter. Subsequently, we derived regression equations for mean value and confidence interval. Results T1 relaxation times of the pediatric brain rapidly decrease in all regions within the first 3 years of age, followed by a significantly weaker decrease until adulthood. These characteristics are more pronounced in white matter than in deep gray matter. Conclusion Regardless of age, quantitative T1 mapping of the pediatric brain is feasible in clinical practice. Normal age- dependent values should contribute to improved discrimination of subtle intracerebral alterations

    Endurance of quantum coherence due to particle indistinguishability in noisy quantum networks

    Get PDF
    Quantum coherence, the physical property underlying fundamental phenomena such as multi-particle interference and entanglement, has emerged as a valuable resource upon which modern technologies are founded. In general, the most prominent adversary of quantum coherence is noise arising from the interaction of the associated dynamical system with its environment. Under certain conditions, however, the existence of noise may drive quantum and classical systems to endure intriguing nontrivial effects. In this vein, here we demonstrate, both theoretically and experimentally, that when two indistinguishable non-interacting particles co-propagate through quantum networks affected by non-dissipative noise, the system always evolves into a steady state in which coherences accounting for particle indistinguishabilty perpetually prevail. Furthermore, we show that the same steady state with surviving quantum coherences is reached even when the initial state exhibits classical correlations.Comment: arXiv admin note: substantial text overlap with arXiv:1709.0433

    Scalable quantum tomography in a photonic chip

    Full text link
    © 2017 IEEE. We formulate a method of quantum tomography that scales linearly with the number of photons and involves only one optical transformation. We demonstrate it experimentally for two-photon entangled states using a special photonic chip

    Real-time magnetic resonance imaging in pediatric radiology — new approach to movement and moving children

    Get PDF
    The recent development of highly undersampled radial gradient echo sequences in combination with nonlinear inverse image reconstruction now allows for MRI examinations in real time. Image acquisition times as short as 20 ms yield MRI videos with rates of up to 50 frames per second with spin density, T1- and T2-type contrast. The addition of an initial 180° inversion pulse achieves accurate T1 mapping within only 4 s. These technical advances promise specific advantages for studies of infants and young children by eliminating the need for sedation or anesthesia. Our preliminary data demonstrate new diagnostic opportunities ranging from dynamic studies of speech and swallowing processes and body movements to a rapid volumetric assessment of brain cerebrospinal fluid spaces in only few seconds. Real-time MRI of the heart and blood flow can be performed without electrocardiogram gating and under free breathing. The present findings support the idea that real-time MRI will complement existing methods by providing long-awaited diagnostic options for patients in early childhood. Major advantages are the avoidance of sedation or anesthesia and the yet unexplored potential to gain insights into arbitrary body functions

    Outpacing movement — ultrafast volume coverage in neuropediatric magnetic resonance imaging

    Get PDF
    Background Conventional MRI sequences are often affected in neuropediatric imaging by unavoidable movements. Therefore, children younger than 6 years usually have to be examined under sedation/anesthesia. A new real-time MRI technique with automatic slice advancement allows for motion-robust T2-weighted volume coverage of the whole brain within a few seconds in adults. Objective To evaluate to which extent the new volume coverage method can be used to visualize cerebrospinal fluid and reduce the need for anesthesia in children. Materials and methods We assessed 30 children ages 6 years and younger with suspected or proven hydrocephalus, hygroma or macrocephalus using volume coverage sequences with 20 slices per second in three planes. If necessary, a parent was placed in the bore together with the child for calming and gentle immobilization. We compared visualization of cerebrospinal fluid spaces and course of the shunt catheter in volume coverage sequences vs. fast spin-echo sequences. Results The clinical issue could be sufficiently assessed in all children with use of volume coverage sequences, whereas conventional fast spin-echo sequences performed moderately to poorly. Visualization of the tip of a shunt failed in 16% of volume coverage scans and 27% of turbo spin-echo scans. A subsequent examination under anesthesia was never necessary. None of the examinations had to be stopped prematurely. Conclusion The motion-robust volume coverage sequences with T2-type contrast can be used to avoid sedation of children in the evaluation of cerebrospinal fluid spaces, even in the presence of vigorous motion. For other indications and contrasts, the technique must still be evaluated

    Non-Adiabatic Electronic and Vibrational Ring-Opening Dynamics resolved with Attosecond Core-Level Spectroscopy

    Full text link
    Non-adiabatic dynamics and conical intersections play a central role in the chemistry of most polyatomic molecules, ranging from isomerization to heterocyclic ring opening and avoided photo-damage of DNA. Studying the underpinning correlated dynamics of electronic and nuclear wave packets is a major challenge in real-time and, many times involves optically dark transient states. We show that attosecond core-level spectroscopy reveals the pathway dynamics of neutral furan across its conical intersections and dark states. Our method measures electronic-nuclear correlations to detect the dephasing of electronic coherence due to nuclear motion and identifies the ring-opened isomer as the dominant product. These results demonstrate the efficacy of attosecond core level spectroscopy as a potent method to investigate the real-time dynamics of photochemical reaction pathways in complex molecular systems

    X-Ray Microscopy of Spin Wave Focusing using a Fresnel Zone Plate

    Full text link
    Magnonics, i.e. the artificial manipulation of spin waves, is a flourishing field of research with many potential uses in data processing within reach. Apart from the technological applications the possibility to directly influence and observe these types of waves is of great interest for fundamental research. Guidance and steering of spin waves has been previously shown and lateral spin wave confinement has been achieved. However, true spin wave focusing with both lateral confinement and increase in amplitude has not been shown before. Here, we show for the first time spin wave focusing by realizing a Fresnel zone plate type lens. Using x-ray microscopy we are able to directly image the propagation of spin waves into the nanometer sized focal spot. Furthermore, we observe that the focal spot can be freely moved in a large area by small variations of the bias field. Thus, this type of lens provides a steerable intense nanometer sized spin wave source. Potentially, this could be used to selectively illuminate magnonic devices like nano oscillators with a steerable spin wave beam

    Oscillations in Quantum Entanglement During Rescattering

    Full text link
    We study the time evolution of quantum entanglement between an electron and its parent ion during the rescattering due to a strong few-cycle laser pulse. Based on a simple one-dimensional model, we compute the Neumann entropy during the process for several values of the carrier-envelope phase. The local maxima of the oscillations in the Neumann entropy coincide with the zero crossings of the electric field of the laser pulse. We employ the Wigner function to qualitatively explain the quantum dynamics of rescattering in the phase space.Comment: 2 page
    • …
    corecore