334 research outputs found

    Experimental investigation of vortex breakdown in a coaxial swirling jet with a density difference

    Get PDF
    In this work we experimentally investigate the behavior of stable vortex breakdown taking place in a coaxial swirling jet with a density difference, highlighting the effect of the outer jet on the height of the stagnation point. With increasing bulk flow velocity of the outer jet, the degree of flow divergence decreases, resulting in an increase in the height of the stagnation point. This is due to a significant increase in the mean axial velocity along the centerline of the jet, which is clearly shown by particle image velocimetry (PIV). We proposed an equation to physically explain the height of the stagnation point in a coaxial swirling jet with a density difference undergoing vortex breakdown, by considering an estimate of the momentum balance in the flow, based on a simplified Navier–Stokes equation for coaxial jets with coannular flow. Even though the effect of the density difference on the height of the stagnation point is overestimated by the proposed equation, the increase with respect to the Reynolds number of the outer jet observed experimentally is in reasonably good qualitative agreement with the trend predicted by the theoretical model

    Construction and Calibration of Optically Efficient LCD-based Multi-Layer Light Field Displays

    Get PDF
    Near-term commercial multi-view displays currently employ ray-based 3D or 4D light field techniques. Conventional approaches to ray-based display typically include lens arrays or heuristic barrier patterns combined with integral interlaced views on a display screen such as an LCD panel. Recent work has placed an emphasis on the co-design of optics and image formation algorithms to achieve increased frame rates, brighter images, and wider fields-of-view using optimization-in-the-loop and novel arrangements of commodity LCD panels. In this paper we examine the construction and calibration methods of computational, multi-layer LCD light field displays. We present several experimental configurations that are simple to build and can be tuned to sufficient precision to achieve a research quality light field display. We also present an analysis of moiré interference in these displays, and guidelines for diffuser placement and display alignment to reduce the effects of moiré. We describe a technique using the moiré magnifier to fine-tune the alignment of the LCD layers

    Italy-Japan agreement and discrepancies in diagnosis of superficial gastric lesions.

    Get PDF
    The agreement between Italian and Japanese endoscopists and pathologists on endoscopic and histopathological diagnoses of superficial gastric lesions is verified with the use of Paris and Vienna classifications. The correlations between Paris endoscopic types and Vienna histopathological categories is high in both the independent Italian and Japanese evaluations. However, the agreement between Italian and Japanese endoscopists is moderate due to the difficult evaluation of the height of the lesions, in particular when they are mixed. The agreement on the size of the lesions is fairly good. The probability of the same allocation to the Vienna categories of a single case is 87 per cent, disagreements remaining in dysplasia grading, between dysplasia, not only high-grade but also low-grade, and in situ carcinoma, and on cancer invasion of the lamina propria. The results indicate that use of the Paris and Vienna classifications has reduced the discrepancies between Western and Japanese endoscopists and pathologists in the diagnosis of these lesions

    A Western single-center experience with endoscopic submucosal dissection for early gastrointestinal cancers

    No full text
    Endoscopic submucosal dissection (ESD) has gained worldwide acceptance as a treatment for early gastrointestinal cancers (EGICs). However, the management of these tumors in the Western world is still mainly surgical. Our aim was to evaluate the safety and feasibility of ESD at a European center. Based on the knowledge transferred by one of the most experienced Japanese institutions, we conducted a pilot study on 25 consecutive patients with EGICs located in the esophagus (n = 3), stomach (n = 7), duodenum (n = 1), and colon (n = 14) at our tertiary center over a 2-year-period. The main outcome measurements were complete (R0) resection, as well as en-bloc resection and the management of complications. The R0 and en-bloc resection rates were 100% and 84%, respectively. There were three cases of bleeding and five cases of perforation. With a median follow up of 18 months, two recurrences were observed. We conclude that ESD for early esophageal and gastric cancers is feasible and effective, while colonic ESD requires more expertise

    Clinicopathological characteristics and treatment strategies in early gastric cancer: a retrospective cohort study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Both endoscopic and surgical approaches are employed in the treatment of early gastric cancer (EGC). The aim of this study was to establish appropriate treatment strategies for early gastric cancer.</p> <p>Methods</p> <p>We retrospectively examined clinicopathological data of EGC patients who had undergone surgery.</p> <p>Results</p> <p>A total of 327 patients (204 males and 123 females, mean age 63.2 years) were eligible for inclusion in the study. The median follow-up period was 31 months. Of 161 mucosal (pT1a) tumors, 87 were mainly undifferentiated and 110 had an undifferentiated component. Four patients with pT1a tumors had lymph node metastases; all these tumors were signet-ring cell carcinomas and were macroscopic type 0-IIc with ulceration, and only one of them had lymphatic invasion. Among patients with submucosal tumors, four of 43 patients with pT1b1 tumors and 37 of 123 patients with pT1b2 tumors had nodal metastases. Lymph node metastases were significantly higher in mixed undifferentiated type group than differentiated type group for both groups, pT1a-pT1b1 (p = 0.0251) and pT1b2 (p = 0.0430) subgroups. Only four of 45 patients with nodal metastases were diagnosed preoperatively by computed tomography (sensitivity 8.9%, specificity 96.2%). Nine patients with pT1b tumors had recurrence after surgery, and died. The sites of initial recurrence were liver, bone, peritoneum, distant nodes, and the surgical anastomosis.</p> <p>Conclusions</p> <p>The incidence of nodal metastases was approximately 5% in undifferentiated type mucosal (pT1a) tumors, and higher in submucosal (pT1b) tumors. The sensitivity of preoperative diagnosis of nodal metastases in EGC using computed tomography was relatively low in this study. Therefore at present surgery with adequate lymphadenectomy should be performed as curative treatment for undifferentiated type EGC.</p

    Usefulness and safety of 0.4% sodium hyaluronate solution as a submucosal fluid "cushion" for endoscopic resection of colorectal mucosal neoplasms: A prospective multi-center open-label trial

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Sodium hyaluronate (SH) solution has been used for submucosal injection in endoscopic resection to create a long-lasting submucosal fluid "cushion". Recently, we proved the usefulness and safety of 0.4% SH solution in endoscopic resection for gastric mucosal tumors. To evaluate the usefulness of 0.4% SH as a submucosal injection solution for colorectal endoscopic resection, we conducted an open-label clinical trial on six referral hospitals in Japan.</p> <p>Methods</p> <p>A prospective multi-center open-label study was designed. A total of 41 patients with 5–20 mm neoplastic lesions localized in the colorectal mucosa at six referral hospitals in Japan in a single year period from December 2002 to November 2003 were enrolled and underwent endoscopic resection with SH. The usefulness of 0.4% SH was assessed by the <it>en bloc </it>complete resection and the formation and maintenance of mucosal lesion-lifting during endoscopic resection. Safety was evaluated by analyzing adverse events during the study period.</p> <p>Results</p> <p>The usefulness rate was high (82.5%; 33/40). The following secondary outcome measures were noted: 1) steepness of mucosal lesion-lifting, 75.0% (30/40); 2) intraoperative complications, 10.0% (4/40); 3) time required for mucosal resection, 6.7 min; 4) volume of submucosal injection, 6.8 mL and 5) ease of mucosal resection, 87.5% (35/40). Two adverse events of bleeding potentially related to 0.4% SH were reported.</p> <p>Conclusion</p> <p>Using 0.4% SH solution enabled sufficient lifting of a colorectal intramucosal lesion during endoscopic resection, reducing the need for additional injections and the risk of perforation. Therefore, 0.4% SH may contribute to the reduction of complications and serve as a promising submucosal injection solution due to its potentially superior safety in comparison to normal saline solution.</p

    Management of esophageal stricture after complete circular endoscopic submucosal dissection for superficial esophageal squamous cell carcinoma

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Endoscopic submucosal dissection (ESD) permits removal of esophageal epithelial neoplasms <it>en bloc</it>, but is associated with esophageal stenosis, particularly when ESD involves the entire circumference of the esophageal lumen. We examined the effectiveness of systemic steroid administration for control of postprocedural esophageal stricture after complete circular ESD.</p> <p>Methods</p> <p>Seven patients who underwent wholly circumferential ESD for superficially extended esophageal squamous cell carcinoma were enrolled in this study. In 3 patients, prophylactic endoscopic balloon dilatation (EBD) was started on the third post-ESD day and was performed twice a week for 8 weeks. In 4 patients, oral prednisolone was started with 30 mg daily on the third post-ESD day, tapered gradually (daily 30, 30, 25, 25, 20, 15, 10, 5 mg for 7 days each), and then discontinued at 8 weeks. EBD was used as needed whenever patients complained of dysphagia.</p> <p>Results</p> <p><it>En bloc </it>ESD with tumor-free margins was safely achieved in all cases. Patients in the prophylactic EBD group required a mean of 32.7 EBD sessions; the postprocedural stricture was dilated up to 18 mm in diameter in these patients. On the other hand, systemic steroid administration substantially reduced or eliminated the need for EBD. Corticosteroid therapy was not associated with any adverse events. Post-ESD esophageal stricture after complete circular ESD was persistent, requiring multiple EBD sessions.</p> <p>Conclusions</p> <p>Use of oral prednisolone administration may be an effective treatment strategy for reducing post-ESD esophageal stricture after complete circular ESD.</p
    corecore