18 research outputs found

    Second-generation colon capsule endoscopy compared with colonoscopy

    Get PDF
    Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >/=6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging

    Safety and Feasibility of Using the Second-Generation Pillcam Colon Capsule to Assess Active Colonic Crohn's Disease

    No full text
    The second-generation Pillcam Colon Capsule Endoscope (PCCE-2; Given Imaging Ltd, Yoqneam, Israel) is an ingestible capsule for visualization of the colon. We performed a multicenter pilot study to assess its safety and feasibility in evaluating the severity of Crohn's disease (CD). In a prospective study, 40 patients with active colonic CD underwent PCCE-2 and optical colonoscopy procedures. Using both techniques, we generated values for the Crohn's Disease Endoscopic Index of Severity (CDEIS), the Simple Endoscopic Score for CD, and global evaluation of lesion severity. In the first stage of the study, we calculated the correlation between PCCE-2 and optical colonoscopy scores. In the second stage, we performed interobserver agreement analysis for a random subset of 20 PCCE-2 recordings, graded in duplicate by 2 independent readers. There was substantial agreement between PCCE-2 and optical colonoscopy in the measurement of the CDEIS (intraclass correlation coefficient [ICC], 0.65; 95% confidence interval [CI], 0.43-0.80). There was substantial interobserver agreement between 2 independent PCCE-2 readers for the CDEIS (ICC, 0.67; 95% CI, 0.35-0.86) and the Simple Endoscopic Score for CD (ICC, 0.66; 95% CI, 0.32-0.85). However, the PCCE-2 scoring systematically underestimated the severity of disease compared with optical colonoscopy; based on our results, PCCE-2 detected colonic ulcerations with 86% sensitivity and 40% specificity. No adverse events were observed and PCCE-2 was better tolerated than colonoscopy. PCCE-2 is feasible, safe, and well tolerated for the assessment of mucosal CD activity in selected populations. Larger studies are needed to assess its operating characteristics further. European clinical trials database number: 2014-003854-1

    GLIM Criteria for the Diagnosis of Malnutrition: A Consensus Report From the Global Clinical Nutrition Community

    Get PDF
    Background: This initiative aims to build a global consensus around core diagnostic criteria for malnutrition in adults in clinical settings. Methods: The Global Leadership Initiative on Malnutrition (GLIM) was convened by several of the major global clinical nutrition societies. Empirical consensus was reached through a series of face-to-face meetings, telephone conferences, and e-mail communications. Results: A 2-step approach for the malnutrition diagnosis was selected, that is, first screening to identify at risk status by the use of any validated screening tool, and second, assessment for diagnosis and grading the severity of malnutrition. The malnutrition criteria for consideration were retrieved from existing approaches for screening and assessment. Potential criteria were subjected to a ballot among GLIM participants that selected 3 phenotypic criteria (non-volitional weight loss, low body mass index, and reduced muscle mass) and 2 etiologic criteria (reduced food intake or assimilation, and inflammation or disease burden). To diagnose malnutrition at least 1 phenotypic criterion and 1 etiologic criterion should be present. Phenotypic metrics for grading severity are proposed. It is recommended that the etiologic criteria be used to guide intervention and anticipated outcomes. The recommended approach supports classification of malnutrition into four etiology-related diagnosis categories. Conclusions: A consensus scheme for diagnosing malnutrition in adults in clinical settings on a global scale is proposed. Next steps are to secure endorsements from leading nutrition professional societies, to identify overlaps with syndromes like cachexia and sarcopenia, and to promote dissemination, validation studies, and feedback. The construct should be re-considered every 3\u20135 years

    Consecutive fecal calprotectin measurements to predict relapse in patients with ulcerative colitis receiving infliximab maintenance therapy.

    Full text link
    BACKGROUND: This study examined whether fecal calprotectin can be used in daily practice as a marker to monitor patients with ulcerative colitis (UC) receiving infliximab maintenance therapy. METHODS: This prospective multicenter study enrolled adult patients with UC in clinical remission under infliximab maintenance therapy. Fecal calprotectin levels were measured every 4 weeks. Sigmoidoscopies were performed at inclusion and at study end. Relapse was defined as a clinical need for change in treatment or an endoscopic Mayo subscore of >/=2 at week 52. Sustained deep remission was defined as a partial Mayo score 300 mg/kg) already 3 months before the flare. Further receiver operator curve analysis suggested that a calprotectin level >300 mg/kg had a reasonable sensitivity (58.3%) and specificity (93.3%) to model flare. Two consecutive calprotectin measurements of >300 mg/kg with 1-month interval were identified as the best predictor of flare (61.5% sensitivity and 100% specificity). CONCLUSIONS: Fecal calprotectin can be used in daily practice to monitor patients with UC receiving infliximab maintenance therapy. Two consecutive measurements >300 mg/kg is more specific than a single measurement for predicting relapse

    Second-generation colon capsule endoscopy compared with colonoscopy

    No full text
    Colon capsule endoscopy (CCE) represents a noninvasive technology that allows visualization of the colon without requiring sedation and air insufflation. A second-generation colon capsule endoscopy system (PillCam Colon 2) (CCE-2) was developed to increase sensitivity for colorectal polyp detection compared with the first-generation system. OBJECTIVE: To assess the feasibility, accuracy, and safety of CCE-2 in a head-to-head comparison with colonoscopy. DESIGN AND SETTING: Prospective, multicenter trial including 8 European sites. PATIENTS: This study involved 117 patients (mean age 60 years). Data from 109 patients were analyzed. INTERVENTION: CCE-2 was prospectively compared with conventional colonoscopy as the criterion standard for the detection of colorectal polyps that are >/=6 mm or masses in a cohort of patients at average or increased risk of colorectal neoplasia. Colonoscopy was independently performed within 10 hours after capsule ingestion or on the next day. MAIN OUTCOME MEASUREMENTS: CCE-2 sensitivity and specificity for detecting patients with polyps >/=6 mm and >/=10 mm were assessed. Capsule-positive but colonoscopy-negative cases were counted as false positive. Capsule excretion rate, level of bowel preparation, and rate of adverse events also were assessed. RESULTS: Per-patient CCE-2 sensitivity for polyps >/=6 mm and >/=10 mm was 84% and 88%, with specificities of 64% and 95%, respectively. All 3 invasive carcinomas were detected by CCE-2. The capsule excretion rate was 88% within 10 hours. Overall colon cleanliness for CCE-2 was adequate in 81% of patients. LIMITATIONS: Not unblinding the CCE-2 results at colonoscopy; heterogenous patient population; nonconsecutive patients. CONCLUSION: In this European, multicenter study, CCE-2 appeared to have a high sensitivity for the detection of clinically relevant polypoid lesions, and it might be considered an adequate tool for colorectal imaging
    corecore