11,653 research outputs found

    Declaratory Judgments

    Get PDF

    A fast algorithm for control and estimation using a polynomial state-space structure

    Get PDF
    One of the major problems associated with the control of flexible structures is the estimation of system states. Since the parameters of the structures are not constant under varying loads and conditions, conventional fixed parameter state estimators can not be used to effectively estimate the states of the system. One alternative is to use a state estimator which adapts to the condition of the system. One such estimator is the Kalman filter. This filter is a time varying recursive digital filter which is based upon a model of the system being measured. This filter adapts the model according to the output of the system. Previously, the Kalman filter has only been used in an off-line capacity due to the computational time required for implementation. With recent advances in computer technology, it is becoming a viable tool for use in the on-line environment. A distributed Kalman filter implementation is described for fast estimation of the state of a flexible arm. A key issue, is the sensor structure and initial work on a distributed sensor that could be used with the Kalman filter is presented

    Excited states of neutral donor bound excitons in GaN

    Get PDF
    We investigate the excited states of a neutral donor bound exciton (D0X) in bulk GaN by means of high-resolution, polychromatic photoluminescence excitation (PLE) spectroscopy. The optically most prominent donor in our sample is silicon accompanied by only a minor contribution of oxygen—the key for an unambiguous assignment of excited states. Consequently, we can observe a multitude of Si0X-related excitation channels with linewidths down to 200 μeV. Two groups of excitation channels are identified, belonging either to rotational-vibrational or electronic excited states of the hole in the Si0X complex. Such identification is achieved by modeling the excited states based on the equations of motion for a Kratzer potential, taking into account the particularly large anisotropy of effective hole masses in GaN. Furthermore, several ground- and excited states of the exciton-polaritons and the dominant bound exciton are observed in the photoluminescence (PL) and PLE spectra, facilitating an estimate of the associated complex binding energies. Our data clearly show that great care must be taken if only PL spectra of D0X centers in GaN are analyzed. Every PL feature we observe at higher emission energies with regard to the Si0X ground state corresponds to an excited state. Hence, any unambiguous peak identification renders PLE spectra highly valuable, as important spectral features are obscured in common PL spectra. Here, GaN represents a particular case among the wide-bandgap, wurtzite semiconductors, as comparably low localization energies for common D0X centers are usually paired with large emission linewidths and the prominent optical signature of exciton-polaritons, making the sole analysis of PL spectra a challenging task.EC/H2020/749565/EU/Heat Transport and its Effects on the Performance of Nanostructured, Photonic Materials/PhotoHeatEffectDFG, 43659573, SFB 787: Halbleiter - Nanophotonik: Materialien, Modelle, Bauelement

    Computational tools for multi-linked flexible structures

    Get PDF
    A software module which designs and tests controllers and filters in Kalman Estimator form, based on a polynomial state-space model is discussed. The user-friendly program employs an interactive graphics approach to simplify the design process. A variety of input methods are provided to test the effectiveness of the estimator. Utilities are provided which address important issues in filter design such as graphical analysis, statistical analysis, and calculation time. The program also provides the user with the ability to save filter parameters, inputs, and outputs for future use

    Long-term results of cyclosporine-steroid therapy in 131 non-matched cadaveric renal transplants.

    Get PDF
    One-hundred-and-twenty-eight recipients of 131 consecutive, non-matched cadaver renal allografts were treated with cyclosporine and steroids. They have been followed for 4 to 6 yr. Cumulative patient survival at 1-yr was 92.2% and at 6yr it is 77.8%. Cumulative graft survival at 1-yr was 79.4% and at 6 yr it is 50.0%. After the high-risk 1st yr, the rate of graft loss was even and similar to that reported after the 1st yr for grafts treated with azathioprine and steroids. This indicates that cyclosporine nephrotoxicity has not had an obvious adverse effect on the survival of chronically functioning grafts. The results were better with primary grafting versus retransplantation, but were not significantly influenced by age, diabetes mellitus, or a delayed switch in patients from cyclosporine to azathioprine. We have concluded that cyclosporine-steroid therapy is safe and effective for long-term use after cadaveric renal transplantation

    On the Photometric Accuracy of RHESSI Imaging and Spectrosocopy

    Full text link
    We compare the photometric accuracy of spectra and images in flares observed with the Ramaty High Energy Solar Spectroscopic Imager (RHESSI)}spacecraft. We test the accuracy of the photometry by comparing the photon fluxes obtained in different energy ranges from the spectral-fitting software SPEX with those fluxes contained in the images reconstructed with the Clean, MEM, MEM-Vis, Pixon, and Forward-fit algorithms. We quantify also the background fluxes, the fidelity of source geometries, and spatial spectra reconstructed with the five image reconstruction algorithms. We investigate the effects of grid selection, pixel size, field-of-view, and time intervals on the quality of image reconstruction. The detailed parameters and statistics are provided in an accompanying CD-ROM and web page. We find that Forward-fit, Pixon, and Clean have a robust convergence behavior and a photometric accuracy in the order of a few percents, while MEM does not converge optimally for large degrees of freedom (for large field-of-views and/or small pixel sizes), and MEM-Vis suffers in the case of time-variable sources. This comparative study documents the current status of the RHESSI spectral and imaging software, one year after launch.Comment: 2 Figures, full version on http://www.lmsal.com/~aschwand/eprints/2003_photo/index.htm

    SPIFI: a Direct-Detection Imaging Spectrometer for Submillimeter Wavelengths

    Get PDF
    The South Pole Imaging Fabry-Perot Interferometer (SPIFI) is the first instrument of its kind -a direct-detection imaging spectrometer for astronomy in the submillimeter band. SPIFI ’s focal plane is a square array of 25 silicon bolometers cooled to 60 mK; the spectrometer consists of two cryogenic scanning Fabry-Perot interferometers in series with a 60-mK bandpass filter. The instrument operates in the short submillimeter windows (350 and 450 μm) available from the ground, with spectral resolving power selectable between 500 and 10,000. At present, SPIFI’s sensitivity is within a factor of 1.5-3 of the photon background limit, comparable with the best heterodyne spectrometers. The instrument ’s large bandwidth and mapping capability provide substantial advantages for specific astrophysical projects, including deep extragalactic observations. We present the motivation for and design of SPIFI and its operational characteristics on the telescope

    A Multidimensional Conceptualization of Environmental Velocity

    Get PDF
    Environmental velocity has emerged as an important concept but remains theoretically underdeveloped, particularly with respect to its multidimensionality. In response, we develop a framework that examines the variations in velocity across multiple dimensions of the environment (homology) and the causal linkages between those velocities (coupling). We then propose four velocity regimes based on different patterns of homology and coupling and argue that the conditions of each regime have important implications for organizations
    • …
    corecore