879 research outputs found
Surfactant protein D inhibits HIV-1 infection of target cells via interference with gp120-CD4 interaction and modulates pro-inflammatory cytokine production
© 2014 Pandit et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.Surfactant Protein SP-D, a member of the collectin family, is a pattern recognition protein, secreted by mucosal epithelial cells and has an important role in innate immunity against various pathogens. In this study, we confirm that native human SP-D and a recombinant fragment of human SP-D (rhSP-D) bind to gp120 of HIV-1 and significantly inhibit viral replication in vitro in a calcium and dose-dependent manner. We show, for the first time, that SP-D and rhSP-D act as potent inhibitors of HIV-1 entry in to target cells and block the interaction between CD4 and gp120 in a dose-dependent manner. The rhSP-D-mediated inhibition of viral replication was examined using three clinical isolates of HIV-1 and three target cells: Jurkat T cells, U937 monocytic cells and PBMCs. HIV-1 induced cytokine storm in the three target cells was significantly suppressed by rhSP-D. Phosphorylation of key kinases p38, Erk1/2 and AKT, which contribute to HIV-1 induced immune activation, was significantly reduced in vitro in the presence of rhSP-D. Notably, anti-HIV-1 activity of rhSP-D was retained in the presence of biological fluids such as cervico-vaginal lavage and seminal plasma. Our study illustrates the multi-faceted role of human SPD against HIV-1 and potential of rhSP-D for immunotherapy to inhibit viral entry and immune activation in acute HIV infection. © 2014 Pandit et al.The work (Project no. 2011-16850) was supported by Medical Innovation Fund of Indian Council of Medical Research, New Delhi, India (www.icmr.nic.in/)
Assessment of left ventricular function by three-dimensional echocardiography.
Accurate determination of LV volume, ejection fraction and segmental wall
motion abnormalities is important for clinical decision-making and
follow-up assessment. Currently, echocardiography is the most common used
method to obtain this information. Three-dimensional echocardiography has
shown to be an accurate and reproducible method for LV quantitation,
mainly by avoiding the use of geometric assumptions. In this review, we
describe various methods to acquire a 3D-dataset for LV volume and wall
motion analysis, including their advantages and limitations. We provide an
overview of studies comparing LV volume and function measurement by
various gated and real-time methods of acquisition compared to magnetic
resonance imaging. New technical improvements, such as automated
endocardial border detection and contrast enhancement, will make accurate
on-line assessment with little operator interaction possible in the near
future
Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics
BACKGROUND: This study explores the feasibility of non-invasive evaluation of left ventricular (LV) flow-volume dynamics using 3-dimensional (3D) echocardiography, and the capacity of such an approach to identify altered LV hemodynamic states caused by valvular abnormalities. METHODS: Thirty-one patients with moderate-severe aortic (AS) and mitral (MS) stenoses (21 and 10 patients, respectively) and 10 healthy volunteers underwent 3D echocardiography with full volume acquisition using Philips Sonos 7500 equipment. The digital 3D data were post- processed using TomTec software. LV flow-volume loops were subsequently constructed for each subject by plotting instantaneous LV volume data sampled throughout the cardiac cycle vs. their first derivative representing LV flow. After correction for body surface area, an average flow-volume loop was calculated for each subject group. RESULTS: Flow-volume loops were obtainable in all subjects, except 3 patients with AS. The flow-volume diagrams displayed clear differences in the form and position of the loops between normal individuals and the respective patient groups. In patients with AS, an "obstructive" pattern was observed, with lower flow values during early systole and larger end-systolic volume. On the other hand, patients with MS displayed a "restrictive" flow-volume pattern, with reduced diastolic filling and smaller end-diastolic volume. CONCLUSION: Non-invasive evaluation of LV flow-volume dynamics using 3D-echocardiographic data is technically possible and the approach has a capacity to identify certain specific types of alteration of LV flow-volume pattern caused by valvular abnormalities, thus reflecting underlying hemodynamic states specific for these abnormalities
A Right Atrial Hemangioma Mimicking Thrombus In A Patient With Atrial Arrhythmias
Cardiac hemangiomas are rare tumors, accounting for only 2.8% of all benign primary cardiac tumors and occur at any age. Clinical presentations vary depending on the tumor location (myocardial, endocardial or pericardial). In many cases, this may be an incidental finding. We report the case of a patient with paroxysmal atrial fibrillation who had a right atrial hemangioma detected with transesophageal echocardiography prior to having percutaneous pulmonary vein isolation performe
Age and gender specific normal values of left ventricular mass, volume and function for gradient echo magnetic resonance imaging: a cross sectional study
<p>Abstract</p> <p>Background</p> <p>Knowledge about age-specific normal values for left ventricular mass (LVM), end-diastolic volume (EDV), end-systolic volume (ESV), stroke volume (SV) and ejection fraction (EF) by cardiac magnetic resonance imaging (CMR) is of importance to differentiate between health and disease and to assess the severity of disease. The aims of the study were to determine age and gender specific normal reference values and to explore the normal physiological variation of these parameters from adolescence to late adulthood, in a cross sectional study.</p> <p>Methods</p> <p>Gradient echo CMR was performed at 1.5 T in 96 healthy volunteers (11–81 years, 50 male). Gender-specific analysis of parameters was undertaken in both absolute values and adjusted for body surface area (BSA).</p> <p>Results</p> <p>Age and gender specific normal ranges for LV volumes, mass and function are presented from the second through the eighth decade of life. LVM, ESV and EDV rose during adolescence and declined in adulthood. SV and EF decreased with age. Compared to adult females, adult males had higher BSA-adjusted values of EDV (p = 0.006) and ESV (p < 0.001), similar SV (p = 0.51) and lower EF (p = 0.014). No gender differences were seen in the youngest, 11–15 year, age range.</p> <p>Conclusion</p> <p>LV volumes, mass and function vary over a broad age range in healthy individuals. LV volumes and mass both rise in adolescence and decline with age. EF showed a rapid decline in adolescence compared to changes throughout adulthood. These findings demonstrate the need for age and gender specific normal ranges for clinical use.</p
The limited usefulness of real-time 3-dimensional echocardiography in obtaining normal reference ranges for right ventricular volumes
<p>Abstract</p> <p>Background</p> <p>To obtain normal reference ranges and intraobserver variability for right ventricular (RV) volume indexes (VI) and ejection fraction (EF) from apical recordings with real-time 3-dimensional echocardiography (RT3DE), and similarly for RV area indexes (AI) and area fraction (AF) with 2-dimensional echocardiography (2DE).</p> <p>Methods</p> <p>166 participants; 79 males and 87 females aged between 29–79 years and considered free from clinical and subclinical cardiovascular disease. Normal ranges are defined as 95% reference values and reproducibility as coefficients of variation (CV) for repeated measurements.</p> <p>Results</p> <p>None of the apical recordings with RT3DE and 2DE included the RV outflow tract. Upper reference values were 62 ml/m<sup>2 </sup>for RV end-diastolic (ED) VI and 24 ml/m<sup>2 </sup>for RV end-systolic (ES) VI. Lower normal reference value for RVEF was 41%. The respective reference ranges were 17 cm<sup>2</sup>/m<sup>2 </sup>for RVEDAI, 11 cm<sup>2</sup>/m<sup>2 </sup>for RVESAI and 27% for RVAF. Males had higher upper normal values for RVEDVI, RVESVI and RVEDAI, and a lower limit than females for RVEF and RVAF. Weak but significant negative correlations between age and RV dimensions were found with RT3DE, but not with 2DE. CVs for repeated measurements ranged between 10% and 14% with RT3DE and from 5% to 14% with 2DE.</p> <p>Conclusion</p> <p>Although the normal ranges for RVVIs and RVAIs presented in this study reflect RV inflow tract dimensions only, the data presented may still be regarded as a useful tool in clinical practice, especially for RVEF and RVAF.</p
Measurement of Trilinear Gauge Couplings in Collisions at 161 GeV and 172 GeV
Trilinear gauge boson couplings are measured using data taken by DELPHI at 161~GeV and 172~GeV. Values for couplings () are determined from a study of the reactions \eeWW\ and \eeWev, using differential distributions from the final state in which one decays hadronically and the other leptonically, and total cross-section data from other channels. Limits are also derived on neutral couplings from an analysis of the reaction \eegi
Primary cerebello-pontine angle melanoma: a case report
Intra-cranial melanomas are commonly metastatic from primary melanoma elsewhere in the body. The primary occurrence of a melanoma in the brain parenchyma is rare. We report a case of 38 year aged woman who presented with deviation of left eye and headache. On imaging, a space occupying lesion was found in the left Cerebello-pontine angle and a preoperative diagnosis of meningioma was made. She underwent left retro-mastoid sub-occipital craniectomy and excision of a black vascular tumor. Histopathological examination revealed a melanoma which was confirmed with Immunohistochemical assay. Search for dermal, mucous and ocular lesions were negative. She received adjuvant radiation to the post- operative tumor bed to 5400cGy in 30 fractions using Intensity Modulated Radiation Therapy technique along with concurrent Temozolomide. She tolerated the treatment well and is symptom free 12 months after treatment. Primary Melanomas are rare lesions of the Cerebello-pontine angle and its radiological features, evaluation and management have been discussed.-------------------Cite this article as: Ponni A, Jagannatha A, Gururajachar J, Harjani R, Koushik K, Subramanian N, Sowmya R, Varma R. Primary cerebello-pontine angle melanoma: a case report. Int J Cancer Ther Oncol 2014; 2(3):020315. DOI: 10.14319/ijcto.0203.1
Expressão de caracteres de tubérculos em função do tamanho de recipiente usado no cultivo de batata na geração de plântulas
Assessment of left ventricular volumes using simplified 3-D echocardiography and computed tomography – a phantom and clinical study
<p>Abstract</p> <p>Objectives</p> <p>To compare the accuracy of simplified 3-dimensional (3-D) echocardiography vs. multi-slice computed tomography (MSCT) software for the quantification of left ventricular (LV) volumes.</p> <p>Design</p> <p>Three-D echocardiography (3-planes approach) and MSCT-CardIQ software were calibrated by measuring known volumes of 10 phantoms designed to closely mimic blood-endocardium interface. Subsequently, LV volumes were measured with both the methods in 9 patients referred routinely for coronary angiography and the agreement between the measurements was evaluated.</p> <p>Results</p> <p>Simplified 3D-echocardiography provided higher degree of agreement between the measured and true phantom volumes (mean difference 0 ± 1 ml, variation range +4 to -4 ml) than MSCT software (mean difference 6 ± 5 ml; variation range +22 to -10 ml). The agreement between LV measurements in the patients was considerably poorer, with significantly larger volumes produced by MSCT (mean difference -23 ± 40 ml, variation between +93 and -138 ml).</p> <p>Conclusion</p> <p>Simplified 3-D echocardiography provides more accurate assessment of phantom volumes than MSCT-CardIQ software. The discrepancy between the results of LV measurements with the two methods is even greater and does not warrant their interchangeable diagnostic use.</p
- …
