5,016 research outputs found

    Interplanetary Coronal Mass Ejections observed by MESSENGER and Venus Express

    Get PDF
    Interplanetary coronal mass ejections (ICMEs) observed by the MESSENGER (MES) and Venus Express (VEX) spacecraft have been catalogued and analysed. The ICMEs were identified by a relatively smooth rotation of the magnetic field direction consistent with a flux rope structure, coinciding with a relatively enhanced magnetic field strength. A total of 35 ICMEs were found in the surveyed MES data (primarily from March 2007 to April 2012), and 84 ICMEs in the surveyed VEX data (from May 2006 to December 2013). The ICME flux rope configurations have been determined. Ropes with northward leading edges were about four times more common than ropes with southward leading edges, in agreement with a previously established solar cycle dependence. Ropes with low inclinations to the solar equatorial plane were about four times more common than ropes with high inclinations, possibly an observational effect. Left and right-handed ropes were observed in almost equal numbers. In addition, data from MES, VEX, STEREO-A, STEREO-B and ACE were examined for multipoint signatures of the catalogued ICMEs. For spacecraft separations below 15{\deg} in heliocentric longitude, the second spacecraft observed the ICME flux rope in 82% of cases; this percentage dropped to 49% for separations between 15 and 30{\deg}, to 18% for separations between 30 and 45{\deg}, and to 12% for separations between 45 and 60{\deg}. As spacecraft separation increased, it became increasingly likely that only the sheath and not the flux rope of the ICME was observed, in agreement with the notion that ICME flux ropes are smaller in longitudinal extent than the shocks or discontinuities that they often drive. Furthermore, this study has identified 23 ICMEs observed by pairs of spacecraft close to radial alignment. A detailed analysis of these events could lead to a better understanding of how ICMEs evolve during propagation.Comment: 28 pages, 7 figure

    Low dimensional magnetic solids and single crystal elpasolites: Need for improved crystal growing techniques

    Get PDF
    The need for extensive crystal growing experiments to develop techniques for preparing crystals suitable for magnetic anisotropy measurements and detailed X-ray and neutron diffraction studies is rationalized on the basis of the unique magnetic properties of the materials and their hydrogen bonded structures which have many features in common with metalloenzyme and metalloprotein active sites. Single crystals of the single and mixed lanthanide species are prepared by the Bridgeman technique of gradient solidification of molten samples. The effects of crystal imperfections on the optical properties of these materials are an important part of the projected research. A series of a-amido acid complexes of first row transition metals were prepared which crystallize as infinite linear chains and exhibit low dimensional magnetic ordering (one or two) at temperature below 40 K

    Crystal structure of the catalytic fragment of murine poly(ADP-ribose) polymerase-2.

    Get PDF
    Poly(ADP-ribose) polymerase-1 (PARP-1) has become an important pharmacological target in the treatment of cancer due to its cellular role as a 'DNA-strand break sensor', which leads in part to resistance to some existing chemo- and radiological treatments. Inhibitors have now been developed which prevent PARP-1 from synthesizing poly(ADP-ribose) in response to DNA-breaks and potentiate the cytotoxicity of DNA damaging agents. However, with the recent discoveries of PARP-2, which has a similar DNA-damage dependent catalytic activity, and additional members containing the 'PARP catalytic' signature, the isoform selectivity and resultant pharmacological effects of existing inhibitors are brought into question. We present here the crystal structure of the catalytic fragment of murine PARP-2, at 2.8 A resolution, and compare this to the catalytic fragment of PARP-1, with an emphasis on providing a possible framework for rational drug design in order to develop future isoform-specific inhibitors

    Ultrasound for Non-invasive Fluid Droplet Detection inside a Sealed Container

    Get PDF
    Ultrasound has long been known to be capable of measuring water level. Zero-degree ultrasound transducers may be used to send an L-wave through the fluid and receive a reflected signal from the fluid/gas interface surface. The level of the fluid is proportional to the sound wave time of flight to traverse the water path. This approach may even be used from outside the fluid containment wall by sending the wave through the tank or pipe bottom. The approach, however, does not work well if there is only a thin layer of fluid consisting of one or two millimeters or even only a few droplets. Surface waves are also known to be sensitive to the presence or absence of fluid on a surface. A surface wave may be transmitted a significant distance by a transmitting transducer and then received by a similar transducer. If the surface along the wave path is wet with even a few droplets of fluid, the surface wave may be significantly attenuated. Generating and measuring such a surface wave from the opposite side of a tank or pipe containment wall and separating the near-wall surface wave from the far-wall surface wave, however, is more challenging. An approach for producing a surface wave on the opposite side of a steel plate to sense the presence or absence of fluid is discussed. This approach is supported by 2-D finite element modeling of the measurement configuration and by empirical demonstration of the technique’s sensitivity. This technique was developed for measurement of a very small amount of fluid that may condense within a spent nuclear fuel canister after it cools for several years. Such small amounts of fluid are of concern for initiating stress corrosion cracking over the decades that these nuclear waste containment structures are expected to remain leak-free. Early detection of fluid would provide advance warning of potential cracks in time for mitigation or management of the waste inside that container. Other potential applications include any non-intrusive liquid container fluid detection, detection of fluid within inaccessible plena of aircrafts or other complex welded skin structures

    Adaptable-radius, time-orbiting magnetic ring trap for Bose-Einstein condensates

    Full text link
    We theoretically investigate an adjustable-radius magnetic storage ring for laser-cooled and Bose-condensed atoms. Additionally, we discuss a novel time-dependent variant of this and other ring traps. Time-orbiting ring traps provide a high optical access method for spin-flip loss prevention near a storage ring's circular magnetic field zero. Our scalable storage ring will allow one to probe the fundamental limits of condensate Sagnac interferometry.Comment: 5 pages, 3 figures. accepted in J Phys

    Small-scale flux ropes in ICME sheaths

    Get PDF
    Sheath regions of interplanetary coronal mass ejections (ICMEs) are formed when the upstream solar wind is deflected and compressed due to the propagation and expansion of the ICME. Small-scale flux ropes found in the solar wind can thus be swept into ICME-driven sheath regions. They may also be generated locally within the sheaths through a range of processes. This work applies wavelet analysis to obtain the normalized reduced magnetic helicity, normalized cross helicity, and normalized residual energy, and uses them to identify small-scale flux ropes and Alfven waves in 55 ICME-driven sheath regions observed by the Wind spacecraft in the near-Earth solar wind. Their occurrence is investigated separately for three different frequency ranges between 10(-2) - 10(-4) Hz. We find that small scale flux ropes are more common in ICME sheaths than in the upstream wind, implying that they are at least to some extent actively generated in the sheath and not just compressed from the upstream wind. Alfven waves occur more evenly in the upstream wind and in the sheath. This study also reveals that while the highest frequency (smallest scale) flux ropes occur relatively evenly across the sheath, the lower frequency (largest scale) flux ropes peak near the ICME leading edge. This suggests that they could have different physical origins, and that processes near the ICME leading edge are important for generating the larger scale population.Peer reviewe

    Matter effects in the D0-D0bar system

    Full text link
    We discuss the impact of matter effects in the D0-D0bar system. We show that such effects could, in principle, be measured, but that they cannot be used to probe the mass difference x_D or the lifetime difference y_D. This occurs because the mixing effects and the matter effects decouple at short times. We also comment briefly on the B systems.Comment: 6 pages, RevTe

    Transmittance Measurement of a Heliostat Facility used in the Preflight Radiometric Calibration of Earth-Observing Sensors

    Get PDF
    Ball Aerospace and Technologies Corporation in Boulder, Colorado, has developed a heliostat facility that will be used to determine the preflight radiometric calibration of Earth-observing sensors that operate in the solar-reflective regime. While automatically tracking the Sun, the heliostat directs the solar beam inside a thermal vacuum chamber, where the sensor under test resides. The main advantage to using the Sun as the illumination source for preflight radiometric calibration is because it will also be the source of illumination when the sensor is in flight. This minimizes errors in the pre- and post-launch calibration due to spectral mismatches. It also allows the instrument under test to operate at irradiance values similar to those on orbit. The Remote Sensing Group at the University of Arizona measured the transmittance of the heliostat facility using three methods, the first of which is a relative measurement made using a hyperspectral portable spectroradiometer and well-calibrated reference panel. The second method is also a relative measurement, and uses a 12-channel automated solar radiometer. The final method is an absolute measurement using a hyperspectral spectroradiometer and reference panel combination, where the spectroradiometer is calibrated on site using a solar-radiation-based calibration
    corecore