433 research outputs found

    Alaska's Economy and Housing Market

    Get PDF

    Mapping of the EQ-5D index from clinical outcome measures and demographic variables in patients with coronary heart disease.

    Get PDF
    RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are.BACKGROUND: The EuroQoL 5D (EQ-5D) is a questionnaire that provides a measure of utility for cost-effectiveness analysis. The EQ-5D has been widely used in many patient groups, including those with coronary heart disease. Studies often require patients to complete many questionnaires and the EQ-5D may not be gathered. This study aimed to assess whether demographic and clinical outcome variables, including scores from a disease specific measure, the Seattle Angina Questionnaire (SAQ), could be used to predict, or map, the EQ-5D index value where it is not available. METHODS: Patient-level data from 5 studies of cardiac interventions were used. The data were split into two groups - approximately 60% of the data were used as an estimation dataset for building models, and 40% were used as a validation dataset. Forward ordinary least squares linear regression methods and measures of prediction error were used to build a model to map to the EQ-5D index. Age, sex, a proxy measure of disease stage, Canadian Cardiovascular Society (CCS) angina severity class, treadmill exercise time (ETT) and scales of the SAQ were examined. RESULTS: The exertional capacity (ECS), disease perception (DPS) and anginal frequency scales (AFS) of the SAQ were the strongest predictors of the EQ-5D index and gave the smallest root mean square errors. A final model was chosen with age, gender, disease stage and the ECS, DPS and AFS scales of the SAQ. ETT and CCS did not improve prediction in the presence of the SAQ scales. Bland-Altman agreement between predicted and observed EQ-5D index values was reasonable for values greater than 0.4, but below this level predicted values were higher than observed. The 95% limits of agreement were wide (-0.34, 0.33). CONCLUSIONS: Mapping of the EQ-5D index in cardiac patients from demographics and commonly measured cardiac outcome variables is possible; however, prediction for values of the EQ-5D index below 0.4 was not accurate. The newly designed 5-level version of the EQ-5D with its increased ability to discriminate health states may improve prediction of EQ-5D index values

    A review of health utilities using the EQ-5D in studies of cardiovascular disease

    Get PDF
    RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are.Abstract Background The EQ-5D has been extensively used to assess patient utility in trials of new treatments within the cardiovascular field. The aims of this study were to review evidence of the validity and reliability of the EQ-5D, and to summarise utility scores based on the use of the EQ-5D in clinical trials and in studies of patients with cardiovascular disease. Methods A structured literature search was conducted using keywords related to cardiovascular disease and EQ-5D. Original research studies of patients with cardiovascular disease that reported EQ-5D results and its measurement properties were included. Results Of 147 identified papers, 66 met the selection criteria, with 10 studies reporting evidence on validity or reliability and 60 reporting EQ-5D responses (VAS or self-classification). Mean EQ-5D index-based scores ranged from 0.24 (SD 0.39) to 0.90 (SD 0.16), while VAS scores ranged from 37 (SD 21) to 89 (no SD reported). Stratification of EQ-5D index scores by disease severity revealed that scores decreased from a mean of 0.78 (SD 0.18) to 0.51 (SD 0.21) for mild to severe disease in heart failure patients and from 0.80 (SD 0.05) to 0.45 (SD 0.22) for mild to severe disease in angina patients. Conclusions The published evidence generally supports the validity and reliability of the EQ-5D as an outcome measure within the cardiovascular area. This review provides utility estimates across a range of cardiovascular subgroups and treatments that may be useful for future modelling of utilities and QALYs in economic evaluations within the cardiovascular area.Published versio

    l-Menthol mouth rinse or ice slurry ingestion during the latter stages of exercise in the heat provide a novel stimulus to enhance performance despite elevation in mean body temperature

    Get PDF
    PURPOSE: This study investigated the effects of L-menthol mouth rinse and ice slurry ingestion on time to exhaustion, when administered at the latter stages (~ 85%) of baseline exercise duration in the heat (35 °C).METHOD: Ten male participants performed four time to exhaustion (TTE) trials on a cycle ergometer at 70% Wmax. In a randomized crossover design, (1) placebo-flavored non-calorific mouth rinse, (2) L-menthol mouth rinse (0.01%), or (3) ice ingestion (1.25 g kg-1), was administered at 85% of participants' baseline TTE. Time to exhaustion, core and skin temperature, heart rate, rating of perceived effort, thermal comfort and thermal sensation were recorded.RESULTS: From the point of administration at 85% of baseline TTE, exercise time was extended by 1% (placebo, 15 s), 6% (L-menthol, 82 s) and 7% (ice, 108 s), relative to baseline performance (P = 0.036), with no difference between L-menthol and ice (P > 0.05). Core temperature, skin temperature, and heart rate increased with time but did not differ between conditions (P > 0.05). Thermal sensation did not differ significantly but demonstrated a large effect size (P = 0.080; [Formula: see text] = 0.260).CONCLUSION: These results indicate that both thermally cooling and non-thermally cooling oral stimuli have an equal and immediate behavioral, rather than physiological, influence on exhaustive exercise in the heat

    Relationship between the EQ-5D index and measures of clinical outcomes in selected studies of cardiovascular interventions.

    Get PDF
    RIGHTS : This article is licensed under the BioMed Central licence at http://www.biomedcentral.com/about/license which is similar to the 'Creative Commons Attribution Licence'. In brief you may : copy, distribute, and display the work; make derivative works; or make commercial use of the work - under the following conditions: the original author must be given credit; for any reuse or distribution, it must be made clear to others what the license terms of this work are.BACKGROUND: The EuroQoL 5D (EQ-5D) has been widely used in studies of cardiac disease, but its measurement properties in this group are not well established. The study aimed to quantify the relationship between measures commonly used in studies of cardiac disease and the EQ-5D index across different levels of disease severity. METHODS: Patient-level data from 7 studies of cardiac interventions were used, which included randomised trials and observational studies. Relationships between the EQ-5D index and commonly used cardiac measures, Canadian Cardiovascular Society (CCS) angina severity class, treadmill exercise time (ETT) and scales of the Seattle Angina Questionnaire (SAQ) were examined. Mixed effects linear regression was used to assess these relationships, with the EQ-5D index as the response. RESULTS: Study sample sizes ranged from 68 to 2419. Mean baseline EQ-5D index ranged from 0.77 in patients at diagnosis (95% CI 0.75, 0.78) to 0.43 in patients with advanced disease (95% CI 0.39, 0.48) and differed significantly across studies (p < 0.001). There was evidence of a ceiling effect in patients at diagnosis. The minimum clinically important difference of a one minute increase in ETT was associated with a 0.019 (95% CI 0.014, 0.025) increase in EQ-5D index. One class increase in CCS was associated with a 0.11 (95% CI 0.09, 0.13) decrease in EQ-5D index. A 10 unit increase in SAQ scales was associated with increases between 0.04 and 0.07 in EQ-5D index (95% CIs 0.03, 0.05 and 0.05, 0.08). Tests of heterogeneity indicated the EQ-5D-covariate relationships were consistent across levels of disease severity for ETT and the treatment satisfaction scale of the SAQ, but heterogeneous for age, gender, CCS angina class and other scales of the SAQ. CONCLUSION: The EQ-5D index varies with coronary disease severity. The relationship between the EQ-5D index and an outcome measure used in cardiac intervention studies, ETT, was consistent across disease severity levels, but the relationship between demographic variables, CCS angina class and most of the SAQ scales and the EQ-5D index was heterogeneous for patients with different levels of coronary disease. Differences in the EQ-5D index associated with clinically important differences in cardiac measures can be quantified and vary between three important examples - angina class, ETT and SAQ
    corecore