58 research outputs found

    Primary uncleansed 2D versus primary electronically cleansed 3D in limited bowel preparation CT-colonography. Is there a difference for novices and experienced readers?

    Get PDF
    The purpose of this study was to compare a primary uncleansed 2D and a primary electronically cleansed 3D reading strategy in CTC in limited prepped patients. Seventy-two patients received a low-fibre diet with oral iodine before CT-colonography. Six novices and two experienced observers reviewed both cleansed and uncleansed examinations in randomized order. Mean per-polyp sensitivity was compared between the methods by using generalized estimating equations. Mean per-patient sensitivity, and specificity were compared using the McNemar test. Results were stratified for experience (experienced observers versus novice observers). Mean per-polyp sensitivity for polyps 6 mm or larger was significantly higher for novices using cleansed 3D (65%; 95%CI 57–73%) compared with uncleansed 2D (51%; 95%CI 44–59%). For experienced observers there was no significant difference. Mean per-patient sensitivity for polyps 6 mm or larger was significantly higher for novices as well: respectively 75% (95%CI 70–80%) versus 64% (95%CI 59–70%). For experienced observers there was no statistically significant difference. Specificity for both novices and experienced observers was not significantly different. For novices primary electronically cleansed 3D is better for polyp detection than primary uncleansed 2D

    Frequency and Nature of Incidental Extra-Enteric Lesions Found on Magnetic Resonance Enterography (MR-E) in Patients with Inflammatory Bowel Diseases (IBD)

    Get PDF
    The aim of this study was to determine the occurrence of extra-enteric findings in a large cohort of patients undergoing magnetic resonance enterography (MR-E) and to classify the clinical significance of these findings.We retrospectively analyzed 1154 MR-E performed in 1006 patients referred to our radiological department between 1999-2005. The reasons for referral were suspected or proven inflammatory bowel diseases (IBD) (n = 710), further diagnostic work-up for small bowel disease because of non-specific abdominal symptoms (SBD; n = 182) or suspected small bowel malignancies (SBM; n = 114). All extra-enteric findings were reviewed by a radiologist and a gastroenterologist and were classified as having high, moderate, or low significance for further diagnostic or therapeutic procedures.The average age of all patients was 40+/-16 (Mean+/-SD) years (y) (IBD 35+/-13 y; SBD 49+/-16 y; SBM 57+/-15 y). A total of 1113 extra-enteric findings were detected in 600 of 1006 patients (59.6%). Of these findings 180 (16.2%) were judged as having a high, 212 (19.0%) a moderate and 721 (64.8%) a low significance. On a per group basis in patients with IBD 12.0% of the findings were of major clinical significance compared to 13.7% and 33.3% in patients with SBD and SBM, respectively. The most common major findings were abscesses (69.9%) in the IBD group and extraintestinal tumors, metastases or masses in the SBD and SBM groups (41.9% and 74.2%, respectively).MR-E reveals a substantial number of extra-enteric findings, supporting the role of a cross-sectional imaging method for the evaluation of the small bowel

    Does CT colonography have a role for population-based colorectal cancer screening?

    Get PDF
    Colorectal cancer (CRC) is the second most common cancer and second most common cause of cancer-related deaths in Europe. CRC screening has been proven to reduce disease-specific mortality and several European countries employ national screening programmes. These almost exclusively rely on stool tests, with endoscopy used as an adjunct in some countries. Computed tomographic colonography (CTC) is a potential screening test, with an estimated sensitivity of 88 % for advanced neoplasia ≥10 mm. Recent randomised studies have shown that CTC and colonoscopy have similar yields of advanced neoplasia per screened invitee, indicating that CTC is potentially viable as a primary screening test. However, the evidence is not fully elaborated. It is unclear whether CTC screening is cost-effective and the impact of extracolonic findings, both medical and economic, remains unknown. Furthermore, the effect of CTC screening on CRC-related mortality is unknown, as it is also unknown for colonoscopy. It is plausible that both techniques could lead to decreased mortality, as for sigmoidoscopy and gFOBT. Although radiation exposure is a drawback, this disadvantage may be over-emphasised. In conclusion, the detection characteristics and acceptability of CTC suggest it is a viable screening investigation. Implementation will depend on detection of extracolonic disease and health-economic impact

    P3HT-Based Solar Cells: Structural Properties and Photovoltaic Performance

    Full text link
    Each year we are bombarded with B.Sc. and Ph.D. applications from students that want to improve the world. They have learned that their future depends on changing the type of fuel we use and that solar energy is our future. The hope and energy of these young people will transform future energy technologies, but it will not happen quickly. Organic photovoltaic devices are easy to sketch, but the materials, processing steps, and ways of measuring the properties of the materials are very complicated. It is not trivial to make a systematic measurement that will change the way other research groups think or practice. In approaching this chapter, we thought about what a new researcher would need to know about organic photovoltaic devices and materials in order to have a good start in the subject. Then, we simplified that to focus on what a new researcher would need to know about poly-3-hexylthiophene:phenyl-C61-butyric acid methyl ester blends (P3HT: PCBM) to make research progress with these materials. This chapter is by no means authoritative or a compendium of all things on P3HT:PCBM. We have selected to explain how the sample fabrication techniques lead to control of morphology and structural features and how these morphological features have specific optical and electronic consequences for organic photovoltaic device applications

    Acute paraplegia after myelography : decompensation of a herniatad thoracic disc

    No full text
    A 71-year-old patient presented with low back pain and slowly progressive weakness of both legs. Within a few hours after lumbar myelography, paraplegia below level L2 evolved. MR-imaging revealed a discogenic stenosis at level Th10/11. Immediate decompression by costo-transversectomy led to reversal of the neurological deficits

    Dynamic magnetic resonance angiography of the arteries of the hand : a comparison between an extracellular and an intravascular contrast agent

    No full text
    The purpose of this study was to compare the image quality of the intravascular contrast agent gadofosveset with the extracellular contrast agent gadoterate meglumine in time-resolved three-dimensional magnetic resonance (MR) angiography of the human arteries of the hand. The value of cuff compression technique for suppression of venous enhancement for both contrast agents was also investigated. Three-dimensional MR angiograms of both hands of 11 healthy volunteers were acquired for each contrast agent at 1.5-T, while subsystolic cuff compression was applied at one side. Quantitative and qualitative evaluation were performed and analyzed with Student's t-test. Visualization of vessels was superior in the images acquired with gadofosveset, especially in the late phases. Quantitative and qualitative evaluation showed significantly higher values for gadofosveset. The cuff compression at the lower arm proved to be an effective method to enhance arterial vessels. In conclusion the blood pool agent gadofosveset is superior for the dynamic imaging of the vessels of the hand when compared with the extracellular contrast agent gadoterate meglumine. To fully utilize the advantages of intravascular contrast agents, venous overlay has to be delayed or reduced, which can be achieved effectively by subsystolic lower arm cuff compression

    Performance of multidetector computed tomography colonography compared with conventional colonoscopy

    No full text
    BACKGROUND AND AIMS: This was a prospective blinded study to compare computed tomography (CT) colonography, performed with multidetector arrays CT scan (MDCT), with conventional colonoscopy for the detection of colorectal neoplasia. METHODS: Fifty patients were examined by MDCT after standard bowel preparation and rectal air insufflation in the supine and prone positions. Data sets were examined by one radiologist and one gastroenterologist blinded to the patient's history and colonoscopy results. Patients subsequently underwent colonoscopy on the same day, which served as the gold standard. RESULTS: Nine of 11 lesions >10 mm (82%), 5/15 lesions of 6-9 mm (33%), and 1/42 polyps <5 mm (3%) were detected by MDCT colonography. One false positive result for a structure larger than 10 mm was described. Nineteen of 21 patients who had no lesions during conventional colonoscopy were considered free of lesions by MDCT colonography, yielding a per patient specificity of 90%. CONCLUSION: MDCT colonography provides good data quality and has good sensitivity and specificity for the detection of colonic lesions of 10 mm or more
    corecore