34 research outputs found

    Outcome of very elderly (octogenarians) patients with coronary artery disease, all diagnosed by coronary angiography

    Get PDF
    Background: Women with ischemic heart disease (IHD) typically present less severe coronary artery atherosclerosis. Despite that, as compared with men, women maintain a worse outcome. This female susceptibility seems to be mainly related to older age of clinical presentation and heavier risk factors burden. Purpose: To investigate whether sex differences exist in the real-world management and clinical outcome of elderly patients with suspected IHD. Methods: Retrospective analysis of IHD elderly (≥ 80 years) patients undergoing coronary angiography for acute coronary syndrome (ACS) or stable angina (SA). Management strategy, including invasive revascularization or a conservative medical approach, and outcome were evaluated. Results: A total of 1420 (41% women; mean age: 83.1 ± 2.8) IHD patients referring for ACS (43%) and SA (57%) were analyzed. Men more likely accessed for SA (59.6% vs 52.5%, p<0.001) whereas ACS was the most frequent reason for angiography in women (28.8% vs 21.5%, p<0.001). No significant sex differences in the burden of obstructive epicardial disease were observed in both ACS and SA patients. No sex disparities in antiplatelet therapy, specifically clopidogrel, were detected. Compared with SA men patients, female ones received more likely a conservative therapy (p=0.049). After a median (IQR) follow-up time of 39.0 (16-71) months, a total of 514 (36%) patients died. No sex differences in cardiac death (p=0.139) was observed. Nevertheless, the Kaplan Meier curves showed a trend in lower all-cause mortality in female group(p=0.093). Conclusions: In the very elderly population, an invasive strategy is superior to a conservative one in terms of survival rate. However, a dilution of the efficacy occurs with increasing age and comorbidities, and for male patients the benefit of the invasive strategy is not clear. Prospective studies are warranted to evaluate the net benefit of an invasive or a conservative approach in older population

    Three-dimensional echocardiography and 2D-3D speckle tracking imaging in chronic pulmonary hypertension. diagnostic accuracy in detecting hemodynamic signs of RV failure

    Get PDF
    Background and objective. Our aim was to compare three-dimensional (3D) and 2D and 3D speckle tracking (2D-STE, 3D-STE) echocardiographic parameters with conventional right ventricular (RV) indexes in patients with chronic pulmonary hypertension (PH), and investigate whether these techniques could result in better correlation with hemodynamic variables indicative of heart failure. Methods. Seventy-three adult patients (mean age, 53±13 years; 44% male) with chronic PH of different etiologies were studied by echocardiography and cardiac catheterization (25 precapillary PH from pulmonary arterial hypertension, 23 obstructive pulmonary heart disease, and 23 postcapillary PH from mitral regurgitation). Thirty healthy subjects (mean age, 54±15 years; 43% male) served as controls. Standard 2D measurements (RV-FAC -fractional area change-, TAPSE -tricuspid annular plane systolic excursion-) and mitral and tricuspid tissue Doppler annular velocities were obtained. RV 3D volumes, and global and regional ejection fraction (3D-RVEF) were determined. RV strains were calculated by 2D-STE and 3D-STE. Results. RV 3D global-free-wall longitudinal strain (3DGFW-RVLS), 2D global-free-wall longitudinal strain (GFW-RVLS), apical-free-wall longitudinal strain (AFW-RVLS), basal-free-wall longitudinal strain (BFW-RVLS), and 3D-RVEF were lower in patients with pre-capillary PH (p<0.0001) and post-capillary PH (p<0.01) compared to controls. 3DGFW-RVLS (HR 4.6, 95% CI 2.79-8.38, p=0.004) and 3D-RVEF (HR 5.3, 95% CI 2.85-9.89, p=0.002) were independent predictors of mortality. ROC curves showed that the thresholds offering an adequate compromise between sensitivity and specificity for detecting hemodynamic signs of RV failure were 39% for 3D-RVEF (AUC 0.89), -17% for 3DGFW-RVLS (AUC 0.88), -18% for GFW-RVLS (AUC 0.88), -16% for AFW-RVLS (AUC 0.85), 16mm for TAPSE (AUC 0.67), and 38% for RV-FAC (AUC 0.62). Conclusions. In chronic PH, 3D, 2D-STE and 3D-STE parameters indicate global and regional RV dysfunction that is associated with RV failure hemodynamics better than conventional echo indices

    Dataset on the use of 3D speckle tracking echocardiography in light-chain amyloidosis

    Get PDF
    The dataset presented in this article is related to the research article entitled “Biventricular assessment of light-chain amyloidosis using 3D speckle tracking echocardiography: Differentiation from other forms of myocardial hypertrophy” (Vitarelli et al.,2018) [1], which examined the potential utility of left ventricular (LV) and right ventricular (RV) deformation and rotational parameters derived from three-dimensional speckle-tracking echocardiography (3DSTE) to diagnose cardiac amyloidosis(CA) and differentiate this disease from other forms of myocardial hypertrophy. The combined assessment of LV basal longitudinal strain, LV basal rotation and RV basal longitudinal strain had a high discriminative power for detecting CA. The data of this study provides more understanding on the value of LV 3DSTE deformation parameters as well as RV parameters in this particular cardiomyopathy

    Intravenous versus intracoronary bolus of glycoprotein IIb/IIIa inhibitor administration during primary percutaneous coronary intervention on long-term left ventricular systolic and diastolic function

    Get PDF
    Background: In primary percutaneous coronary intervention (PCI), glycoprotein (GP) IIb/IIIa inhibitors are often given in order to attain and maintain better myocardial perfusion. Wetested the hypothesis that intracoronary (IC) bolus of GP IIb/IIIa inhibitors might producea greater improvement in left ventricular (LV) systolic and diastolic function than an intravenous(IV) bolus.Methods and results: Seventy seven patients undergoing primary PCI for their firstST elevation myocardial infarction (STEMI) were randomly assigned to either an IC or IVbolus of GP IIb/IIIa inhibitor, followed by IV infusion. Compared with the echocardiographic findings within 3 days after PCI, LV ejection fraction was higher at 1 year, with no significant differences between the IV and IC groups (IV: 44% vs. 49%, p = 0.001; IC: 43% vs. 48%,p &lt; 0.001). LV diastolic function (E/E’) did not significantly change at 1 year by either approach.Conclusions: LV systolic function improved by a similar magnitude following primary PCI, with either IC or IV bolus administration of GP IIb/IIIa inhibitor therapy. However, no significant changes were observed in LV diastolic function

    intravenous versus intracoronary bolus of glycoprotein iib iiia inhibitor administration during primary percutaneous coronary intervention on long term left ventricular systolic and diastolic function

    Get PDF
    Background: In primary percutaneous coronary intervention (PCI), glycoprotein (GP) IIb/IIIa inhibitors are often given in order to attain and maintain better myocardial perfusion. Wetested the hypothesis that intracoronary (IC) bolus of GP IIb/IIIa inhibitors might producea greater improvement in left ventricular (LV) systolic and diastolic function than an intravenous(IV) bolus. Methods and results: Seventy seven patients undergoing primary PCI for their firstST elevation myocardial infarction (STEMI) were randomly assigned to either an IC or IVbolus of GP IIb/IIIa inhibitor, followed by IV infusion. Compared with the echocardiographic findings within 3 days after PCI, LV ejection fraction was higher at 1 year, with no significant differences between the IV and IC groups (IV: 44% vs. 49%, p = 0.001; IC: 43% vs. 48%,p < 0.001). LV diastolic function (E/E') did not significantly change at 1 year by either approach. Conclusions: LV systolic function improved by a similar magnitude following primary PCI, with either IC or IV bolus administration of GP IIb/IIIa inhibitor therapy. However, no significant changes were observed in LV diastolic function

    Case Report Bidirectional Tachycardia after an Acute Intravenous Administration of Digitalis for a Suicidal Gesture

    No full text
    Acute digoxin intoxication is a life-threating condition associated with severe cardiotoxicity. Female gender, age, low lean body mass, hypertension, and renal insufficiency may worsen the prognosis. Arrhythmias caused by digitalis glycosides are characterized by an increased automaticity coupled with concomitant conduction delay. Bidirectional tachycardia is pathognomonic of digoxin intoxication, but it is rarely observed. An 83-year-old woman was admitted to the Emergency Department after self-administration of 5 mg of digoxin i.v. for suicidal purpose. Her digoxin serum concentration was 17.4 ng/mL. The patient developed a bidirectional tachycardia and the Poison Control Center of the hospital provided digoxin immune fab. Bidirectional tachycardia quickly reversed and the patient remained stable throughout the hospital stay. This case shows that a multiple disciplinary approach, involving cardiologists and toxicologists, is essential for the management of digoxin intoxication. The optimal treatment of this rare event depends on the clinical conditions and on the serum drug concentration of the patient. Digoxin immune fab represents a safe, effective, and specific method for rapidly reversing digitalis cardiotoxicity and should be started as soon as the diagnosis is defined
    corecore