1,234 research outputs found
Apogee motor rocketry reliability improvements
Since 1963, solid propellant apogee motors have been placing satellites into geosynchronous orbits. Major technological breakthroughs are not required to satisfy future mission requirements; however, there is a need to improve reliability to enhance cost effectiveness. Several management test options are discussed. A summary of results and conclusions derived from review of missions, where failure of a solid motor was inferred, and correlation of system factors with failures are reported. Highlights of a solid motor diagnostic instrumentation study are presented. Finally, recommendations are provided for areas of future apogee motor upgrade, which will increase project cost effectiveness by reducing the potential for future flight failures
Apparatus and method for control of a solid fueled rocket vehicle Patent
Solid propellant rocket vehicle thrust control method and apparatu
Solid rocket technology advancements for space tug and IUS applications
In order for the shuttle tug or interim upper stage (IUS) to capture all the missions in the current mission model for the tug and the IUS, an auxiliary or kick stage, using a solid propellant rocket motor, is required. Two solid propellant rocket motor technology concepts are described. One concept, called the 'advanced propulsion module' motor, is an 1800-kg, high-mass-fraction motor, which is single-burn and contains Class 2 propellent. The other concept, called the high energy upper stage restartable solid, is a two-burn (stop-restartable on command) motor which at present contains 1400 kg of Class 7 propellant. The details and status of the motor design and component and motor test results to date are presented, along with the schedule for future work
Left main bronchus compression due to main pulmonary artery dilatation in pulmonary hypertension: two case reports
Abstract. Pulmonary arterial dilatation associated with pulmonary hypertension may result in significant compression of local structures. Left main coronary artery and left recurrent laryngeal nerve compression have been described. Tracheobronchial compression from pulmonary arterial dilatation is rare in adults, and there are no reports in the literature of its occurrence in idiopathic pulmonary arterial hypertension. Compression in infants with congenital heart disease has been well described. We report 2 cases of tracheobronchial compression: first, an adult patient with idiopathic pulmonary arterial hypertension who presents with symptomatic left main bronchus compression, and second, an adult patient with Eisenmenger ventricular septal defect and right-sided aortic arch, with progressive intermedius and right middle lobe bronchi compression in association with enlarged pulmonary arteries
Robotic 3D printing with earth: A case study for optimisation of 3D printing building blocks
The interest in 3D printed earthen buildings in developed countries has increased due to the demand for healthy, comfortable and sustainable buildings constructed with low carbon materials and laboursaving methods. However, the amount of research about this field is still limited. Our research aims to contribute to this field by optimising the robotic 3D printing process by investigating issues such as buckling while printing, adequate soil mix recipe for printing, print and extrusion speed calibration. This paper illustrates the process and the results of the temporary research project and the Robotic Cob Printing Workshop with MSc Computational Methods in Architecture (CMA) students at the Welsh School of Architecture, Cardiff University, in March 2022. The project aims to achieve structural stability with less material by using the geometry and the infill of the building block while exploring the role of computational design, robotic extrusion and material understanding in robotic 3D printing with earth as a low-carbon novel building method
Response to pulmonary arterial hypertension drug therapies in patients with pulmonary arterial hypertension and cardiovascular risk factors.
The age at diagnosis of pulmonary arterial hypertension (PAH) and the prevalence of cardiovascular (CV) risk factors are increasing. We sought to determine whether the response to drug therapy was influenced by CV risk factors in PAH patients. We studied consecutive incident PAH patients (n = 146) between January 1, 2008, and July 15, 2011. Patients were divided into two groups: the PAH-No CV group included patients with no CV risk factors (obesity, systemic hypertension, type 2 diabetes mellitus, permanent atrial fibrillation, mitral and/or aortic valve disease, and coronary artery disease), and the PAH-CV group included patients with at least one. The response to PAH treatment was analyzed in all the patients who received PAH drug therapy. The PAH-No CV group included 43 patients, and the PAH-CV group included 69 patients. Patients in the PAH-No CV group were younger than those in the PAH-CV group (P < 0.0001). In the PAH-No CV group, 16 patients (37%) improved on treatment and 27 (63%) did not improve, compared with 11 (16%) and 58 (84%) in the PAH-CV group, respectively (P = 0.027 after adjustment for age). There was no difference in survival at 30 months (P = 0.218). In conclusion, in addition to older age, CV risk factors may predict a reduced response to PAH drug therapy in patients with PAH
Photon Counting Using Edge-Detection Algorithm
New applications such as high-datarate, photon-starved, free-space optical communications require photon counting at flux rates into gigaphoton-per-second regimes coupled with subnanosecond timing accuracy. Current single-photon detectors that are capable of handling such operating conditions are designed in an array format and produce output pulses that span multiple sample times. In order to discern one pulse from another and not to overcount the number of incoming photons, a detection algorithm must be applied to the sampled detector output pulses. As flux rates increase, the ability to implement such a detection algorithm becomes difficult within a digital processor that may reside within a field-programmable gate array (FPGA). Systems have been developed and implemented to both characterize gigahertz bandwidth single-photon detectors, as well as process photon count signals at rates into gigaphotons per second in order to implement communications links at SCPPM (serial concatenated pulse position modulation) encoded data rates exceeding 100 megabits per second with efficiencies greater than two bits per detected photon. A hardware edge-detection algorithm and corresponding signal combining and deserialization hardware were developed to meet these requirements at sample rates up to 10 GHz. The photon discriminator deserializer hardware board accepts four inputs, which allows for the ability to take inputs from a quadphoton counting detector, to support requirements for optical tracking with a reduced number of hardware components. The four inputs are hardware leading-edge detected independently. After leading-edge detection, the resultant samples are ORed together prior to deserialization. The deserialization is performed to reduce the rate at which data is passed to a digital signal processor, perhaps residing within an FPGA. The hardware implements four separate analog inputs that are connected through RF connectors. Each analog input is fed to a high-speed 1-bit comparator, which digitizes the input referenced to an adjustable threshold value. This results in four independent serial sample streams of binary 1s and 0s, which are ORed together at rates up to 10 GHz. This single serial stream is then deserialized by a factor of 16 to create 16 signal lines at a rate of 622.5 MHz or lower for input to a high-speed digital processor assembly. The new design and corresponding hardware can be employed with a quad-photon counting detector capable of handling photon rates on the order of multi-gigaphotons per second, whereas prior art was only capable of handling a single input at 1/4 the flux rate. Additionally, the hardware edge-detection algorithm has provided the ability to process 3-10 higher photon flux rates than previously possible by removing the limitation that photoncounting detector output pulses on multiple channels being ORed not overlap. Now, only the leading edges of the pulses are required to not overlap. This new photon counting digitizer hardware architecture supports a universal front end for an optical communications receiver operating at data rates from kilobits to over one gigabit per second to meet increased mission data volume requirements
Optimum structure for a uniform load over multiple spans
This paper presents a new half-plane Michell structure that transmits a uniformly distributed load of infinite
horizontal extent to a series of equally-spaced pinned supports. Full kinematic description of the structure is obtained for the case when the maximum allowable tensile stress is greater than or equal to the allowable compressive stress. Although formal proof of optimality of the solution presented is not yet available, the proposed analytical solution is supported by substantial numerical evidence, involving the solution of problems with in excess of 10 billion potential members. Furthermore, numerical solutions for various combinations of unequal allowable stresses suggest the existence of a family of related, simple, and practically relevant
structures, which range in form from a Hemp-type arch with vertical hangers to a structure which strongly resembles a cable-stayed bridge
Sample-Clock Phase-Control Feedback
To demodulate a communication signal, a receiver must recover and synchronize to the symbol timing of a received waveform. In a system that utilizes digital sampling, the fidelity of synchronization is limited by the time between the symbol boundary and closest sample time location. To reduce this error, one typically uses a sample clock in excess of the symbol rate in order to provide multiple samples per symbol, thereby lowering the error limit to a fraction of a symbol time. For systems with a large modulation bandwidth, the required sample clock rate is prohibitive due to current technological barriers and processing complexity. With precise control of the phase of the sample clock, one can sample the received signal at times arbitrarily close to the symbol boundary, thus obviating the need, from a synchronization perspective, for multiple samples per symbol. Sample-clock phase-control feedback was developed for use in the demodulation of an optical communication signal, where multi-GHz modulation bandwidths would require prohibitively large sample clock frequencies for rates in excess of the symbol rate. A custom mixedsignal (RF/digital) offset phase-locked loop circuit was developed to control the phase of the 6.4-GHz clock that samples the photon-counting detector output. The offset phase-locked loop is driven by a feedback mechanism that continuously corrects for variation in the symbol time due to motion between the transmitter and receiver as well as oscillator instability. This innovation will allow significant improvements in receiver throughput; for example, the throughput of a pulse-position modulation (PPM) with 16 slots can increase from 188 Mb/s to 1.5 Gb/s
- …