67 research outputs found

    Sequential Tasks Shifting for Participation in Demand Response Programs

    Get PDF
    In this paper, the proposed methodology minimizes the electricity cost of a laundry room by means of load shifting. The laundry room is equipped with washing machines, dryers, and irons. Additionally, the optimization model handles demand response signals, respecting user preferences while providing the required demand reduction. The sequence of devices operation is also modeled, ensuring correct operation cycles of different types of devices which are not allowed to overlap or have sequence rules. The implemented demand response program specifies a power consumption limit in each period and offers discounts for energy prices as incentives. In addition, users can define the required number of operations for each device in specific periods, and the preferences regarding the operation of consecutive days. In the case study, results have been obtained regarding six scenarios that have been defined to survey about effects of different energy tariffs, power limitations, and incentives, in a laundry room equipped with three washing machines, two dryers, and one iron. A sensitivity analysis of the power consumption limit is presented. The results show that the proposed methodology is able to accommodate the implemented scenario, respecting user preferences and demand response program, minimizing energy costs. The final electricity price has been calculated for all scenarios to discuss the more effective schedule in each scenario.This work has received funding from Portugal 2020 under SPEAR project (NORTE-01-0247-FEDER-040224), in the scope of ITEA 3 SPEAR Project 16001 and from FEDER Funds through COMPETE program and from National Funds through (FCT) under the project UIDB/00760/2020, and CEECIND/02887/2017.info:eu-repo/semantics/publishedVersio

    Comparison of venous plasma glycemia and capillary glycemia for the screening of type 2 diabetes mellitus in the Japanese-Brazilian community of Mombuca (Guatapará-SP)

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To identify the most appropriate cut-off points of fasting glycemia for the screening of diabetes mellitus type 2 (DM2) with the comparison of the properties of capillary glycemia (CG) and venous blood plasma glycemia (PG) in a population of Japanese origin from the community of Mombuca, Guatapará - SP, Brazil.</p> <p>Methods</p> <p>This was a population-based descriptive cross-sectional study conducted on a sample of 131 individuals of both genders aged 20 years or more (66.8% of the target population). CG was measured with a glucometer in a blood sample obtained from the fingertip and PG was determined by an enzymatic method (hexokinase) in venous blood plasma, after a 10-14 hour fast in both cases. Data were analyzed by the receiver operating characteristic (ROC) curve in order to identify the best cut-off point for fasting glycemia (CG and PG) for the diagnosis of DM, using the 2-hour plasma glycemia > 200 mg/dl as gold - standard.</p> <p>Results</p> <p>The ROC curve revealed that the best cut-off point for the screening of DM was 110 mg/dl for CG and 105 mg/dl for PG, values that would optimize the relation between individuals with positive and false-positive results. The area under the ROC curve was 0.814 for CG (p < 0.01) and 0.836 for PG (p < 0.01).</p> <p>Conclusions</p> <p>The cut-off points of 105 mg/dl(5.8 mmol/l) for PG and of 110 mg/dl(6.1 mmol/l) for CG appear to be the most appropriate for the screening of DM2 in the population under study, with emphasis on the fact that the value recommended for CG is 5 mg/dl higher than that for PG, in contrast to WHO recommendations.</p
    • …
    corecore