407 research outputs found

    In conversation with…Thomas Frederic Hornbein

    Get PDF

    Cannulation of the subclavian vein using real-time ultrasound guidance

    Get PDF
    Cannulation of the subclavian vein has many advantages when compared to other anatomical sites for central venous access. Difficulty in its ultrasonic visualisation, and the perceived consequent ‘higher’ complication rate, mean that this approach has fallen out of favour. This barrier, however, may now have disappeared. In this article, we discuss the indications, contraindications and complications associated with subclavian vein cannulation, and present an ultrasound-guided approach to infraclavicular subclavian cannulation

    High altitude-related hypertensive crisis and acute kidney injury in an asymptomatic healthy individual

    Get PDF
    BACKGROUND: High-altitude exposure causes a mild to moderate rise in systolic and diastolic blood pressure. This case report describes the first documented case of a hypertensive crisis at altitude, as well as the first report of the occurrence of acute kidney injury in the context of altitude-related hypertension. CASE PRESENTATION: A healthy, previously normotensive 30-year old, embarked on a trek to Everest Base Camp (5300 m). During his 11-day ascent the subject developed increasingly worsening hypertension. In the absence of symptoms, the individual initially elected to remain at altitude as had previously been the plan. However, an increase in the severity of his hypertension to a peak of 223/119 mmHg resulted in a decision to descend. On descent he was found to have an acute kidney injury that subsequently resolved spontaneously. His blood pressure reverted to normal at sea level and subsequent investigations including a transthoracic echocardiogram, cardiac magnetic resonance imaging, renal ultrasound, and urinary catecholamines were normal. CONCLUSION: This report challenges the view that transient rises in blood pressure at altitude are without immediate risk. We review the evidence that altitude induces hypertension and discuss the implications for the management of hypertension at altitude

    A comparison of the quality of image acquisition between two different sidestream dark field video-microscopes

    Get PDF
    Sidestream dark field (SDF) imaging enables direct visualisation of the microvasculature from which quantification of key variables is possible. The new MicroScan USB3 (MS-U) video-microscope is a hand-held SDF device that has undergone significant technical upgrades from its predecessor, the MicroScan Analogue (MS-A). The MS-U claims superior quality of sublingual microcirculatory image acquisition over the MS-A, however, this has yet to be robustly confirmed. In this manuscript, we therefore compare the quality of image acquisition between these two devices. The microcirculation of healthy volunteers was visualised to generate thirty video images for each device. Two independent raters, blinded to the device type, graded the quality of the images according to the six different traits in the Microcirculation Image Quality Score (MIQS) system. Chi-squared tests and Kappa statistics were used to compare not only the distribution of scores between the devices, but also agreement between raters. MS-U showed superior image quality over MS-A in three of out six MIQS traits; MS-U had significantly more optimal images by illumination (MS-U 95% optimal images, MS-A 70% optimal images (p-value 0.003)), by focus (MS-U 70% optimal images, MS-A 35% optimal images (p-value 0.002)) and by pressure (MS-U 72.5% optimal images, MS-A 47.5% optimal images (p-value 0.02)). For each trait, there was at least 85% agreement between the raters, and all the scores for each trait were independent of the rater (all p-values > 0.05). These results show that the new MS-U provides a superior quality of sublingual microcirculatory image acquisition when compared to old MS-

    Getting the most from venous occlusion plethysmography: proposed methods for the analysis of data with a rest/exercise protocol

    Get PDF
    In this methodological manuscript, we suggest a more detailed approach to processing venous occlusion plethysmography data, one which could provide additional physiological information. Six parameters are described, all of which are easily derived from a simple and reproducible experimental rest/exercise venous occlusion plethysmography protoco

    Cardiovascular assessment for non-cardiac surgery: European guidelines

    Get PDF
    In 2014, a joint task force involving the European Society of Cardiology and European Society of Anaesthesiology assembled ‘Guidelines on non-cardiac surgery: cardiovascular assessment and management’. The guidelines, subsequently published in the European Heart Journal, are intended for physicians and collaborators involved in the perioperative care of patients undergoing non-cardiac surgery, in whom heart disease is a potential source of complications. While the guidelines are an extremely relevant and useful aid for most, if not all, medics within the hospital environment, the sheer size of the document (49 pages) renders it a feat to read and digest. Given the importance of the document for optimizing patient care, this article condenses the guidelines down to help highlight the important details

    Design and conduct of Xtreme Everest 2: an observational cohort study of Sherpa and lowlander responses to graduated hypobaric hypoxia

    Get PDF
    Objective: oxygen availability falls with ascent to altitude and also as a consequence of critical illness. Because cellular sequelae and adaptive processes may be shared in both circumstances, high altitude exposure (‘physiological hypoxia’) assists in the exploration of the response to pathological hypoxia. We therefore studied the response of healthy participants to progressive hypobaric hypoxia at altitude. The primary objective of the study was to identify differences between high altitude inhabitants (Sherpas) and lowland comparators.Methods: we performed an observational cohort study of human responses to progressive hypobaric hypoxia (during ascent) and subsequent normoxia (following descent) comparing Sherpas with lowlanders. Studies were conducted in London (35m), Kathmandu (1300m), Namche Bazaar (3500m) and Everest Base Camp (5300m). Of 180 healthy volunteers departing from Kathmandu, 64 were Sherpas and 116 were lowlanders. Physiological, biochemical, genetic and epigenetic data were collected. Core studies focused on nitric oxide metabolism, microcirculatory blood flow and exercise performance. Additional studies performed in nested subgroups examined mitochondrial and metabolic function, and ventilatory and cardiac variables. Of the 180 healthy participants who left Kathmandu, 178 (99%) completed the planned trek. Overall, more than 90% of planned testing was completed. Forty-four study protocols were successfully completed at altitudes up to and including 5300m. A subgroup of identical twins (all lowlanders) was also studied in detail.Conclusion: this programme of study (Xtreme Everest 2) will provide a rich dataset relating to human adaptation to hypoxia, and the responses seen on re-exposure to normoxia. It is the largest comprehensive high altitude study of Sherpas yet performed. Translational data generated from this study will be of relevance to diseases in which oxygenation is a major facto

    A comparison of the quality of image acquisition between the incident dark field and sidestream dark field video-microscopes

    Get PDF
    BACKGROUND: The 'Cytocam' is a third generation video-microscope, which enables real time visualisation of the in vivo microcirculation. Based upon the principle of incident dark field (IDF) illumination, this hand held computer-controlled device was designed to address the technical limitations of its predecessors, orthogonal polarization spectroscopy and sidestream dark field (SDF) imaging. In this manuscript, we aimed to compare the quality of sublingual microcirculatory image acquisition between the IDF and SDF devices. METHODS: Using the microcirculatory image quality scoring (MIQS) system, (six categories scored as either 0 = optimal, 1 = acceptable, or 10 = unacceptable), two independent raters compared 30 films acquired using the Cytocam IDF video-microscope, to an equal number obtained with an SDF device. Blinded to the origin of the films, the raters were therefore able to score between 0 and 60 for each film analysed. The scores' distributions between the two techniques were compared. RESULTS: The median MIQS (95 % CI) given to the SDF camera was 7 (1.5-12), as compared to 1 (0.5-1.0) for the IDF device (p < 0.0001). Of the six categories assessed by the MIQS, nearly one fifth of the SDF videos were scored as unacceptable for pressure (20 %), content (20 %), and stability (17 %), with focus scoring deficiently 13 % of the time. High agreement between the two raters scoring values was evident, with an intra-class correlation coefficient (ICC) of 0.96 (95 % CI: 0.94, 0.98). CONCLUSIONS: These results demonstrate that the quality of sublingual microcirculatory image acquisition is superior in the Cytocam IDF video-microscope, as compared to the SDF video-microscope
    • …
    corecore