286 research outputs found
Distribution of mass transfer over a 0.5-m-tall hydrogen-evolving electrode
In general, technical vertical electrolysers for the production of chlorine, hydrogen and oxygen are high and have a short cathode-anode distance. Up to the present, few results on mass transfer to gas-evolving electrodes in these industrial cells have been published. The mass transfe]" experiments were carried out in a divided cell for a vertical hydrogen-evolving platinum electrode in a solution containing 1 M KOH, 0.1 M KCN and 0.008 M AgCN, where the Ag(CN)f complex ion was used as the indicator ion. The platinum electrode was divided into 20 segments, each with a height of 24 mm and a width of 20 ram. Subsequent segments were separated by a 1-mm-thick Perspex layer. The height of the platinum electrode was 0.50m. It has been found that the Ag/Ag(CN)~-redox couple in an alkaline cyanide solution is very useful in determining mass transfer to a hydrogen-evolving electrode. When no hydrogen bubbles are formed at the working electrode, the mass transfer coefficient decreases at a decreasing rate as the distance from the leading edge of the working electrode increases. For a hydrogen-evolving electrode, however, it has been found that the mass transfer coefficient to the topmost 0.40 m of the working electrode is practically constant. For the entrance part of the working electrode, about 0.10m in length, the dependence of the mass transfer coefficient on the distance to the leading edge of the electrode is complicated. The mass transfer coefficient and the mass transfer enhancement factor for the topmost 0.40 m of the hydrogen-evolving working electrode are given by complex correlations as a function of the current density required for hydrogen evolution and of the flow rate of solution. The effect of viscosity increase of the solution, caused by addition of a polymer, has been investigated. It has been found that the mass transfer coefficient decreases with increasing viscosity of solution in both cases, namely with and without gas bubble evolution, and that the mass transfer enhancement factor is independent of the viscosity of solution
Effectiveness of 3D-printed orthoses for traumatic and chronic hand conditions: A scoping review
Background In the field of orthotics, the use of three-dimensional (3D) technology as an alternative to the conventional production process of orthoses is growing. Purpose This scoping review aimed to systematically map and summarize studies assessing the effectiveness of 3D-printed orthoses for traumatic and chronic hand conditions, and to identify knowledge gaps. Methods The Cochrane Library, PubMed, EMBASE, CINAHL, Web of Science, IEEE, and PEDro were searched for studies of any type of 3D-printed orthoses for traumatic and chronic hand conditions. Any outcome related to the effectiveness of 3D-printed orthoses was considered. Two reviewers selected eligible studies, charted data on study characteristics by impairment type, and critically appraised the studies, except for case reports/series. Results Seventeen studies were included: Four randomized controlled trials, four uncontrolled trials, four case series and five case reports. Only three studies had a sample size >20. Impairments described were forearm fractures (n = 5), spasticity (n = 5), muscle weakness (n = 4), joint contractures (n = 2) and pain (n = 1). Four poor to fair quality studies on forearm fractures supported the effectiveness of 3D-printed orthoses on hand function, functionality, and satisfaction. One good quality study on spasticity demonstrated the effectiveness of 3D-printed orthoses on hand function. One poor quality pain study reported limited positive effects on satisfaction. Studies on muscle weakness and joint contractures showed no benefits. Conclusion Current literature addressing the effectiveness of 3D-printed orthoses for traumatic and chronic hand conditions consists primarily of small and poor methodological quality studies. There is a need for well-designed controlled trials including patient-related outcomes, production time and cost analyses
Dynamic alignment using external socket reaction moments in trans-tibial amputees
Background: Prosthetic alignment is used to optimize prosthetic functioning and comfort. Spatio-temporal and kinematic gait parameters are generally observed to guide this process. However, they have been shown to be influenced by compensations, which reduces their sensitivity to changes in alignment. Alternatively, the use of moments working at the base of the prosthetic socket, external socket reaction moments (ESRM), has been proposed to quantify prosthetic alignment. Research question: To investigate if a predetermined kinetic alignment criterion, 0Nm averaged over the stance phase, can be used to fine-tune prosthetic alignment. Methods: 10 transtibial amputees were included in this intervention study. Firstly, their prostheses were aligned using conventional alignment procedures. Kinetic parameters and Socket Comfort Score (SCS) were measured in this initial alignment (IA) condition. Subsequently, the coronal plane ESRM during gait was presented to the prosthetist in real time using a Gait Real-time Analysis Interactive Lab. The prosthetist iteratively adapted the prosthetic alignment towards a predetermined average ESRM during the stance phase of 0 Nm. At the Final Alignment (FA), kinetic parameters and SCS were measured again and a paired sample t-test was performed to compare ESRMs and SCSs between alignments. Results: A significant (p < 0.001) change was found in the absolute coronal plane ESRM (mean ± SD) from IA (|0.104| ± 0.058 Nm/kg) to FA (|0.012| ± 0.015 Nm/kg). In addition a significant (p < 0.001) change of the external coronal adduction knee moments was observed from IA (−0,127 ± 0.079 Nm/kg) to FA (−0.055 ± 0.089 Nm/kg), however this change was more variable among participants. On average, no significant (p = 0.37) change in the SCS was observed. Significance: While this study shows the potential of quantifying and guiding alignment with the assistance of kinetic criteria, it also suggests that a sole reliance on the ESRM as a single alignment criterion might be too simple
Integrated Modelling Frameworks for Environmental Assessment and Decision Support
As argued in Chapter 1, modern management of environmental resources defines problems from a holistic and integrated perspective, thereby imposing strong requirements on Environmental Decision Support Systems (EDSSs) and Integrated Assessment Tools (IATs). These systems and tools tend to be increasingly complex in terms of software architecture and computational power in order to cope with the type of problems they must solve. For instance, the discipline of Integrated Assessment (IA) needs tools that arc able to span a wide range of disciplines, from socio-economics to ecology to hydrology. Such tools must support a wide range of methodologies and techniques like agent-based modeling, Bayesian decision networks, optimization, multicriteria analyses and visualization tools, to name a few
Interstitial Cell Remodeling Promotes Aberrant Adipogenesis in Dystrophic Muscles.
Fibrosis and fat replacement in skeletal muscle are major complications that lead to a loss of mobility in chronic muscle disorders, such as muscular dystrophy. However, the in vivo properties of adipogenic stem and precursor cells remain unclear, mainly due to the high cell heterogeneity in skeletal muscles. Here, we use single-cell RNA sequencing to decomplexify interstitial cell populations in healthy and dystrophic skeletal muscles. We identify an interstitial CD142-positive cell population in mice and humans that is responsible for the inhibition of adipogenesis through GDF10 secretion. Furthermore, we show that the interstitial cell composition is completely altered in muscular dystrophy, with a near absence of CD142-positive cells. The identification of these adipo-regulatory cells in the skeletal muscle aids our understanding of the aberrant fat deposition in muscular dystrophy, paving the way for treatments that could counteract degeneration in patients with muscular dystrophy
Cholecystectomy Risk in Crohn’s Disease Patients After Ileal Resection: a Long-term Nationwide Cohort Study
Background: The risk of gallstone disease necessitating cholecystectomy after ileal resection (IR) in Crohn’s disease (CD) patients is not well established. We studied the incidence, cumulative and relative risk of cholecystectomy after IR in CD patients, and associated risk factors. Methods: CD patients with a first IR between 1991 and 2015 were identified in PALGA, a nationwide pathology database in the Netherlands. Details on subsequent cholecystectomy and IR were recorded. Yearly cholecystectomy rates from the general Dutch population were used as a reference. Results: A cohort of 8302 (3466 (41.7%) males) CD patients after IR was identified. During the 11.9 (IQR 6.3–18.0) years median follow-up, the post-IR incidence rate of cholecystectomy was 5.2 (95% CI 3.5–6.4)/1000 persons/year. The cumulative incidence was 0.5% at 1 year, 2.4% at 5 years, 4.6% at 10 years, and 10.3% after 20 years. In multivariable analyses, female sex (HR 1.9, CI 1.5–2.3), a later calendar year of first IR (HR/5-year increase, HR 1.27, CI 1.18–1.35), and ileal re-resection (time-dependent HR 1.37, CI 1.06–1.77) were associated with cholecystectomy. In the last decade, cholecystectomy rates increased and were higher in our postoperative CD population than in the general population (relative incidence ratio 3.13 (CI 2.29–4.28; p < 0.0001) in 2015). Conclusions: Although higher in females, increasing in recent years, and higher than in the general population, the overall risk of cholecystectomy in CD patients following IR is low and routine prophylactic measures seem unwarranted
Potential determinants of antibody responses after vaccination against SARS-CoV-2 in older persons: the Doetinchem Cohort Study
Background: Immune responses to vaccination vary widely between individuals. The aim of this study was to identify health-related variables potentially underlying the antibody responses to SARS-CoV-2 vaccination in older persons. We recruited participants in the long-running Doetinchem Cohort Study (DCS) who underwent vaccination as part of the national COVID-19 program, and measured antibody concentrations to SARS-CoV-2 Spike protein (S1) and Nucleoprotein (N) at baseline (T0), and a month after both the first vaccination (T1), and the second vaccination (T2). Associations between the antibody concentrations and demographic variables, including age, sex, socio-economic status (SES), comorbidities (cardiovascular diseases and immune mediated diseases), various health parameters (cardiometabolic markers, inflammation markers, kidney- and lung function) and a composite measure of frailty (‘frailty index’, ranging from 0 to 1) were tested using multivariate models. Results: We included 1457 persons aged 50 to 92 years old. Of these persons 1257 were infection naïve after their primary vaccination series. The majority (N = 954) of these individuals were vaccinated with two doses of BNT162b2 (Pfizer) and their data were used for further analysis. A higher frailty index was associated with lower anti-S1 antibody responses at T1 and T2 for both men (R T1 = -0.095, P T1 = 0.05; R T2 = -0.11, P T2 = 0.02) and women (R T1 = -0.24, P T1 < 0.01; R T2 = -0.15, P T2 < 0.01). After correcting for age and sex the frailty index was also associated with the relative increase in anti-S1 IgG concentrations between the two vaccinations (β = 1.6, P < 0.01). Within the construct of frailty, history of a cardiac catheterization, diabetes, gastrointestinal disease, a cognitive speed in the lowest decile of the population distribution, and impaired lung function were associated with lower antibody responses after both vaccinations. Conclusions: Components of frailty play a key role in the primary vaccination response to the BNT162b2 vaccine within an ageing population. Older persons with various comorbidities have a lowered immune response after their first vaccination, and while frail and sick older persons see a stronger increase after their second vaccination compared to healthy people, they still have a lower antibody response after their second vaccination
- …