22 research outputs found
Recommended from our members
Catheter ablation vs. antiarrhythmic drug therapy in patients with symptomatic atrioventricular nodal re-entrant tachycardia: a randomized, controlled trial.
Aims: To conduct a randomized trial in order to guide the optimum therapy of symptomatic atrioventricular nodal re-entrant tachycardia (AVNRT). Methods and Results: Patients with at least one symptomatic episode of tachycardia per month and an electrophysiologic diagnosis of AVNRT were randomly assigned to catheter ablation or chronic antiarrhythmic drug (AAD) therapy with bisoprolol (5 mg od) and/or diltiazem (120-300 mg od). All patients were properly educated to treat subsequent tachycardia episodes with autonomic manoeuvres or a 'pill in the pocket' approach. The primary endpoint of the study was hospital admission for persistent tachycardia cardioversion, during a follow-up period of 5 years. Sixty-one patients were included in the study. In the ablation group, 1 patient was lost to follow-up, and 29 were free of arrhythmia or conduction disturbances at a 5-year follow-up. In the AAD group, three patients were lost to follow-up. Of the remainder, 10 patients (35.7%) continued with initial therapy, 11 patients (39.2%) remained on diltiazem alone, and 7 patients (25%) interrupted their therapy within the first 3 months following randomization, and subsequently developed an episode requiring cardioversion. During a follow-up of 5 years, 21 patients in the AAD group required hospital admission for cardioversion. Survival free from the study endpoint was significantly higher in the ablation group compared with the AAD group (log-rank test, P < 0.001). Conclusions: Catheter ablation is the therapy of choice for symptomatic AVNRT. Antiarrhythmic drug therapy is ineffective and not well tolerated
Anatomical Ablation of the Atrioventricular Node
\ua9 The Author(s) 2024. Background: Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe. Methods: The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria. Results: Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50–70 minutes) of procedure time, 3.4 minutes (IQR 2.4–5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3–6) RF lesions. Αn escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8–15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5–14 months) of follow-up. Conclusion: Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation
Use of a circular mapping and ablation catheter for ablation of atypical right ventricular outflow tract arrhythmia
Remote ischemic preconditioning is feasible in ad hoc percutaneous coronary interventions
Antiendothelial cell antibodies in patients with coronary artery ectasia
BACKGROUND: The mechanisms involved in the pathogenesis of coronary artery ectasia (CAE) have not been elucidated. Circulating antiendothelial cell antibodies (AECA) are often detectable in systemic vasculitis and have been implicated in the pathogenesis of endothelial injury. Their prevalence in CAE is not known. METHODS AND Results: Out of 475 consecutive patients subjected to coronary angiography, 27 patients were diagnosed with CAE. Thirty patients matched for age, body mass index, sex, and coronary artery disease prevalence, served as controls. Serum AECA of IgG, IgM, and IgA isotypes were detected using a cell-based enzyme-linked immunosorbent assay (ELISA). Antinuclear antibodies (ANA) and antineutrophil cytoplasmic antibodies (ANCA) were detected using indirect immunofluorescence. IgG and IgM anticardiolipin antibodies (aCL) were detected using commercial ELISA. The prevalence of ANA and ANCA was similar in CAE patients and controls (33.3 vs. 43.3%, and 3.3 vs. 7.4%, respectively). There was no significant difference in IgG or IgM aCL reactivity between patients and controls. Both CAE patients and controls were negative for IgG AECA. The frequency of IgM AECA positivity was similar in CAE patients and controls. The prevalence of AECA of the IgA isotype was significantly higher in CAE patients (37.0 vs. 10%, P<0.05). Conclusion: There is increased prevalence of circulating AECA of the IgA isotype in patients with CAE. This provides evidence for a role of autoimmunity in the pathogenesis of certain cases of CAE. Copyright © 2010 Lippincott Williams & Wilkins
587 Slow pathway ablation in atrioventricular nodal reentrant tachycardia modifies the electrophysiologic characteristics of the inferior atrial inputs to the human atrioventricular node
Patient dosimetry during coronary interventions: A comprehensive analysis
Background We performed a detailed analysis of patient radiation during
coronary interventions, comparing dose measurements to established dose
reference levels, assessing coronary artery doses, and estimating total
radiation risk of fatal cancer.
Methods We prospectively examined 281 patients who were subjected to 307
percutaneous coronary interventions.
Results The mean kerma area product (KAP) per procedure was 82.1 +/-
47.9 Gy. cm(2). Corresponding values for fluoroscopy and digital
cineangiography were 28.3 +/- 25.5 Gy cm(2) and 53.8 +/- 35.5 Gy. cm(2),
respectively, and exposure times were 13.1 +/- 6.8 minutes (87%) and
2.0 +/- 1.5 minutes (13%), respectively. The right anterior oblique
caudal and left anterior oblique cranial projections accounted for the
highest amount of KAP (24.0% and 23.1%, respectively) compared with
other projections. The maximum recorded skin-dose was 182 mGy.
Performing a representative procedure on a phantom, the effective dose
was 14.9 mSv. The mean coronary dose was 61.7 +/- 38.2 mGy, with a
highest calculated dose of 220.1 mGy. The third quartile of KAP
measurements was 105 Gy. cm(2), the 95th percentile was 175 Gy. cm(2),
and the mean value of KAP measurements was 82 Gy.cm(2). The total risk
for the development of fatal cancer was calculated as 83 cases for every
100,000 patients subjected to coronary intervention.
Conclusions A detailed analysis of patient radiation during coronary
interventions is presented. Coronary doses and total radiation risk of
fatal cancer are also calculated, and a method for establishing dose
reference level values is proposed
Effect of slow pathway ablation in atrioventricular nodal reentrant tachycardia on the electrophysiologic characteristics of the inferior atrial inputs to the human atrioventricular node
The inferior atrial extensions of the atrioventricular (AV) node have been related to the anatomic substrate of the slow pathway, but their role in AV nodal reentrant tachycardia (AVNRT) is unknown. Ten patients with slow-fast AVNRT were studied before and after successful slow pathway ablation. Simultaneous His bundle recordings from the right and left sides of the septum were made during right and left inferoparaseptal pacing. Longer stimulus to His (St-H) intervals were measured during right inferoparaseptal pacing than during left inferoparaseptal pacing (284 +/- 55 vs 246 +/- 46 ms, p = 0.005 for right His recordings and 283 +/- 56 vs 244 +/- 46 ms, p = 0.005 for left His recordings) at similar coupling intervals during AVNRT induction. After ablation, the St-H intervals at the maximum AV nodal conduction decrement were similar during right inferoparaseptal and left inferoparaseptal pacing (217 +/- 32 vs 207 +/- 21 ms, p = 0.10 for right His and 215 +/- 32 vs 206 +/- 20 ms, p = 0.13 for left His) at similar coupling intervals. The difference (DeltaSt-H) between St-H intervals during AVRNT induction or at the maximum conduction decrement and during constant pacing for right His recordings with right inferoparaseptal pacing were significantly greater than DeltaSt-H measured with left His during left inferoparaseptal pacing (173 +/- 64 vs 137 +/- 55 ms, p = 0.005) before ablation, but not after (117 +/- 39 vs 100 +/- 40 ms, p = 0.44). Resetting of AVNRT with delivery of left inferoparaseptal extrastimuli was achieved in 7 of 10 patients. In conclusion, the electrophysiologic characteristics of the right and left inferior atrial inputs to the human AV node in patients with AVNRT and their response to slow pathway ablation provide further evidence that the inferior nodal extensions represent the anatomic substrate of the slow pathwa
Medical personnel and patient dosimetry during coronary angiography and intervention
Percutaneous coronary interventions are associated with increased radiation exposure compared to most radiological examinations. This prospective study aimed at (1) measuring entrance doses for all in-room personnel, (2) performing an assessment of patient effective dose and intracoronary doses, (3) investigating the contribution of each projection to kerma-area product (KAP) and irradiation time, (4) comparing results with established DRL values in this clinical setting and (5) estimating the risk for fatal cancer to patients and operators. Measurements were performed during 40 consecutive procedures of coronary angiography (CA), half of which were followed by ad hoc coronary angioplasty (PTCA). KAP measurements were used for patients and thermoluminescent dosimetry for the in-room personnel. The mean KAP value per procedure for CA was 29 ± 9 Gy cm2. Thirty four per cent of KAP was due to fluoroscopy, whereas the remainder (66%) was due to digital cine. Accordingly, the mean KAP value per PTCA procedure was 75 ± 30 Gy cm2, and contribution of fluoroscopy is 57%. Effective dose per year was estimated to be 0.04-0.05 mSv y-1 for the primary operator, and 0.03-0.04 mSv y-1 for those assisting. Corresponding measurements for radiographer and nurse were below detectable level, implying minimal radiation hazards for them. Regarding radiation exposure, coronary intervention is considered a quite safe procedure for both patients and personnel in laboratories with modern equipment and experienced operators as long as standard safety precautions are considered. Exposure optimization though should be constantly sought through continuous review of procedures
