30 research outputs found

    Aspects of GEANT4 Monte-Carlo calculations of the BC501A neutron detector

    No full text
    The response function of a commercial 2 in. x 2 in. BC501A neutron detector has been studied through the general-purpose Monte-Carlo (MC) simulation toolkit GEANT4. For neutron energies below 8 MeV, where the dominant detection mechanism originates from the knockout protons, the results of MC calculations reproduce remarkably well the experimental pulse-height spectra. This is not the case, however, at higher neutron energies, where the contribution of heavier charged particles to the detection mechanism becomes significant. The calculated detector efficiency is also compared at three indicative energies to the experimental one via the neutron activation technique. (c) 2007 Elsevier B.V. All rights reserved.status: publishe

    A gEUD-based inverse planning technique for HDR prostate brachytherapy: Feasibility study

    No full text
    Purpose: The purpose of this work was to study the feasibility of a new inverse planning technique based on the generalized equivalent uniform dose for image-guided high dose rate (HDR) prostate cancer brachytherapy in comparison to conventional dose-volume based optimization. Methods: The quality of 12 clinical HDR brachytherapy implants for prostate utilizing HIPO (Hybrid Inverse Planning Optimization) is compared with alternative plans, which were produced through inverse planning using the generalized equivalent uniform dose (gEUD). All the common dose-volume indices for the prostate and the organs at risk were considered together with radiobiological measures. The clinical effectiveness of the different dose distributions was investigated by comparing dose volume histogram and gEUD evaluators. Results: Our results demonstrate the feasibility of gEUD-based inverse planning in HDR brachytherapy implants for prostate. A statistically significant decrease in D10 orand final gEUD values for the organs at risk (urethra, bladder, and rectum) was found while improving dose homogeneity or dose conformity of the target volume. Conclusions: Following the promising results of gEUD-based optimization in intensity modulated radiation therapy treatment optimization, as reported in the literature, the implementation of a similar model in HDR brachytherapy treatment plan optimization is suggested by this study. The potential of improved sparing of organs at risk was shown for various gEUD-based optimization parameter protocols, which indicates the ability of this method to adapt to the users preferences. © 2013 American Association of Physicists in Medicine
    corecore