18 research outputs found

    A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)

    Get PDF
    Meeting abstrac

    Robust estimation of bacterial cell count from optical density

    Get PDF
    Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data

    SIM test results for aramid fibres

    No full text

    Creep and strength retention of aramid fibers

    No full text
    Creep tests at ambient conditions have been carried out on Kevlar 49 and Technora yarns covering a wide stress spectrum (10-70% average breaking load) for a long period of time (up to a year). The results confirm that Kevlar 49 and Technora yarns show a nonlinear behavior at stresses below 40% of the breaking load and a linear behavior at stresses above 40%. The strength retention following creep for Kevlar 49 and Technora has also been examined. The results show a significant difference in the behavior of the two materials. Kevlar 49 appears to lose strength almost linearly with time, while Technora seems to lose strength much more rapidly. These results would have significant implications for design. © 2012 Wiley Periodicals, Inc. J Appl Polym Sci, 2012 Copyright © 2012 Wiley Periodicals, Inc

    Stress limits for aramid fibres

    No full text

    Design criteria for aramid fibres

    No full text

    Accelerated and real-time creep and creep-rupture results for aramid fibers

    No full text
    This article presents results from conventional creep tests (CCT) and two accelerated test methods (the stepped isothermal method (SIM) and the stepped isostress method (SSM)) to determine the creep and creep-rupture behavior of two different aramid fibers, Kevlar 49 and Technora. CCT are regarded as the true behavior of the yarn, but they are impractical for long-term use where failures are expected only after many years. All the tests were carried out on the same batches of yarns, and using the same clamping arrangements, so the tests should be directly comparable. For both materials, SIM testing gives good agreement with CCT and gave stress-rupture lifetimes that followed the same trend. However, there was significant variation for SSM testing, especially when testing Technora fibers. The results indicate that Kevlar has a creep strain capacity that is almost independent of stress, whereas Technora shows a creep strain capacity that depends on stress. Its creep strain capacity is approximately two to three times that of Kevlar 49. The accelerated test methods give indirect estimates for the activation energy and the activation volume of the fibers. The activation energy for Technora is about 20% higher than that for Kevlar, meaning that it is less sensitive to the effects of increasing temperature. The activation volume for both materials was similar, and in both cases, stress dependent. Copyright © 2012 Wiley Periodicals, Inc