886 research outputs found

    Foreword

    Get PDF

    Relation between toughness, infinite fatigue life and microstructure in large blooms for automotive plastic molds.

    Get PDF
    Presentazione orale al European Congress on Advanced Material and Processes (Euromat 2005), Praga (R. Ceca), 5/10/2005 - 8/10/200

    Influenza delle condizioni di conservazione sulla qualità e sulla stabilità nel tempo di filetti di alici sott’olio.

    Get PDF
    The overall quality of semi-preserved anchovy fillets in oil is strongly dependent on the quality of the catch as well as on the manufacturing processes adopted by the fishing industry. The enzymatic processes underlying the fish ripening tend to remain also during the storage, especially if holding temperatures and packaging materials are inappropriate, thus being potentially responsible for the rapid loss of the sensorial properties of the fish product. In the present work the modification over time of different qualitative parameters of samples of anchovy fillets in oil stored in different packaging materials (glass and plastic) and at different temperatures (18 and 28°C) was instrumentally evaluated. The exposure to high temperature determined a rapid and widespread deterioration of the anchovy fillets, while no significant packaging-dependent modification of the organoleptic quality of the fish were identified

    The Present Development of CsI Rich Detectors for the ALICE Experiment at CERN

    Get PDF
    The ALICE Collaboration plans to implement a 12m^2 array consisting of 7 proximity focussed C6F^14 liquid radiator RICH modules devoted to the particle identification in the momentum range: 1 GeV/c - 3.5 GeV/c for pions and kaons. A large area CSI-RICH prototype has been designed and built with the aim to validate the detector parameter assumptions made to predict the performance of the High Momentum Particle Identification System (HMPID) of the ALICE Experiment. The main elements of the prototype will be described with emphasis on the engineering solutions adopted. First results from the analysis of multitrack events recorded with this prototype exposed to hadron beams at the CERN SPS will be discussedList of FiguresFigure 1 General view of the ALICE lay-outFigure 2 Schematic layout of the fast CsI-RICHFigure 3 Perspective view of the HMPID layout with the seven RICH modules tilted according to their position with respect to the interaction vertex. The frame that supports the detectors is also shownFigure 4 Top view of the photodetector anode plane with the wire support spacer. One CsI board, out of six forming the pad cathode plane, is also shown.Figure 5 Perspective view of the HMPID honeycomb panel with the three radiator vesselsFigure 6 Cut away view of the HMPID CsI-RICH showing separately each detector component. Kapton buses that carry signals from the pads to the readout electronics are also shownFigure 7 a)number of resolved photoelectrons per event, b)reconstructed Cherenkov angle per photonFigure 8 C6F14 transmission plots before and after the molecular sieve purificationFigure 9 Display plot showing an SPS event. Three tracks are reconstructed by using the tracking chamber telescope, the associated rings are shown in the HMPID prototypeThis publication also appears as INT-98-20

    A large area CsI RICH Detector in ALICE at LHC

    Get PDF
    A 1m2 CsI RICH prototype has been successfully tested in a hadron beam at CERN SPS. The prototype, fully equipped with 15k electronic channels, has been used to identify particles coming from pi-Be interactions. Track reconstruction has been performed by using a telescope consisting of four gas pad chambers. A detailed description of the detector will be presented and results from the test will be discussed.List of figuresFigure 1 Expected proton and antiproton yields including jet quenching mechanism in central Pb-Pb collisions at LHC.Figure 2 Schematic view of the HMPID CsI-RICHFigure 3 Experimental layout used at the SPS/H4 test beamFigure 4 Distributions of the mean number, per ring, of pad hits (Npad), electrons (Ntot) and Cherenkov photoelectrons (Nres) as a function of the single-electron mean pulse heightFigure 5 Mean single-electron pulse height as a function of high voltage measured at the centre of each of the four photocathodesFigure 6 Evaluation of the uniformity of the chamber gain for the photocathode PC32Figure 7 Azimuthal distribution of the photon pad hits in the Cherenkov fiducial zone (HV=2050 V)Figure 8 Photon angle (a) and track Cherenkov angle (b) distributions for beam events at the SPSFigure 9 Track density on the HMPID cathode plane in real 350 GeV/c pi--Be eventsFigure 10 Three dimensional display of an SPS 350 GeV/c pi--Be event. Eleven tracks are reconstructed in the telescope by requiring one hit on each pad chamber to reconstruct a track</UL

    Efficacy and Safety of Trifluridine/Tipiracil Treatment in Patients With Metastatic Gastric Cancer Who Had Undergone Gastrectomy: Subgroup Analyses of a Randomized Clinical Trial

    Get PDF
    Importance Trifluridine/tipiracil (FTD/TPI) treatment has shown clinical benefit in patients with pretreated metastatic gastric cancer or gastroesophageal junction cancer (mGC/GEJC). Patients who have undergone gastrectomy constitute a significant proportion of patients with mGC/GEJC. Objective To assess the efficacy and safety of FTD/TPI among patients with previously treated mGC/GEJC who had or had not undergone gastrectomy. Design, Setting, and Participants This preplanned subgroup analysis of TAGS (TAS-102 Gastric Study), a phase 3, randomized, placebo-controlled, clinical trial included patients with mGC/GEJC who had received at least 2 previous chemotherapy regimens, and was conducted at 110 academic hospitals in 17 countries in Europe, Asia, and North America, with enrollment between February 24, 2016, and January 5, 2018; the data cutoff was March 31, 2018. Interventions Patients were randomized 2:1 to receive oral FTD/TPI 35 mg/m2 twice daily or placebo twice daily with best supportive care on days 1 through 5 and days 8 through 12 of each 28-day treatment cycle. Main Outcomes and Measures The primary end point was overall survival. This subgroup analysis was conducted to examine potential trends and was not powered for statistical significance. Efficacy and safety end points were evaluated in the subgroups. Results Of 507 randomized patients (369 [72.8%] male; mean [SD] age, 62.5 [10.5] years), 221 (43.6%) had undergone gastrectomy (147 randomized to FTD/TPI and 74 to placebo) and 286 (56.4%) had not undergone gastrectomy (190 randomized to FTD/TPI and 96 to placebo). In the gastrectomy subgroup, the overall survival hazard ratio (HR) in the FTD/TPI group vs placebo group was 0.57 (95% CI, 0.41-0.79), and the progression-free survival HR was 0.48 (95% CI, 0.35-0.65). In the no gastrectomy subgroup, the overall survival HR in the FTD/TPI group vs placebo group was 0.80 (95% CI, 0.60-1.06), and the progression-free survival HR was 0.65 (95% CI, 0.49-0.85). Among FTD/TPI-treated patients, grade 3 or higher adverse events of any cause occurred in 122 of 145 patients (84.1%) in the gastrectomy subgroup and 145 of 190 (76.3%) in the no gastrectomy subgroup: 64 (44.1%) in the gastrectomy subgroup and 50 (26.3%) in the no gastrectomy subgroup had grade 3 or higher neutropenia, 31 (21.4%) in the gastrectomy subgroup and 33 (17.4%) in the no gastrectomy subgroup had grade 3 or higher anemia, and 21 (14.5%) in the gastrectomy subgroup and 10 (5.3%) in the no gastrectomy subgroup hD grade 3 or higher leukopenia. In the gastrectomy subgroup, 94 (64.8%) had dosing modifications because of adverse events vs 101 (53.2%) in the no gastrectomy subgroup; 15 (10.3%) in the gastrectomy group and 28 (14.7%) in the no gastrectomy group discontinued treatment because of adverse events. Treatment exposure was similar between groups. Conclusions and Relevance The FTD/TPI treatment was tolerable and provided efficacy benefits among patients with pretreated mGC/GEJC regardless of previous gastrectomy

    A progress report on the development of the CsI-RICH detector for the ALICE experiment at LHC

    Get PDF
    The particle identification in ALICE (A Large Ion Collider Experiment) at LHC will be achieved by two complementary systems based on time of flight measurement, at low ptp_t, and on the Ring Imaging Cherenkov (RICH) technique, at ptp_t ranging from 2 to 5 GeV/cc, respectively. The High Momentum PID (HMPID) system will cover \sim5\% of the phase space, the single arm detector array beeing composed by seven 1.3×\times1.3 m2^2 CsI-RICH modules placed at 4.7 m from the interaction point where a density of about 50 particles/m2^2 is expected.\\ A 1 m2^2 prototype, 2/3 of HMPID module size, has been successfully tested at the CERN/PS beam where 18 photoelectrons per event have been obtained with 3 GeV/c pions and 10 mm liquid C6F14\mathrm{C}_6\mathrm{F}_{14} radiator. Mechanical problems related to the liquid radiator vessel construction have been solved and the prototype, fully equipped, will be tested at the CERN/SPS to investigate the PID capability in high particle density events.\\ In this report, after an introductory discussion on the requirements for PID in ALICE, the HMPID prototype is described and the main results of beam tests on large area CsI photocathodes, operated in RICH detectors, are given

    Centrality dependence of the expansion dynamics in Pb-Pb collisions at 158 A GeV/c

    Get PDF
    Two-particle correlation functions of negatively charged hadrons from Pb-Pb collisions at 158 GeV/c per nucleon have been measured by the WA97 experiment at the CERN SPS. A Coulomb correction procedure that assumes an expanding source has been implemented. Within the framework of an expanding thermalized source model the size and dynamical state of the collision fireball at freeze-out have been reconstructed as a function of the centrality of the collision. Less central collisions exhibit a different dynamics than central ones: both transverse and longitudinal expansion velocities are slower, the expansion duration is shorter and the system freezes out showing smaller dimensions and higher temperature.Comment: 22 pages, 11 figures, Te
    corecore