7 research outputs found

    Estudo comparativo do método das pesagens e o método gravimétrico padrão para a determinação do teor de umidade do solo

    Get PDF
    In the present study, a comparison was made between the multiple-weighing method, in which a 500ml Erlenmeyer flask and a 0.lg precision balance are utilized, and the usual oven-drying method, considered an universal comparator for being the most accurate, in which the soil sample is placed to dry in an oven at 105-110°C for a period of 18-24 hours. In order to test the methods under study, samples of three different soils were utilized: Luiz de Queiroz Series, Sertãozinho Series and Monte Olimpo Series. The data obtained were analysed statistically and evidence was shown that a high correlation exists between the methods, with indices of 0.9719, 0.9458 and 0.9487, respectively.São comparados neste trabalho, o Método das Pesagens, no qual é utilizado um Erlenmeyer de 500ml de capacidade e uma balança com precisão de 0,lg, e o Método Gravimétrico Padrão, tido como comparador universal por ser o mais exato, no qual seca-se a amostra de solo em estufa a 105-110°C durante 18-24 horas. Para testar o método em questão, foram utilizados três solos, série Luiz de Queiroz, série Sertãozinho e série Monte Olimpo. Os dados obtidos foram tratados estatisticamente e os resultados obtidos pelos dois métodos foram semelhantes, com um índice de correlação de 0,9719, 0,9458 e 0,9489 respectivamente para os solos em questão

    Comparação de vários materiais de cobertura através de índices de conforto térmico

    Get PDF
    The thermal behaviour of different roof coating materials was studied through the thermal comfort index. For summer condictions the effect of the Globe and Humidity Index (ITGU) and the Radiant Thermal Load (CTR) were used to study the interior of shelters. Fiberglass, aluminum and zinc tiles were more recently introduced in this project. Other tested materials were clay, asbestos, cement and thermal tiles. To evaluate the comfort index the following measurements were performed: maximum and minimum temperatures, wind velocity, relative humidity and "black globe" temperature. The conclusions were: clay tiles continue being the most efficient and fiberglass tiles the least thermal efficient, and other tiles had an intermediate behaviour.O comportamento térmico de diferentes materiais de cobertura foi estudado através dos índices de conforto. Para as condições de verão, estudou-se o efeito do índice de Temperatura de Globo e Umidade (ITGU) e da Carga Térmica Radiante (CTR) no interior de abrigos. As telhas de fibra transparente, alumínio e zinco foram os mais recentes materiais inseridos neste projeto. Além delas, foram estudados os comportamentos das telhas de barro, cimento amianto e térmica. Para a avaliação dos índices de conforto foram registrados: temperatura máxima e mínima, velocidade do vento, umidade relativa e temperatura de globo negro. Concluiu-se que: a telha de barro continuou sendo a mais eficiente e a telha de fibra transparente a de menor eficiência térmica e as demais apresentaram um comportamento intermediário

    Estudo da influência da locação de uma edificação rural na carga térmica solar recebida pelas paredes

    Get PDF
    The purpose of this paper is to verifythe influence of a rural edification orientation on the radiant thermal load (solar radiation) intercepted byit. The authors examined two situations commonlyfound: the North-South and East-West orientations. In order to determine the radiant thermal load, so important in the ventilation and refrigeration problems, it was assumed a model of construction as an example and the proposed relations can be applied to anydesired construction model. The results show that the radiant thermal load from East-West reached 74% of the North-South exposure.O presente trabalho se propõe a verificar de que modo a orientação de uma edificação rural influe na carga térmica radiante (radiação solar) interceptada pela mesma. Duas situações freqüentemente encontradas na prática são examinadas: a orientação Norte-Sul e a Leste-Oeste. Para determinar a carga térmica radiante, de importância nos problemas deventilação e refrigeração, é adotado um modelo de construção a título de exemplo, sendo que as relações aqui propostas são aplicáveis a qualquer modelo de construção desejado. Os resultados mostraram quea carga térmica radiante da exposição Leste-Oeste chega a ser 74% da carga na exposição Norte-Sul

    Comparação de vários materiais de cobertura através de índices de conforto térmico Comparison of various roof coating materials through thermal comfort indexes

    Get PDF
    O comportamento térmico de diferentes materiais de cobertura foi estudado através dos índices de conforto. Para as condições de verão, estudou-se o efeito do índice de Temperatura de Globo e Umidade (ITGU) e da Carga Térmica Radiante (CTR) no interior de abrigos. As telhas de fibra transparente, alumínio e zinco foram os mais recentes materiais inseridos neste projeto. Além delas, foram estudados os comportamentos das telhas de barro, cimento amianto e térmica. Para a avaliação dos índices de conforto foram registrados: temperatura máxima e mínima, velocidade do vento, umidade relativa e temperatura de globo negro. Concluiu-se que: a telha de barro continuou sendo a mais eficiente e a telha de fibra transparente a de menor eficiência térmica e as demais apresentaram um comportamento intermediário.<br>The thermal behaviour of different roof coating materials was studied through the thermal comfort index. For summer condictions the effect of the Globe and Humidity Index (ITGU) and the Radiant Thermal Load (CTR) were used to study the interior of shelters. Fiberglass, aluminum and zinc tiles were more recently introduced in this project. Other tested materials were clay, asbestos, cement and thermal tiles. To evaluate the comfort index the following measurements were performed: maximum and minimum temperatures, wind velocity, relative humidity and "black globe" temperature. The conclusions were: clay tiles continue being the most efficient and fiberglass tiles the least thermal efficient, and other tiles had an intermediate behaviour