Empirical Assessment of Breast Lesion Detection Capability Through an Innovative Microwave Imaging Device
This paper investigates the effect of conductivity weighting on microwave images obtained through a dedicated imaging device. MammoWave is a microwave imaging device for detection of breast lesions, operating using only two azimuthally rotating antennas without the use of matching liquids. For each breast, a set of conductivity weighted images are generated
through modifying our algorithm based on Huygens principle, producing intensity maps representing the homogeneity of tissues’ dielectric properties. Subsequently, we introduce several imaging parameters (i.e. features) to quantify the non-homogenous behaviour of the image. Through empirical investigation on 103 breasts, we can verify that a selection of these features could allow distinction between breasts with radiological findings (WF), i.e. with benign or malign lesions, and breasts with no radiological findings (NF). Statistical significance was set at p<0.05.We obtained single features Area Under the receiver operating characteristic Curves (AUCs) spanning from 0.65 to 0.68. Significantly, we achieve AUCs of up to 0.77 when considering dense breasts only, which tend to cause detection limitations in mammography exams
Recommended from our members
Numerical and Experimental Analysis of Transient Flow in Roots Blower
The performance of rotary positive displacement machines highly depends on the operational clearances. It is widely believed that computational fluid dynamics (CFD) can help understanding internal leakage flows. Developments of grid generating tools for analysis of leakage flows by CFD in rotary positive displacement machines have not yet been fully validated. Roots blower is a good representative of positive displacement machines and as such is convenient for optical access in order to analyse internal flows. The experimental investigation of flow in optical roots blower by phase-locked PIV (Particle Image Velocimetry) performed in the Centre for Compressor Technology at City, University of London provided the velocity field suitable for validation of the simulation model. This paper shows the results of the three-dimensional CFD transient simulation model of a Roots blower with the dynamic numerical grids generated by SCORG and flow solution solved in ANSYS CFX flow solver to obtain internal flow patterns. The velocity fields obtained by simulation agree qualitatively with the experimental results and show the correct main flow features in the working chamber. There are some differences in the velocity magnitude and vortex distribution. The flow field in roots blower is highly turbulent and three-dimensional. The axial clearances should be included, and the axial grids should be refined in the simulation method. The paper outlines some directions for future simulation and experimental work. The work described in this paper is a part of the large project set to evaluate characteristics of the internal flow in rotary positive displacement machines and to characterize leakage flow
Recommended from our members
Experimental Investigation of the Transient Flow in Roots Blower
Rotary positive displacement machines are common method to pump flow in various process industries. Their performance highly depends on the operational clearances. It is widely believed that computational fluid dynamics (CFD) can help understanding and reducing internal leakage flows. However, Developments of grid generating tools for use of CFD in rotary positive displacement machines have not yet been fully validated. Thereby arising a need to validate these models that help in better understanding of the leakage flows. Roots blower is a good representative of positive displacement machines and as such is convenient for optical access to analyse flows in in such machines. This paper describes the setup of the experimental test rig with the optical Roots blower in the Centre for Compressor Technology at City, University of London and the first results obtained using three different flow visualization methods. These are namely i) the high-speed camera (HC), ii) the continuous time resolved PIV (CPIV) and iii) the instantaneous PIV obtained with double pulse PIV laser and double shutter camera (IPIV). Test results from these three tests are compared and discussed in the paper. The CPIV test shows the movement of the vortex and the general shape of the flow field clearly but is not sufficient to calculate velocity vectors of high-velocity particles due to the limitation of the laser and camera. The IPIV test can produce quantitative velocity vector images of the internal flow but needs improvement to look into the leakage flow. The work described in this paper is a part of the large project set to evaluate characteristics of the internal flow in rotary positive displacement machines and to characterize leakage flows. The objective is to enable further improvements in 3D CFD analysis of leakage flows in rotary positive displacement machines and ultimately lead to the improvement in the performance of rotary positive displacement machines
Dataset related to "A multicentric, single arm, prospective, stratified clinical investigation to evaluate MammoWave’s ability in breast lesions detection"
Microwave imaging is a safe and promising new technology in breast radiology, avoiding discomfort of breast compression and usage of ionizing radiation. This dataset relates to a paper which presents the first prospective microwave breast imaging study during which both symptomatic and asymptomatic subjects were recruited. Specifically, a prospective multicentre international clinical trial was performed in 2020-2021, to investigate the capability of a microwave imaging device (MammoWave) in allowing distinction between breasts with no radiological finding (NF) and breasts with radiological findings (WF), i.e., with benign or malignant lesions. Each breast scan was performed with the volunteers lying on a dedicated examination table in a comfortable prone position. MammoWave output was compared to reference standard (i.e., radiologic study obtained within the last month and integrated with histological one if available and deemed necessary by responsible investigator) to classify breasts into NF/WF categories. MammoWave output consists of a selection of microwave images’ features (determined prior to trials’ start), which allow distinction between NF and WF breasts (using statistical significance p<0.05). 353 women were enrolled in the study (mean age 51 years ± 12 [SD], minimum age 19, maximum age 78); MammoWave data from the first 15 women of each site, all with NF breasts, were used for calibration. Following central assessor evaluation, 111 NF (48 dense) and 272 WF (136 dense) breasts were used for comparison with MammoWave output. 272 WF comprised 182 benign findings and 90 malignant histology-confirmed cancer. A sensitivity of 82.3% was achieved (95%CI: 0.78-0.87); sensitivity is maintained when limiting the investigation to histology-confirmed breasts cancer only (90 histology-confirmed breasts cancer have been included in this analysis, having sizes ranging from 3 mm to 60 mm). Specificity value of approximately 50% was achieved as expected, since thresholds were calculated (for each feature) using median value obtained after recruiting the first 15 women (of each site), all NF. This prospective trial may represent another step for introducing microwave imaging into clinical practice, for helping in breast lesion identification in asymptomatic women
UWB device for breast microwave imaging: phantom and clinical validations
Microwave imaging has received increasing attention in the last decades, motivated by its application in diagnostic imaging. Such effort has been encouraged by the fact that, at microwave frequencies, it is possible to distinguish between tissues with different dielectric properties. In such framework, a novel microwave device is presented here. The apparatus, consisting of two antennas operating in air, is completely safe and non-invasive since it does not emit any ionizing radiation and it can be used for breast lesion detection without requiring any breast crushing. We use Huygens Principle to provide a novel understanding into microwave imaging; specifically, the algorithm based on this principle provides images which represent homogeneity maps of the dielectric properties (dielectric constant and/or conductivity). The experimental results on phantoms having inclusions with different dielectric constants are presented here. In addition, the capability of the device to detect breast lesions has been verified through clinical examinations on 51 breasts. We introduce a metric to measure the non-homogeneous behaviour of the image, establishing a modality to detect the presence of inclusions inside phantoms and, similarly, the presence of a lesion inside a breast
A multicentric, single arm, prospective, stratified clinical investigation to evaluate MammoWave’s ability in breast lesions detection
Microwave imaging is a safe and promising new technology in breast radiology, avoiding discomfort of breast compression and usage of ionizing radiation. This paper presents the first prospective microwave breast imaging study during which both symptomatic and asymptomatic subjects were recruited. Specifically, a prospective multicentre international clinical trial was performed in 2020-2021, to investigate the capability of a microwave imaging device (MammoWave) in allowing distinction between breasts with no radiological finding (NF) and breasts with radiological findings (WF), i.e., with benign or malignant lesions. Each breast scan was performed with the volunteers lying on a dedicated examination table in a comfortable prone position. MammoWave output was compared to reference standard (i.e., radiologic study obtained within the last month and integrated with histological one if available and deemed necessary by responsible investigator) to classify breasts into NF/WF categories. MammoWave output consists of a selection of microwave images’ features (determined prior to trials’ start), which allow distinction between NF and WF breasts (using statistical significance p<0.05). 353 women were enrolled in the study (mean age 51 years ± 12 [SD], minimum age 19, maximum age 78); MammoWave data from the first 15 women of each site, all with NF breasts, were used for calibration. Following central assessor evaluation, 111 NF (48 dense) and 272 WF (136 dense) breasts were used for comparison with MammoWave output. 272 WF comprised 182 benign findings and 90 malignant histology-confirmed cancer. A sensitivity of 82.3% was achieved (95%CI: 0.78-0.87); sensitivity is maintained when limiting the investigation to histology-confirmed breasts cancer only (90 histology-confirmed breasts cancer have been included in this analysis, having sizes ranging from 3 mm to 60 mm). Specificity value of approximately 50% was achieved as expected, since thresholds were calculated (for each feature) using median value obtained after recruiting the first 15 women (of each site), all NF. This prospective trial may represent another step for introducing microwave imaging into clinical practice, for helping in breast lesion identification in asymptomatic women
3D Huygens Principle based Microwave Imaging through MammoWave Device: Validation through Phantoms.
This work focuses on developing a 3D microwave imaging (MWI) algorithm based on the Huygens principle (HP). Specifically, a novel, fast MWI device (MammoWave) has been presented and exploited for its capabilities of extending image reconstruction from 2D to 3D. For this purpose, dedicated phantoms containing 3D structured inclusion have been prepared with mixtures having different dielectric properties. Phantom measurements have been performed at multiple planes along the z-axis by simultaneously changing the transmitter and receiver antenna height via the graphic user interface (GUI) integrated with MammoWave. We have recorded the complex S21 multi-quote data at multiple planes along the z-axis. The complex multidimensional raw data has been processed via an enhanced HP-based image algorithm for 3D image reconstruction. This paper demonstrates the successful detection and 3D visualization of the inclusion with varying dimensions at multiple planes/cross-sections along the z-axis with a dimensional error lower than 7.5%. Moreover, the paper shows successful detection and 3D visualization of the inclusion in a skull-mimicking phantom having a cylindrically shaped inclusion, with the location of the detected inclusion in agreement with the experimental setup. Additionally, the localization of a 3D structured spherical inclusion has been shown in a more complex scenario using a 3-layer cylindrically shaped phantom, along with the corresponding 3D image reconstruction and visualization
Novel microwave apparatus for breast lesions detection: Preliminary clinical results
This paper presents preliminary results of an innovative microwave imaging apparatus for breast lesions detection. Specially, a Huygens Principle based method is employed to process the microwave signals and to build the respective microwave images. The apparatus has been first tested on phantoms. Next, its performance has been verified through clinical examinations on 22 healthy breasts and on 29 breast having lesions, using as gold standard the output of the radiologist study review obtained using conventional techniques. Specifically, we introduce a metric, which is the ratio between maximum and average of the image intensity (MAX/AVG). We found that MAX/AVG of microwave images can be used for classifying breasts containing lesions. In addition, using MAX/AVG as classification parameter, receiver operating characteristic curves have been empirically determined. Furthermore, for one randomly selected breast having lesion, we have demonstrated that the localisation of the inclusion acquired through microwave imaging is compatible with mammography images
Microwave imaging for stroke detection: validation on head-mimicking phantom
This paper provides initial results on the efficacy of Huygens Principle (HP) microwave imaging for haemorrhagic stroke detection. This is done using both simulations and measurements in an anechoic chamber. Microstrip antennas operating between 1 and 2 GHz have been designed, constructed and used for imaging a human head model in Computer Simulation Technology (CST) software. A 3D model consisting of human head tissues of Ella is employed in the simulation. An emulated haemorrhagic stroke with the dielectric properties equivalent to the blood has been inserted in Ella. Moreover, a 3-layered head-mimicking phantom containing an inclusion has been constructed. Frequency-domain measurements have been performed in an anechoic chamber using a Vector Network Analyser arrangement to obtain the transfer function (S21) between two antennas. Both simulations and measurements show that the HP based technique may be used for haemorrhagic stroke detection. Among linear scattering techniques, the HP based technique allows to detect dielectric inhomogeneities in the frequency domain. HP can also be used if the antennas and phantom are in free space, i.e. no coupling liquid is required. Detection of the haemorrhagic stroke has been achieved after removing the artefacts. Artefact removal is an essential step of any microwave imaging system and current artefact removal approaches have been shown to be ineffective in the specific scenario of brain imaging. However, one of this paper’s novel contributions is the proposal of an artefact removal algorithm based on a subtraction between S21 obtained using measurements, which achieves improved performance while having a much lower computational complexity
Simulation study on the impact of the transmission power on the performance of routing protocols under different mobility models
© 2014 IEEE. the dynamic topology of a mobile ad hoc network poses a real challenge in designing the routing protocol. This paper examine through simulation the fundamental factors, mobility models and transmission power which have a major impacts on the performance of position based routing protocols. We analyse the effect of the transmission power of on the performance of protocols under two different mobility models. Using OPNET simulation tool, results show the evaluation and performance of the proposed protocol under a unified simulation environment for different scenarios
- …