3 research outputs found

    Correlation between Laser Fluorescence Readings and Volume of Tooth Preparation in Incipient Occlusal Caries In Vitro

    Full text link
    This study evaluated the correlation between laser fluorescence readings and the extent of incipient occlusal caries as measured by the volume of tooth preparation in vitro.One hundred and three permanent molars and premolars containing incipient occlusal pit-and-fissure caries and sound occlusal surfaces (1/4 of the sample, control) were selected. DIAGNOdent (KaVo Dental Corporation, Lake Zurich, IL, USA) readings were obtained according to manufacturer instructions. Caries was removed with 1/4 round burs in high speed. The volume of tooth preparation was measured using a surrogate measure based on the amount of composite needed to fill the preparations. Sensitivity and specificity using different cutoff values were calculated for lesions/preparations extending into dentin. The results were analyzed statistically.The Pearson correlation for preparation volume and DIAGNOdent reading measurements was low ( r  = 0.285). Sensitivity and specificity of DIAGNOdent for detection of dentinal lesions were 0.83 and 0.60, and 0.66 and 0.73 for the cutoff values of 20 and 30, respectively.Within the limitations of this study, laser fluorescence measured with DIAGNOdent does not correlate well with extent of carious tooth structure in incipient occlusal caries.Clinicians should not rely only on DIAGNOdent readings to determine the extension of incipient occlusal caries.( J Esthet Restor Dent 22:31–41, 2010)Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/78687/1/j.1708-8240.2009.00309.x.pd

    Primary screening of blood donors by nat testing for HCV-RNA: development of an "in-house" method and results Triagem primária de doadores de sangue por teste de ácidos nucléicos: desenvolvimento de um método não-comercial e resultados

    Get PDF
    An "in-house" RT-PCR method was developed that allows the simultaneous detection of the RNA of the Hepatitis C Virus (HCV) and an artificial RNA employed as an external control. Samples were analyzed in pools of 6-12 donations, each donation included in two pools, one horizontal and one vertical, permitting the immediate identification of a reactive donation, obviating the need for pool dismembering. The whole process took 6-8 hours per day and results were issued in parallel to serology. The method was shown to detect all six HCV genotypes and a sensitivity of 500 IU/mL was achieved (95% hit rate). Until July 2005, 139,678 donations were tested and 315 (0.23%) were found reactive for HCV-RNA. Except for five false-positives, all 310 presented the corresponding antibody as well, so the yield of NAT-only donations was zero, presenting a specificity of 99.83%. Detection of a window period donation, in the population studied, will probably demand testing of a larger number of donations. International experience is showing a rate of 1:200,000 - 1:500,000 of isolated HCV-RNA reactive donations.<br>Desenvolveu-se uma metodologia própria ("in-house") baseada em RT-PCR, que permite detectar simultaneamente o RNA do vírus HCV e de um RNA artificial empregado como controle externo. As amostras são analisadas em pools de 6-12 doações, cada doação sendo incluída em dois pools diferentes, um horizontal e um vertical, permitindo a identificação imediata de uma doação reativa, sem a necessidade de desmembrar-se um pool reativo. O processo todo consumiu de 6-8 horas diárias e os resultados foram emitidos em paralelo à sorologia. O método detectou os seis genótipos de HCV, com um limite de sensibilidade de 500 UI/mL (95% hit rate). Até julho de 2005 haviam sido testadas 139.678 doações com a detecção de 315 (0,23%) doações reativas para HCV-RNA. Exceto cinco falso-positivas, todas estas doações também apresentavam o respectivo anticorpo, portanto não se detectou nenhuma doação em janela imunológica. A especificidade foi de 99,83%. A detecção de amostra em janela imunológica, nesta população de doadores, provavelmente demandará a análise de um número maior de doações, espelhando-se na experiência internacional que tem mostrado a detecção de amostras HCV-RNA isoladas em 1:200.000 - 1:500.000 doações
    corecore