73 research outputs found

    Cost-utility of transcatheter aortic valve implantation for inoperable patients with severe aortic stenosis treated by medical management: a UK cost-utility analysis based on patient-level data from the ADVANCE study.

    Get PDF
    OBJECTIVE: To use patient-level data from the ADVANCE study to evaluate the cost-effectiveness of transcatheter aortic valve implantation (TAVI) compared to medical management (MM) in patients with severe aortic stenosis from the perspective of the UK NHS. METHODS: A published decision-analytic model was adapted to include information on TAVI from the ADVANCE study. Patient-level data informed the choice as well as the form of mathematical functions that were used to model all-cause mortality, health-related quality of life and hospitalisations. TAVI-related resource use protocols were based on the ADVANCE study. MM was modelled on publicly available information from the PARTNER-B study. The outcome measures were incremental cost-effectiveness ratios (ICERs) estimated at a range of time horizons with benefits expressed as quality-adjusted life-years (QALY). Extensive sensitivity/subgroup analyses were undertaken to explore the impact of uncertainty in key clinical areas. RESULTS: Using a 5-year time horizon, the ICER for the comparison of all ADVANCE to all PARTNER-B patients was £13 943 per QALY gained. For the subset of ADVANCE patients classified as high risk (Logistic EuroSCORE >20%) the ICER was £17 718 per QALY gained). The ICER was below £30 000 per QALY gained in all sensitivity analyses relating to choice of MM data source and alternative modelling approaches for key parameters. When the time horizon was extended to 10 years, all ICERs generated in all analyses were below £20 000 per QALY gained. CONCLUSION: TAVI is highly likely to be a cost-effective treatment for patients with severe aortic stenosis

    Treatment of aortic stenosis with a self-expanding transcatheter valve: the International Multi-centre ADVANCE Study

    Get PDF
    Aim Transcatheter aortic valve implantation has become an alternative to surgery in higher risk patients with symptomatic aortic stenosis. The aim of the ADVANCE study was to evaluate outcomes following implantation of a self-expanding transcatheter aortic valve system in a fully monitored, multi-centre ‘real-world' patient population in highly experienced centres. Methods and results Patients with severe aortic stenosis at a higher surgical risk in whom implantation of the CoreValve System was decided by the Heart Team were included. Endpoints were a composite of major adverse cardiovascular and cerebrovascular events (MACCE; all-cause mortality, myocardial infarction, stroke, or reintervention) and mortality at 30 days and 1 year. Endpoint-related events were independently adjudicated based on Valve Academic Research Consortium definitions. A total of 1015 patients [mean logistic EuroSCORE 19.4 ± 12.3% [median (Q1,Q3), 16.0% (10.3, 25.3%)], age 81 ± 6 years] were enrolled. Implantation of the CoreValve System led to a significant improvement in haemodynamics and an increase in the effective aortic valve orifice area. At 30 days, the MACCE rate was 8.0% (95% CI: 6.3-9.7%), all-cause mortality was 4.5% (3.2-5.8%), cardiovascular mortality was 3.4% (2.3-4.6%), and the rate of stroke was 3.0% (2.0-4.1%). The life-threatening or disabling bleeding rate was 4.0% (2.8-6.3%). The 12-month rates of MACCE, all-cause mortality, cardiovascular mortality, and stroke were 21.2% (18.4-24.1%), 17.9% (15.2-20.5%), 11.7% (9.4-14.1%), and 4.5% (2.9-6.1%), respectively. The 12-month rates of all-cause mortality were 11.1, 16.5, and 23.6% among patients with a logistic EuroSCORE ≤10%, EuroSCORE 10-20%, and EuroSCORE >20% (P< 0.05), respectively. Conclusion The ADVANCE study demonstrates the safety and effectiveness of the CoreValve System with low mortality and stroke rates in higher risk real-world patients with severe aortic stenosi

    Use of a Repositionable and Fully Retrievable Aortic Valve in Routine Clinical Practice: The RESPOND Study and RESPOND Extension Cohort

    Get PDF
    Objectives: The authors sought to evaluate 1-year clinical outcomes with the Lotus valve (Boston Scientific, Marlborough, Massachusetts) in a large international, multicenter prospective registry including patients eligible for transcatheter aortic valve replacement (TAVR) based on heart team consensus. Background: TAVR is a safe and effective treatment for severe aortic valve stenosis; however, limited data are available on TAVR with the repositionable and fully retrievable Lotus valve in unrestricted contemporary clinical practice. Methods: The RESPOND (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes) study enrolled 1,014 patients; 996 patients were implanted with the Lotus valve (mean age 80.8 years, 50.8% female, mean STS score 6.0 ± 6.9%). The primary endpoint was all-cause mortality in the intent-to-treat population at 30 days and 1 year. An Extension cohort of 50 patients was treated with the Lotus valve with Depth Guard including a modified delivery system. Mortality and stroke were independently adjudicated. An independent core laboratory assessed echocardiographic data. Results: One-year clinical follow-up was available for 99.9% of Lotus valve-treated patients. At 1 year, the all-cause mortality rate was 11.7% and 4.1% of patients had experienced a disabling stroke. The permanent pacemaker implantation rate was 32% (37% among pacemaker-naive patients). Echocardiographic data at 1 year were available for core laboratory assessment in 62.6% of patients. Paravalvular leak was absent or trace in 94.5%, mild in 5.1%, and moderate in 0.4% of patients. Data from the Extension cohort confirmed good clinical outcomes at 30 days with an 18% permanent pacemaker rate (20% among pacemaker-naive patients). Conclusions: One-year outcomes from the RESPOND study confirm the safety and efficacy of the Lotus valve when used in routine clinical practice. (Repositionable Lotus Valve System—Post-Market Evaluation of Real World Clinical Outcomes [RESPOND]; NCT02031302

    Clinical outcomes of the Lotus Valve in patients with bicuspid aortic valve stenosis: An analysis from the RESPOND study

    Get PDF
    Aims: Patients with bicuspid valves represent a challenging anatomical subgroup for transcatheter aortic valve implantation (TAVI). This analysis evaluated the clinical outcomes of the fully repositionable and retrievable Lotus Valve System in patients with bicuspid aortic valves enrolled in the RESPOND post-market registry. Methods and Results: The prospective, open-label RESPOND study enrolled 1,014 patients at 41 centers in Europe, New Zealand, and Latin America, 31 (3.1%) of whom had bicuspid aortic valves. The mean age in the bicuspid patient cohort was 76.4 years, 64.5% were male, and the baseline STS score was 6.0 ± 10.2. Procedural success was 100%, with no cases of malpositioning, valve migration, embolization, or valve-in-valve. Repositioning was attempted in 10 cases (32.3%). There was one death (3.2%) and one stroke (3.2%) at 30-day follow-up. Mean AV gradient was reduced from 48.7 ± 17.0 mmHg at baseline to 11.8 ± 5.1 mmHg at hospital discharge (P < 0.001); mean effective orifice area (EOA

    Decellularized human lung scaffolds as complex three-dimensional tissue culture models to study functional behavior of fibroblasts.

    No full text
    In vitro culturing of cells in two-dimensional (2D) environments is a widespread used methodology in biomedical research. Most commonly, cells are cultured on artificial plastic dish surfaces, which lead to abnormal functional behaviors, as plastic does not reflect the native microenvironment found in vivo or in situ. Therefore, a multitude of three-dimensional (3D) cell culture systems were developed in the past years, which aim to bridge the gap between 2D cell culture dishes and the in vivo situation. One of the more recent development in the field, the generation of viable precision-cut tissue slices from various organs emerged as an exciting approach to study complex interactions and biological processes ex vivo in 3D. Decellularization of such tissue slices leads to the removal of all functional cells, and leaves behind a scaffold of extracellular matrix (ECM), which closely recapitulates the molecular composition, mechanical properties, topology, and microarchitecture of native ECM. Subsequently, decellularized precision-cut lung slices (PCLS), also called 3D lung tissue culture (3D-LTCs), can be successfully reseeded with a variety of cell types, including fibroblasts, which attach to and engraft into the matrix. Here, we describe the generation of PCLS from resected human lung tissue and their decellularization and recellularization with primary human fibroblasts. This novel 3D tissue culture model allows for various functional studies of fibroblast behavior on native ECM composition and topology

    The instructive extracellular matrix of the lung: Basic composition and alterations in chronic lung disease.

    No full text
    The pulmonary extracellular matrix (ECM) determines the tissue architecture of the lung, and provides mechanical stability and elastic recoil, which are essential for physiological lung function. Biochemical and biomechanical signals initiated by the ECM direct cellular function and differentiation, and thus play a decisive role in lung development, tissue remodelling processes and maintenance of adult homeostasis. Recent proteomic studies have demonstrated that at least 150 different ECM proteins, glycosaminoglycans and modifying enzymes are expressed in the lung, and these assemble into intricate composite biomaterials. These highly insoluble assemblies of interacting ECM proteins and their glycan modifications can act as a solid phase-binding interface for hundreds of secreted proteins, which creates an information-rich signalling template for cell function and differentiation. Dynamic changes within the ECM that occur upon injury or with ageing are associated with several chronic lung diseases. In this review, we summarise the available data about the structure and function of the pulmonary ECM, and highlight changes that occur in idiopathic pulmonary fibrosis (IPF), pulmonary arterial hypertension (PAH), chronic obstructive pulmonary disease (COPD), asthma and lung cancer. We discuss potential mechanisms of ECM remodelling and modification, which we believe are relevant for future diagnosis and treatment of chronic lung disease

    Cardio-anesthesiology considerations for the trans-catheter aortic valve implantation (TAVI) procedure

    No full text
    Transcatheter aortic valve implantation (TAVI) has become the mainstay for highrisk or inoperable patients with symptomatic aortic valve stenosis, and research regarding the use of transcatheter valves in intermediate or low-risk patients is currently ongoing. The aim of this article is to provide comprehensive insight into the anesthetic management of patients undergoing TAVI and to highlight possible gaps in the current knowledge. One important procedural characteristic that is imperative to consider is the type of anesthesia being used and its possible complications. Increasingly, experienced centers have changed from general anesthesia with endotracheal intubation to local anesthesia with sedation, especially when the transfemoral access route is used for TAVI. There is still debate regarding what type of anesthesia should be used in the procedure, and the lack of randomized data makes it even more challenging for the operators © 2016 Hellenic Society of Cardiology
    corecore