158 research outputs found
Holographic renormalization and supersymmetry
Holographic renormalization is a systematic procedure for regulating divergences
in observables in asymptotically locally AdS spacetimes. For dual boundary
field theories which are supersymmetric it is natural to ask whether this defines a
supersymmetric renormalization scheme. Recent results in localization have brought
this question into sharp focus: rigid supersymmetry on a curved boundary requires
specific geometric structures, and general arguments imply that BPS observables,
such as the partition function, are invariant under certain deformations of these
structures. One can then ask if the dual holographic observables are similarly invariant.
We study this question in minimal N = 2 gauged supergravity in four and
five dimensions. In four dimensions we show that holographic renormalization precisely
reproduces the expected field theory results. In five dimensions we find that
no choice of standard holographic counterterms is compatible with supersymmetry,
which leads us to introduce novel finite boundary terms. For a class of solutions satisfying
certain topological assumptions we provide some independent tests of these
new boundary terms, in particular showing that they reproduce the expected VEVs
of conserved charges
MPGD's spatial and energy resolution studies with an adjustable point-like electron source
11th Vienna Conference on Instrumentation (February 2007) , to appear in the Proceedings (NIM A)International audienceMicropattern Gaseous Detectors (MPGD), like Micromegas or GEM, are used or foreseen in particle physics experiments for which a very good spatial resolution is required. We have developed an experimental method to separate the contribution of the transverse diffusion and the multiplication process by varying the number of primary electrons generated by a point-like source. A pulsed nitrogen laser is focused by an optical set-up on the drift electrode which is made of a thin metal layer deposited on a quartz lamina. The number of primary electrons can be adjusted from a few to several thousands on a spot which transverse size is less than RMS. The detector can be positioned with an accuracy of by a motorized three dimensional system. This method was applied to a small Micromegas detector with a gain set between and and an injection of 60 to 2000 photoelectrons. Spatial resolutions as small as were measured with 2000 primary electrons. An estimation of the upper limit of the relative gain variance can be obtained from the measurements
A large dynamic range integrated front-end for photomultiplier tubes
A full custom analog CMOS circuit for obtaining a photomultiplier readout with a 16 bit resolution over 7 V has been developed. It is part of the R&D program for the photomultiplier tube front-end readout of the Pierre Auger Observatory northern site. It performs signal duplication and amplification with three gains: 0.15, 1 and 6. Each amplifier has a resolution of 10 bit and can measure signals with durations of several microseconds with a good baseline stability, for an input charge of up to tens of nano-Coulombs. The amplification is performed by current feedback amplifiers with a bandwidth of 60 MHz.The input impedance, adapted to the coaxial cables, is stable over the whole working range. A prototype was submitted in April 2004 and successfully tested. The linearity over the working range is less than 1%. It was also successfully tested on the Auger surface detector element installed at Orsay (comprised of a Cherenkov water tank equipped with Photonis XP1805 9” diameter photomultiplier tubes). The resolution over 7 V is 16.6 bit.This circuit is the first step towards a “system-on-a-chip” (SoC) solution for a photomultplier tube readout equipped with a fast ADC for signal digitization. A setup using a single cable for both the signal and the photomultiplier high voltage power supply was shown to be successful
Childhood trajectories of inattention, hyperactivity and oppositional behaviors and prediction of substance abuse/dependence: a 15-year longitudinal population-based study.
Numerous prospective studies have shown that children diagnosed with attention deficit/hyperactivity disorder (ADHD) are at higher risk of long-term substance abuse/dependence. However, there are three important limits to these studies: (a) most did not differentiate the role of hyperactivity and inattention; (b) most did not control for associated behavioral problems; and (c) most did not consider females. Our aim was to clarify the unique and interactive contributions of childhood inattention and hyperactivity symptoms to early adulthood substance abuse/dependence. Behavioral problems of 1803 participants (814 males) in a population-based longitudinal study were assessed yearly between 6 and 12 years by mothers and teachers. The prevalence of substance abuse/dependence at age 21 years was 30.7% for nicotine, 13.4% for alcohol, 9.1% for cannabis and 2.0% for cocaine. The significant predictors of nicotine dependence were inattention (odds ratio (OR): 2.25; 95% confidence interval (CI): 1.63-3.11) and opposition (OR: 1.65; 95%: 1.20-2.28). Only opposition contributed to the prediction of cannabis dependence (OR: 2.33; 95% CI: 1.40-3.87) and cocaine dependence (OR: 2.97; 95% CI: 1.06-8.57). The best behavioral predictor of alcohol abuse/dependence (opposition) was only marginally significant (OR: 1.38; 95% CI: 0.98-1.95). Frequent oppositional behaviors during elementary school were clearly the most pervasive predictors of substance abuse/dependence in early adulthood. The association of childhood ADHD with substance abuse/dependence is largely attributable to its association with opposition problems during childhood. However, inattention remained an important predictor of nicotine dependence, in line with genetic and molecular commonalities between the two phenotypes suggested in the literature
SD electronics: simulations on the dynamic range
The surface detector electronics of the Pierre Auger Observatory is characterized by a large dynamic range due to the variation of the signal intensity of the Cherenkov tanks as a function of the distance from the core. In this paper, we present results of simulations and discuss the impact of the dynamic range on the shower reconstruction
Design of the photomultiplier bases for the surface detectors of the Pierre Auger Observatory
The design of the photomultiplier bases for the surface detectors of the Pierre Auger Observatory is presented. The bleeder is purely resistive. The base comprises two outputs: one from the anode and another one from the last dynode followed by an amplifier. The charge ratio between the anode and the amplified dynode is around 30. The design ensures a low consumption (less than 100 mu A at 2 kV), a stability of the gain and of the base line during the whole period of measurement (20 mu s per event) and for the whole dynamic range (max. 1 to 3x10^4 in amplitude). First measurement with a prototype base on the Hamamatsu R5912 photomultiplier tube are presented
A Fixed-Target ExpeRiment at the LHC (AFTER@LHC) : luminosities, target polarisation and a selection of physics studies
We report on a future multi-purpose fixed-target experiment with the proton
or lead ion LHC beams extracted by a bent crystal. The multi-TeV LHC beams
allow for the most energetic fixed-target experiments ever performed. Such an
experiment, tentatively named AFTER for "A Fixed-Target ExperRiment", gives
access to new domains of particle and nuclear physics complementing that of
collider experiments, in particular at RHIC and at the EIC projects. The
instantaneous luminosity at AFTER using typical targets surpasses that of RHIC
by more than 3 orders of magnitude. Beam extraction by a bent crystal offers an
ideal way to obtain a clean and very collimated high-energy beam, without
decreasing the performance of the LHC. The fixed-target mode also has the
advantage of allowing for spin measurements with a polarised target and for an
access over the full backward rapidity domain up to xF ~ - 1. Here, we
elaborate on the reachable luminosities, the target polarisation and a
selection of measurements with hydrogen and deuterium targets.Comment: 6 pages. Proceedings of the Sixth International Conference on Quarks
and Nuclear Physics QNP2012 (16-20 April 2012, Ecole Polytechnique,
Palaiseau,France
Prospectives for A Fixed-Target ExpeRiment at the LHC: AFTER@LHC
We argue that the concept of a multi-purpose fixed-target experiment with the
proton or lead-ion LHC beams extracted by a bent crystal would offer a number
of ground-breaking precision-physics opportunities. The multi-TeV LHC beams
will allow for the most energetic fixed-target experiments ever performed. The
fixed-target mode has the advantage of allowing for high luminosities, spin
measurements with a polarised target, and access over the full backward
rapidity domain --uncharted until now-- up to x_F ~ -1.Comment: 6 pages, 1 table, LaTeX. Proceedings of the 36th International
Conference on High Energy Physics (ICHEP2012), 4-11 July 2012, Melbourne,
Australi
Spin physics at A Fixed-Target ExpeRiment at the LHC (AFTER@LHC)
We outline the opportunities for spin physics which are offered by a next
generation and multi-purpose fixed-target experiment exploiting the proton LHC
beam extracted by a bent crystal. In particular, we focus on the study of
single transverse spin asymetries with the polarisation of the target.Comment: Contributed to the 20th International Spin Physics Symposium,
SPIN2012, 17-22 September 2012, Dubna, Russia, 4 pages, LaTe
- …