364 research outputs found

    Colonoscopy quality assessment in a mass population screening programme based on faecal occult blood test

    Get PDF
    Background and aim: the success of colorectal cancer (CRC) screening programmes largely depends on the quality of the events, processes and outcomes and therefore, quality assurance of endoscopy is an essential component. The quality indicators for colonoscopy in a screening programme setting are different from those performed in symptomatic people. The objective of this study was to report the main quality indicators of colonoscopies performed after a positive faecal occult blood test (FOBT) in a CRC screening programme in Catalonia. Methods: the period of study includes three rounds of the CRC screening programme from June 2006 to July 2013. Two types of FOBT were used: a qualitative biochemical guaiac-based test (gFOBT) and a quantitative immunochemical test (FIT). Quality indicators analysed in this study were compared to recommended colonoscopy standards from the published guidelines. Results: during the study period, 1,806 colonoscopies were performed in 1,691 individuals with a positive FOBT. All indicators were within the standard except waiting time to colonoscopy. Caecal intubation rate was 95.6 % and adequate bowel cleansing 93.6 %. Adenoma detection rate was better using FIT than gFOBT, 30.7 and 3.8 per 1,000 screenees, respectively. Cancer detection rate was also greater using FIT. Nearly 62 % of cancers were diagnosed at an early stage. The overall complication rate was 10.7 . Conclusion: although the majority of results reached the recommended standards, some areas have been identified for quality enhancement. Continuous monitoring of quality indicators is essential for improving the current effectiveness of CRC screening programmes

    Impacto de una intervención informativa sobre el programa de cribado de cáncer colorrectal en profesionales de atención primaria

    Get PDF
    Objetivo: Evaluar el impacto de una intervención informativa a profesionales de atención pri-maria sobre sus conocimientos de cribado de cáncer colorrectal, recomendaciones de vigilanciaposterior y estrategias de derivación. Método diseÑo: Ensayo clínico controlado y aleatorizado por conglomerados. Emplazamiento:centros de atención primaria de L'Hospitalet de Llobregat (Barcelona). Participantes: médi-cos y enfermeras de atención primaria. Intervención: sesión informativa y envío de píldorasinformativas en 6 de 12 centros (seleccionados aleatoriamente) sobre el programa de cribadocáncer colorrectal. Mediciones principales: cuestionario ad hoc que recoge las característicasde los profesionales, los centros y 2 variables contextuales; implicación de los profesionalesen el programa de cribado; conocimientos sobre el cáncer colorrectal, los factores de riesgo,los procedimientos de cribado, las recomendaciones de seguimiento posterior a la exploracióndiagnóstica y las estrategias de derivación. Resultados: La media de la puntuación total en el primer cuestionario fue 8,07(1,38) sobre 11 yla del segundo 8,31(1,39). No se encontraron diferencias estadísticamente significativas entreel grupo intervención y control, sin embargo, en 9 preguntas se aumentó el porcentaje de res-puestas correctas en el grupo intervención, mayoritariamente relacionadas con el seguimientoposterior a la exploración diagnóstica. Conclusiones: La intervención mejora el porcentaje de respuestas correctas, sobre todo enaquellas en las que se obtuvo peor puntuación en el primer cuestionario. Este estudio muestraque los profesionales están familiarizados con el cribado de cáncer colorrectal, pero es impor-tante tener una comunicación frecuente con ellos para mantener actualizada la informaciónrelacionada con el cribado y fomentar su implicación con el mismo

    Wound Healing Modulation through the Local Application of Powder Collagen-Derived Treatments in an Excisional Cutaneous Murine Model

    Get PDF
    15 p.Wound healing includes dynamic processes grouped into three overlapping phases: inflammatory, proliferative, and maturation/remodeling. Collagen is a critical component of a healing wound and, due to its properties, is of great interest in regenerative medicine. This preclinical study was designed to compare the effects of a new collagen-based hydrolysate powder on wound repair to a commercial non-hydrolysate product, in a murine model of cutaneous healing. Circular excisional defects were created on the dorsal skin of Wistar rats (n = 36). Three study groups were established according to the treatment administered. Animals were euthanized after 7 and 18 days. Morphometric and morphological studies were performed to evaluate the healing process. The new collagen treatment led to the smallest open wound area throughout most of the study. After seven days, wound morphometry, contraction, and epithelialization were similar in all groups. Treated animals showed reduced granulation tissue formation and fewer inflammatory cells, and induction of vasculature with respect to untreated animals. After 18 days, animals treated with the new collagen treatment showed accelerated wound closure, significantly increased epithelialization, and more organized repair tissue. Our findings suggest that the new collagen treatment, compared to the untreated control group, produces significantly faster wound closure and, at the same time, promotes a slight progression of the reparative process compared with the rest of the groups.CIBER-BBNViscofan S.A

    New insights into the application of 3D-printing technology in hernia repair.

    Get PDF
    "Publicación presentada para sexenios"Abdominal hernia repair using prosthetic materials is among the surgical interventions most widely performed worldwide. These materials, or meshes, are implanted to close the hernial defect, reinforcing the abdominal muscles and reestablishing mechanical functionality of the wall. Meshes for hernia repair are made of synthetic or biological materials exhibiting multiple shapes and configurations. Despite the myriad of devices currently marketed, the search for the ideal mesh continues as, thus far, no device offers optimal tissue repair and restored mechanical performance while minimizing postoperative complications. Additive manufacturing, or 3D-printing, has great potential for biomedical applications. Over the years, different biomaterials with advanced features have been successfully manufactured via 3D-printing for the repair of hard and soft tissues. This technological improvement is of high clinical relevance and paves the way to produce next-generation devices tailored to suit each individual patient. This review focuses on the state of the art and applications of 3D-printing technology for the manufacture of synthetic meshes. We highlight the latest approaches aimed at developing improved bioactive materials (e.g., optimizing antibacterial performance, drug release, or device opacity for contrast imaging). Challenges, limitations, and future perspectives are discussed, offering a comprehensive scenario for the applicability of 3D-printing in hernia repair.Financial support from the CIBER-BB

    Experimental study on the use of a chlorhexidine-loaded carboxymethylcellulose gel as antibacterial coating for hernia repair meshes

    Get PDF
    21 p.Purpose: Biomaterials with an antimicrobial coating could avoid mesh-associated infection following hernia repair. This study assesses the use of a chlorhexidine-loaded carboxymethylcellulose gel in a model of Staphylococcus aureus mesh infection. Methods: A 1% carboxymethylcellulose gel containing 0.05% chlorhexidine was prepared and tested in vitro and in vivo. The in vitro tests were antibacterial activity (S. aureus; agar diffusion test) and gel cytotoxicity compared to aqueous 0.05% chlorhexidine (fibroblasts; alamarBlue). For the in vivo study, partial abdominal wall defects (5 × 2 cm) were created in New Zealand white rabbits (n = 15) and inoculated with 0.25 mL of S. aureus ( 106 CFU/mL). Defects were repaired with a lightweight polypropylene mesh (Optilene) without coating (n = 3) or coated with a carboxymethylcellulose gel (n = 6) or chlorhexidine-loaded carboxymethylcellulose gel (n = 6). Fourteen days after surgery, bacterial adhesion to the implant (sonication, immunohistochemistry), host tissue incorporation (light microscopy) and macrophage reaction (immunohistochemistry) were examined. Results: Carboxymethylcellulose significantly reduced the toxicity of chlorhexidine (p < 0.001) without limiting its antibacterial activity. While control and gel-coated implants were intensely contaminated, the chlorhexidine-gel-coated meses showed a bacteria-free surface, and only one specimen showed infection signs. The macrophage reaction in this last group was reduced compared to the control (p < 0.05) and gel groups. Conclusions: When incorporated in the carboxymethylcellulose gel, chlorhexidine showed reduced toxicity yet maintained its bactericidal effect at the surgery site. Our findings suggest that this antibacterial gel-coated polypropylene meshes for hernia repair prevent bacterial adhesion to the mesh surface and have no detrimental effects on wound repair.Ministerio de Ciencia, Innovación y Universidade

    Colorectal cancer screening programme in Spain: results of key performance indicators after five rounds (2000-2012)

    Get PDF
    A l'article en PDF consta com a vol. 5Effective quality assurance is essential in any screening programme. This article provides a unique insight into key quality indicators of five rounds of the first population-based colorectal cancer screening programme implemented in Spain (2000-2012), providing the results according to the type of screening (prevalent or first screen and incident or subsequent screen) and test (guaiac or immunochemical). The total crude participation rate increased from 17.2% (11,011) in the first round to 35.9% (22,988) in the last one. Rescreening rate was very high (88.6% in the fifth round). Positivity rate was superior with the faecal immunochemical test (6.2%) than with the guaiac-based test (0.7%) (p< 0.0001) and detection rates were also better with the immunochemical test. The most significant rise in detection rate was observed for high risk adenoma in men (45.5 per 1,000 screened). Most cancers were diagnosed at an early stage (61.4%) and there was a statistically significant difference between those detected in first or subsequent screening (52.6% and 70.0% respectively; p= 0.024). The availability of these results substantially improves data comparisons and the exchange of experience between screening programmes
    corecore