9 research outputs found

    Sensitization to isothiazolinones in the Spanish Contact Dermatitis Registry (REIDAC): 2019–2021 epidemiological situation

    Get PDF
    Background: Current frequency and risk factors for sensitization to methylisothiazolinone (MI), methylchloroisothiazolinone/methylisothiazolinone (MCI/MI), benzisothiazolinone (BIT) and octylisothiazolinone (OIT) in Spain are not well known. Objectives: To study the frequency of sensitization, risk factors and simultaneous sensitization between the four isothiazolinones. Materials and Methods: We analysed all 2019-2021 consecutive patients patch-tested with MI (0.2% aq.), MCI/MI (0.02% aq.), BIT (0.1% pet.) and OIT (0.1% pet) within the Spanish Contact Dermatitis Registry (REIDAC). Results: A total of 2511 patients were analysed. Frequencies of sensitization were: any isothiazolinone 15.7%, MI 6.8%, MCI/MI 4.8%, BIT 3.5% and OIT 0.5%. MI and MCI/MI sensitization was associated with being occupationally active, hand dermatitis, detergents and age over 40. BIT sensitization was associated with leg dermatitis and age over 40. About one in nine MI-positive patients were positive to BIT, whereas one in five BIT-positive patients were positive to MI. Conclusions: Sensitization to MI, MCI/MI and BIT is still common in Spain, while sensitization to OIT is rare. Currently, sensitization to MI and MCI/MI seems to be occupationally related. Although its origin is unknown, sensitization to BIT is more frequent in patients aged over 40 years. Simultaneous sensitization between MI and BIT is uncommon.The Spanish Registry of Contact Dermatitis (REIDAC) is promoted by the Fundación Piel Sana (Academia Española de Dermatología y Venereología), which has received financial support from the Spanish Medicines and Health Products Agency (Agencia Española de Medicamentos y Productos Sanitarios. https://www.boe.es/boe/dias/2022/04/11/pdfs/BOE-A-2022-5975.pdf) and Sanofi. The funders were not involved in the design and conduct of the study, collection, management, analysis and interpretation of data, preparation, review, approval of the manuscript, or decision to submit the manuscript for publication

    Patch testing during the COVID-19 pandemic: recommendations of the AEDV's Spanish Contact Dermatitis and Skin Allergy Research Group (GEIDAC)

    No full text
    Con el progresivo control de la pandemia por SARS-CoV-2, los miembros del Grupo Español de Investigación en Dermatitis de Contacto y Alergia Cutánea (GEIDAC) realizan una propuesta sobre cuáles van a ser los requisitos, las limitaciones y los condicionantes para reanudar el servicio en las unidades de dermatitis de contacto en un escenario en el que se presume la persistencia del virus, con episodios ocasionales o estacionales de exacerbación. Se aconseja ajustar el número de pruebas epicutáneas (PE) a las posibilidades de cada centro y la revisión de los casos en lista de espera para priorizar a los pacientes en función de la gravedad y la urgencia. Se ofrecerán, si es factible, métodos telemáticos para los documentos relativos a las PE (información, pautas, documentos de consentimiento informado). De estar disponible, puede ofrecerse la opción de realizar una primera visita telemática. Igualmente, en pacientes seleccionados puede llevarse a cabo una televisita en las visitas de lectura a través de imágenes realizadas por el paciente o mediante una videovisita que permita visualizar el resultado de la exploración. Estas acciones permitirán reducir el número de visitas presenciales, aunque no el tiempo dedicado y asignado al facultativo para los actos médicos. Todas estas recomendaciones son sugerencias y se adaptarán a los requisitos y a las posibilidades de cada centro sanitario

    Contact dermatitis from glucose sensors in Spain: A multicentric approach

    No full text
    Background: Allergic contact dermatitis from glucose sensors may interfere with their ongoing application. Objective: To evaluate a series of Spanish patients with contact dermatitis to glucose sensors regarding former sources of contact allergens, patch test results, and outcomes from the ongoing use of the device. Methods: A series of patients with contact dermatitis from glucose sensors was investigated in eight dermatology departments across Spain (epidemiological features, brands, latency time to develop dermatitis, the ability to continue using the devices as well as the patch test results). Results: Thirty patients were evaluated (mean age 20.9 years). A total of 66.7% were children and 66.7% female. Ninety per cent used Freestyle Libre (FSL). Eight of 26 (30.8%) reacted to isobornyl acrylate (IBOA) and two of 20 (10.0%) to N,N dimethylacrylamide (DMAA). The mean latency time to develop dermatitis was 9 months. Sixteen of 29 (55.2%) patients continued using the same sensor causing the reaction. Thirteen of 29 (44.8%) patients were unable to continue using the sensor because of severe reactions. Of these, five were positive to IBOA, one to IBOA and DMAA, one to DMAA, one to colophony, and one to isopropyl alcohol wipes. In one patient, the outcome was unknown. Conclusion: The frequency of sensitisation to IBOA and DMAA, was lower than in other European series, but similar to a previously published Spanish article. Legislation requiring manufacturers to provide information regarding the composition of medical devices and cooperate with the investigations into contact dermatitis is urgently needed

    Outbreak of occupational allergic contact dermatitis from a smartphone screen protector glue

    No full text
    Background: Sensitization to acrylates is a concern in the occupational/environmental dermatology field. Objective: To describe an occupational allergic contact dermatitis (ACD) outbreak from a smartphone screen protector glue. Methods: Thirteen affected workers of a chain store selling phone screen protectors were investigated in five Spanish dermatology departments. The glue datasheet and label were assessed. A chemical analysis of the glue was performed. Based on this, some patients underwent additional testing. Results: All patients (all female, mean age: 25) had severe fingertip dermatitis. The datasheet/label indicated that the glue contained isobornyl acrylate (IBOA), a “photoinitiator” and polyurethane oligomer. The company informed us that the ingredients were polyurethane acrylate, “methacrylate” (unspecified), acrylic acid, hydroxyethyl methacrylate, propylmethoxy siloxane, and photoinitiator 184. Isobornyl acrylate (or IBOA) and N,N-dimethylacrylamide (DMAA) were patch tested in eight and two cases, respectively, with negative results. A chemical analysis revealed 4-acryloylmorpholine (ACMO); isobornyl methacrylate (IBMA), and lauryl acrylate in one glue sample. Seven patients were patch tested with dilutions of the identified substances and six of seven were positive for ACMO 0.5% pet. Conclusion: An outbreak of occupational ACD, likely from ACMO in a glue is described. Further investigations are needed to corroborate the role played by each compound identified in the chemical analyses

    Nonoccupational Allergic Contact Dermatitis to 4-Acryloylmorpholine in Smartwatch Screen Protectors Glue

    No full text
    Background We recently identified an outbreak of occupational allergic contact dermatitis (ACD) involving workers of a Spanish company selling smartphone protective cases from a glue product. A chemical analysis of one glue sample revealed the presence of 4-acryloylmorpholine among other allergens. The same glue is also used to attach tempered glass protective cases to Apple smartwatches. Objective Our objective was to describe a case series of nonoccupational consumer ACD from the previously mentioned Apple smartwatch protective case glue. Methods We evaluated epidemiological and clinical data, as well as patch tests results. Results Three women were diagnosed with nonoccupational ACD from the adhesive. An annular vesicular inflammatory plaque involving the dorsal aspect of the wrist was initially observed in all. Two of the 3 patients were patch tested with 4-acryloylmorpholine 0.5% with positive strong reactions. Both also strongly reacted to a sample of the glue semiopen tested in a drop of petrolatum. One of them was also positive for various acrylates. Conclusions 4-Acryloylmorpholine has been identified in an adhesive used to attach protective cases to smartwatches. Nonoccupational ACD have been described to involve consumers of smartwatches. A UV-curable adhesive used to attach protective cases to smartwatches has been considered to be the culprit

    Erratum to: Guidelines for the use and interpretation of assays for monitoring autophagy (3rd edition) (Autophagy, 12, 1, 1-222, 10.1080/15548627.2015.1100356

    No full text
    non present
    corecore