1,213 research outputs found

    Measurements of vacuum magnetic birefringence using permanent dipole magnets: the PVLAS experiment

    Get PDF
    The PVLAS collaboration is presently assembling a new apparatus (at the INFN section of Ferrara, Italy) to detect vacuum magnetic birefringence (VMB). VMB is related to the structure of the QED vacuum and is predicted by the Euler-Heisenberg-Weisskopf effective Lagrangian. It can be detected by measuring the ellipticity acquired by a linearly polarised light beam propagating through a strong magnetic field. Using the very same optical technique it is also possible to search for hypothetical low-mass particles interacting with two photons, such as axion-like (ALP) or millicharged particles (MCP). Here we report results of a scaled-down test setup and describe the new PVLAS apparatus. This latter one is in construction and is based on a high-sensitivity ellipsometer with a high-finesse Fabry-Perot cavity (>4×105>4\times 10^5) and two 0.8 m long 2.5 T rotating permanent dipole magnets. Measurements with the test setup have improved by a factor 2 the previous upper bound on the parameter AeA_e, which determines the strength of the nonlinear terms in the QED Lagrangian: Ae(PVLAS)<3.3×10−21A_e^{\rm (PVLAS)} < 3.3 \times 10^{-21} T−2^{-2} 95% c.l. Furthermore, new laboratory limits have been put on the inverse coupling constant of ALPs to two photons and confirmation of previous limits on the fractional charge of millicharged particles is given

    The PVLAS experiment: measuring vacuum magnetic birefringence and dichroism with a birefringent Fabry-Perot cavity

    Get PDF
    Vacuum magnetic birefringence was predicted long time ago and is still lacking a direct experimental confirmation. Several experimental efforts are striving to reach this goal, and the sequence of results promises a success in the next few years. This measurement generally is accompanied by the search for hypothetical light particles that couple to two photons. The PVLAS experiment employs a sensitive polarimeter based on a high finesse Fabry-Perot cavity. In this paper we report on the latest experimental results of this experiment. The data are analysed taking into account the intrinsic birefringence of the dielectric mirrors of the cavity. Besides the limit on the vacuum magnetic birefringence, the measurements also allow the model-independent exclusion of new regions in the parameter space of axion-like and milli-charged particles. In particular, these last limits hold also for all types of neutrinos, resulting in a laboratory limit on their charge

    First results from the new PVLAS apparatus: a new limit on vacuum magnetic birefringence

    Full text link
    Several groups are carrying out experiments to observe and measure vacuum magnetic birefringence, predicted by Quantum Electrodynamics (QED). We have started running the new PVLAS apparatus installed in Ferrara, Italy, and have measured a noise floor value for the unitary field magnetic birefringence of vacuum Δnu(vac)=(4±20)×10−23\Delta n_u^{\rm (vac)}= (4\pm 20) \times 10^{-23} T−2^{-2} (the error represents a 1σ\sigma deviation). This measurement is compatible with zero and hence represents a new limit on vacuum magnetic birefringence deriving from non linear electrodynamics. This result reduces to a factor 50 the gap to be overcome to measure for the first time the value of Δnu(vac,QED)\Delta n_u^{\rm (vac,QED)} predicted by QED: Δnu(vac,QED)=4×10−24\Delta n_u^{\rm (vac,QED)}= 4\times 10^{-24} ~T−2^{-2}. These birefringence measurements also yield improved model-independent bounds on the coupling constant of axion-like particles to two photons, for masses greater than 1 meV, along with a factor two improvement of the fractional charge limit on millicharged particles (fermions and scalars), including neutrinos

    New PVLAS model independent limit for the axion coupling to γγ\gamma\gamma for axion masses above 1meV

    Full text link
    During 2014 the PVLAS experiment has started data taking with a new apparatus installed at the INFN Section of Ferrara, Italy. The main target of the experiment is the observation of magnetic birefringence of vacuum. According to QED, the ellipticity generated by the magnetic birefringence of vacuum in the experimental apparatus is expected to be ψ(QED)≈5×10−11\psi^{\rm(QED)} \approx 5\times10^{-11}. No ellipticity signal is present so far with a noise floor ψ(noise)≈2.5×10−9\psi^{\rm(noise)} \approx 2.5\times10^{-9} after 210 hours of data taking. The resulting ellipticity limit provides the best model independent upper limit on the coupling of axions to γγ\gamma\gamma for axion masses above 10−310^{-3}eV

    Measurement of the Cotton Mouton effect of water vapour

    Full text link
    In this paper we report on a measurement of the Cotton Mouton effect of water vapour. Measurement performed at room temperature (T=301T=301 K) with a wavelength of 1064 nm gave the value Δnu=(6.67±0.45)⋅10−15\Delta n_u = (6.67 \pm 0.45) \cdot 10^{-15} for the unit magnetic birefringence (1 T magnetic field and atmospheric pressure)

    Experimental observation of optical rotation generated in vacuum by a magnetic field

    Get PDF
    We report the experimental observation of a light polarization rotation in vacuum in the presence of a transverse magnetic field. Assuming that data distribution is Gaussian, the average measured rotation is (3.9+/-0.5)e-12 rad/pass, at 5 T with 44000 passes through a 1m long magnet, with lambda = 1064 nm. The relevance of this result in terms of the existence of a light, neutral, spin-zero particle is discussed.Comment: 11 pages, 4 figures, submitted to Physical Review Letters Comment to version 2: minor changes to abstract and final discussion. Added 2 references Comment to version 3: corrected minor typographical errors, eliminated the distinction between scalar and pseudoscalar in the particle interpretation of the resul

    Towards a direct measurement of vacuum magnetic birefringence: PVLAS achievements

    Full text link
    Nonlinear effects in vacuum have been predicted but never observed yet directly. The PVLAS collaboration has long been working on an apparatus aimed at detecting such effects by measuring vacuum magnetic birefringence. Unfortunately the sensitivity has been affected by unaccounted noise and systematics since the beginning. A new small prototype ellipsometer has been designed and characterized at the Department of Physics of the University of Ferrara, Italy entirely mounted on a single seismically isolated optical bench. With a finesse F = 414000 and a cavity length L = 0.5 m we have reached the predicted sensitivity of psi = 2x10^-8 1/sqrt(Hz) given the laser power at the output of the ellipsomenter of P = 24 mW. This record result demonstrates the feasibility of reaching such sensitivities and opens the way to designing a dedicated apparatus for a first detection of vacuum magnetic birefringence

    Gluten contamination of canned and dry grain-free commercial pet foods determined by HPLC-HRMS

    Get PDF
    The aim was to determine the absence of gluten in pet food samples marked as ‘grain-free’ and ‘gluten-free’ diets, to assess the reliability of manufacturer labelling of such products. A total of 15 diets labelled as grain- or gluten-free and 2 commercial diets containing wheat were sampled. An analytical procedure using high-pressure liquid chromatography coupled with mass spectrometry with high power of resolution was developed and applied to determine specific markers of wheat gluten. The results are expressed as mg of wheat flour type ‘00’ present in 1 g of feed. The quantification limit (LOQ) obtained in the flour for ion m/z 894.5043, z = 2, is 4 mg of flour per gram. In 14 out of the 15 samples from a grain- or gluten-free diet the quantifier ion signal was < LOQ, while in 1 out of the 15 samples 10 mg of flour/g feed were measured.Highlights Adverse reaction to gluten in dogs have been documented in certain breeds Gluten is tricky to detect and measure in pet food Contamination of gluten in pet food samples marked as ‘grain-free’ and ‘gluten-free’ diets An analytical procedure was developed using HPLC coupled with HRM
    • …
    corecore