6,625 research outputs found

    Heat pipes for wing leading edges of hypersonic vehicles

    Get PDF
    Wing leading edge heat pipes were conceptually designed for three types of vehicle: an entry research vehicle, aero-space plane, and advanced shuttle. A full scale, internally instrumented sodium/Hastelloy X heat pipe was successfully designed and fabricated for the advanced shuttle application. The 69.4 inch long heat pipe reduces peak leading edge temperatures from 3500 F to 1800 F. It is internally instrumented with thermocouples and pressure transducers to measure sodium vapor qualities. Large thermal gradients and consequently large thermal stresses, which have the potential of limiting heat pipe life, were predicted to occur during startup. A test stand and test plan were developed for subsequent testing of this heat pipe. Heat pipe manufacturing technology was advanced during this program, including the development of an innovative technique for wick installation

    Conductivity in Jurkat cell suspension after ultrashort electric pulsing

    No full text
    Ultrashort electric pulses applied to similar cell lines such as Jurkat and HL-60 cells can produce markedly different results , which have been documented extensively over the last few years. We now report changes in electrical conductivity of Jurkat cells subjected to traditional electroporation pulses (50 ms pulse length) and ultrashort pulses (10 ns pulse length) using time domain dielectric spectroscopy (TDS). A single 10 ns, 150 kV/cm pulse did not noticeably alter suspension conductivity while a 50 ms, 2.12 kV/cm pulse with the same energy caused an appreciable conductivity rise. These results support the hypothesis that electroporation pulses primarily interact with the cell membrane and cause conductivity rises due to ion transport from the cell to the external media, while pulses with nanosecond duration primarily interact with the membranes of intracellular organelles. However, multiple ultrashort pulses have a cumulative effect on the plasma membrane, with five pulses causing a gradual rise in conductivity up to ten minutes post-pulsing

    Revealing design complexity: Lessons from the Open University

    Get PDF
    Design is an inherently complex activity. Design thinking is cognitively complex and design practice is contextually complex. This has implications for university-level design education which has traditionally displayed clear distinctions between the full-time and part-time undergraduate sectors, particularly in their teaching and learning strategies. However, a number of pressures and trends are evident which suggest that these two sectors are moving closer together. One of the drivers in this phenomenon is the need for students to be exposed to realistic levels of design complexity. This paper examines complexity in design and draws some significant parallels between modern design practice in general and the production of a new undergraduate course at the Open University. Both are used to illuminate design complexity. The paper suggests that some of the tools, techniques and approaches of part-time, undergraduate, distance design education might usefully be exploited in more traditional, full-time course models

    Permutation combinatorics of worldsheet moduli space

    Get PDF
    52 pages, 21 figures52 pages, 21 figures; minor corrections, "On the" dropped from title, matches published version52 pages, 21 figures; minor corrections, "On the" dropped from title, matches published versio

    S-, P- and D-wave resonances in positronium-sodium and positronium-potassium scattering

    Get PDF
    Scattering of positronium (Ps) by sodium and potassium atoms has been investigated employing a three-Ps-state coupled-channel model with Ps(1s,2s,2p) states using a time-reversal-symmetric regularized electron-exchange model potential fitted to reproduce accurate theoretical results for PsNa and PsK binding energies. We find a narrow S-wave singlet resonance at 4.58 eV of width 0.002 eV in the Ps-Na system and at 4.77 eV of width 0.003 eV in the Ps-K system. Singlet P-wave resonances in both systems are found at 5.07 eV of width 0.3 eV. Singlet D-wave structures are found at 5.3 eV in both systems. We also report results for elastic and Ps-excitation cross sections for Ps scattering by Na and K.Comment: 9 pages, 5 figures, Accepted in Journal of Physics

    Nanosecond electric pulses penetrate the nucleus and enhance speckle formation

    No full text
    Nanosecond electric pulses generate nanopores in the interior membranes of cells and modulate cellular functions. Here, we used confocal microscopy and flow cytometry to observe Smith antigen antibody (Y12) binding to nuclear speckles, known as small nuclear ribonucleoprotein particles (snRNPs) or intrachromatin granule clusters (IGCs), in Jurkat cells following one or five 10 ns, 150 kV/cm pulses. Using confocal microscopy and flow cytometry, we observed changes in nuclear speckle labeling that suggested a disruption of pre-messenger RNA splicing mechanisms. Pulse exposure increased the nuclear speckled substructures by 2.5-fold above basal levels while the propidium iodide (PI) uptake in pulsed cells was unchanged. The resulting nuclear speckle changes were also cell cycle dependent. These findings suggest that 10 ns pulses directly influenced nuclear processes, such as the changes in the nuclear RNA–protein complexes

    Electron Trajectories and Critical Current in a Two-Dimensional Planar Magnetically Insulated Crossed-Field Gap

    Get PDF
    The critical current in a one-dimensional (1D) crossed-field gap is defined by the transition from a cycloidal flow to a near-Brillouin (nB) state characterized by electron flow orthogonal to both the electric and magnetic fields and uniform virtual cathode formation. Motivated by recent studies on space-charge-limited current in non-magnetic diodes, we assess the meaning of critical current in a magentically insulated two-dimensional (2D) planar crossed-field geometry. Particle-in-cell (PIC) simulations demonstrate that binary behavior between a laminar and turbulent state does not occur in 2D because the virtual cathode is nonuniform. Rather than a distinct nB state above the critical current as in 1D, there is an increase in Brillouin contribution with the presence of cycloidal components and noise even at low currents. To evaluate the electron flows in a 2D crossed-field gap in the absence of a binary transition, we developed two metrics to assess the Brillouin and cycloidal components in a 2D planar crossed-field gap for various emission widths and injection current densities by comparing the phase space plots from PIC simulations to analytical solutions for cycloidal and Brillouin flow. For a smaller emission width, less Brillouin contribution occurs for a given injection current, while maximizing the cycloidal noise requires a larger injection current. Once the virtual cathode starts to form and expand with increasing injection current, the cycloidal noise reaches its peak and then decreases while the Brillouin components become significant and increase

    Resilience-Focused HIV Care to Promote Psychological Well-Being During COVID-19 and Other Catastrophes

    Get PDF
    The COVID-19 pandemic has adversely affected people with HIV due to disruptions in prevention and care services, economic impacts, and social isolation. These stressors have contributed to worse physical health, HIV treatment outcomes, and psychological wellness. Psychological sequelae associated with COVID-19 threaten the overall well-being of people with HIV and efforts to end the HIV epidemic. Resilience is a known mediator of health disparities and can improve psychological wellness and behavioral health outcomes along the HIV Continuum of Care. Though resilience is often organically developed in individuals as a result of overcoming adversity, it may be fostered through multi-level internal and external resourcing (at psychological, interpersonal, spiritual, and community/neighborhood levels). In this Perspective, resilience-focused HIV care is defined as a model of care in which providers promote optimum health for people with HIV by facilitating multi-level resourcing to buffer the effects of adversity and foster well-being. Adoption of resilience-focused HIV care may help providers better promote well-being among people living with HIV during this time of increased psychological stress and help prepare systems of care for future catastrophes. Informed by the literature, we constructed a set of core principles and considerations for successful adoption and sustainability of resilience-focused HIV care. Our definition of resilience-focused HIV care marks a novel contribution to the knowledge base and responds to the call for a multidimensional definition of resilience as part of HIV research

    Modeling of mode-locking in a laser with spatially separate gain media

    Get PDF
    We present a novel laser mode-locking scheme and discuss its unusual properties and feasibility using a theoretical model. A large set of single-frequency continuous-wave lasers oscillate by amplification in spatially separated gain media. They are mutually phase-locked by nonlinear feedback from a common saturable absorber. As a result, ultra short pulses are generated. The new scheme offers three significant benefits: the light that is amplified in each medium is continuous wave, thereby avoiding issues related to group velocity dispersion and nonlinear effects that can perturb the pulse shape. The set of frequencies on which the laser oscillates, and therefore the pulse repetition rate, is controlled by the geometry of resonator-internal optical elements, not by the cavity length. Finally, the bandwidth of the laser can be controlled by switching gain modules on and off. This scheme offers a route to mode-locked lasers with high average output power, repetition rates that can be scaled into the THz range, and a bandwidth that can be dynamically controlled. The approach is particularly suited for implementation using semiconductor diode laser arrays.Comment: 13 pages, 5 figures, submitted to Optics Expres
    • …
    corecore