17 research outputs found
The impact of surgical delay on resectability of colorectal cancer: An international prospective cohort study
AIM: The SARS-CoV-2 pandemic has provided a unique opportunity to explore the impact of surgical delays on cancer resectability. This study aimed to compare resectability for colorectal cancer patients undergoing delayed versus non-delayed surgery. METHODS: This was an international prospective cohort study of consecutive colorectal cancer patients with a decision for curative surgery (January-April 2020). Surgical delay was defined as an operation taking place more than 4 weeks after treatment decision, in a patient who did not receive neoadjuvant therapy. A subgroup analysis explored the effects of delay in elective patients only. The impact of longer delays was explored in a sensitivity analysis. The primary outcome was complete resection, defined as curative resection with an R0 margin. RESULTS: Overall, 5453 patients from 304 hospitals in 47 countries were included, of whom 6.6% (358/5453) did not receive their planned operation. Of the 4304 operated patients without neoadjuvant therapy, 40.5% (1744/4304) were delayed beyond 4 weeks. Delayed patients were more likely to be older, men, more comorbid, have higher body mass index and have rectal cancer and early stage disease. Delayed patients had higher unadjusted rates of complete resection (93.7% vs. 91.9%, P = 0.032) and lower rates of emergency surgery (4.5% vs. 22.5%, P < 0.001). After adjustment, delay was not associated with a lower rate of complete resection (OR 1.18, 95% CI 0.90-1.55, P = 0.224), which was consistent in elective patients only (OR 0.94, 95% CI 0.69-1.27, P = 0.672). Longer delays were not associated with poorer outcomes. CONCLUSION: One in 15 colorectal cancer patients did not receive their planned operation during the first wave of COVID-19. Surgical delay did not appear to compromise resectability, raising the hypothesis that any reduction in long-term survival attributable to delays is likely to be due to micro-metastatic disease
Impaction allografting for massive femoral defects in revision hip arthroplasty using collared textured stems.
We present a prospective study of impaction grafting using collared textured stems in femurs with massive defects (defined as requiring \u3e150 cm(3) of cancellous allograft). Eighteen hips were followed for a minimum of 2 years. Average Harris hip scores increased from 50 preoperatively to 83 at most recent follow-up. Seventeen hips were functioning well at the time of most recent follow-up and exhibited no stem subsidence or aseptic loosening. One hip was associated with visible subsidence and required further revision. Single-photon emission computed tomography analyses performed at an average of 37 months indicated active graft reorganization in all cases studied. Impaction allografting with collared textured stems for massive defects demonstrates good intermediate-term clinical results and may be a useful alternative to allograft stem composites and megaprostheses
Hemoglobin substitutes.
Orthopaedic patients frequently require blood transfusions to treat peri-operative anemia. Research in the area of hemoglobin substitutes has been of great interest since it holds the promise of reducing the reliance on allogeneic blood transfusions. The three categories of hemoglobin substitutes are (1) cell-free, extracellular hemoglobin preparations made from human or bovine hemoglobin (hemoglobin-based oxygen carriers or HBOCs); (2) fluorine-substituted linear or cyclic carbon chains with a high oxygen-carrying capacity (perfluorocarbons); and (3) liposome-encapsulated hemoglobin. Of the three, HBOCs have been the most extensively studied and tested in preclinical and clinical trials that have shown success in diminishing the number of blood transfusions as well as an overall favorable side-effect profile. This has been demonstrated in vascular, cardiothoracic, and orthopaedic patients. HBOC-201, which is a preparation of cell-free bovine hemoglobin, has been approved for clinical use in South Africa. These products may well become an important tool for physicians treating peri-operative anemia in orthopaedic patients
A Review of Ceramic Bearing Materials in Total Joint Arthroplasty
Bearings made of ceramics have ultra-low wear properties that make them suitable for total hip arthroplasty (THA) and total knee arthroplasty (TKA). when compared to cobalt chrome (CoCr)-on-polyethylene (PE) articulations, ceramics offer drastic reductions in bearing wear rates. Lower wear rates result in fewer wear particles produced by the articulating surfaces. in theory, this should reduce the risk of periprosthetic osteolysis and premature implant loosening, thereby contributing to the longevity of total joints. in addition to ceramics, other alternative bearing couples, such as highly cross-linked PE (XLPE) and metal-on-metal also offer less wear than CoCr-on-PE articulations in total joint arthroplasty. Alumina and zirconia ceramics are familiar to orthopaedic surgeons since both materials have been used in total joints for several decades. While not new in Europe, alumina-on-alumina ceramic total hips have only recently become available for widespread use in the United States from various orthopaedic implant manufacturers. as the search for the ideal total joint bearing material continues, composite materials of existing ceramics, metal-on-ceramic articulations, and new ceramic technologies will offer more choices to the arthroplasty surgeon. the objective of this paper is to present an overview of material properties, clinical applications, evolution, and limitations of ceramic materials that are of interest to the arthroplasty surgeon
Ceramic-on-ceramic total hip arthroplasty in patients younger than 55 years.
PURPOSE: To review the outcomes of 65 patients younger than 55 years who underwent uncemented total hip arthroplasty (THA) using third-generation ceramic-on-ceramic prostheses.
METHODS: Medical records of 30 men and 35 women (80 hips) aged 18 to 55 (mean, 39) years who underwent uncemented THA using third-generation ceramic-onceramic prostheses by a single surgeon were reviewed. 61 THAs used the Reflection cup with the Synergy stem (n=49), Spectron stem (n=7), or Anthology stem (n=5), and 19 THAs used the Trident cup with the Secur-Fit stem. Outcomes were assessed based on the UCLA Activity Score and Harris Hip Score, as well as radiolucency around the implants, malposition, and subsidence on radiographs. Patients were asked about their satisfaction with current activity level (yes/no), activity limitation (no limitation, musculoskeletal limitation, psychological impediments and lack of motivation, and pain or disability of the operative hip), and change in occupational activity level (same or similar, more active, and less active or disability).
RESULTS: The mean follow-up period was 54 (range, 24-110) months. Six patients were excluded from the analysis owing to prosthetic failure secondary to ceramic liner fracture after falling (n=2), acetabular component loosening (n=1), intolerable squeak (n=1), periprosthetic fracture (n=1), and instability (n=1). The mean UCLA Activity Score improved from 4.0 (range, 1-10) to 7.7 (range, 2-10) [p
CONCLUSION: Ceramic-on-ceramic THA achieved acceptable clinical and radiographic outcomes
Ceramic-on-Ceramic Total Hip Arthroplasty in Patients Younger Than 55 Years
PURPOSE: To review the outcomes of 65 patients younger than 55 years who underwent uncemented total hip arthroplasty (THA) using third-generation ceramic-on-ceramic prostheses.
METHODS: Medical records of 30 men and 35 women (80 hips) aged 18 to 55 (mean, 39) years who underwent uncemented THA using third-generation ceramic-onceramic prostheses by a single surgeon were reviewed. 61 THAs used the Reflection cup with the Synergy stem (n=49), Spectron stem (n=7), or Anthology stem (n=5), and 19 THAs used the Trident cup with the Secur-Fit stem. Outcomes were assessed based on the UCLA Activity Score and Harris Hip Score, as well as radiolucency around the implants, malposition, and subsidence on radiographs. Patients were asked about their satisfaction with current activity level (yes/no), activity limitation (no limitation, musculoskeletal limitation, psychological impediments and lack of motivation, and pain or disability of the operative hip), and change in occupational activity level (same or similar, more active, and less active or disability).
RESULTS: The mean follow-up period was 54 (range, 24-110) months. Six patients were excluded from the analysis owing to prosthetic failure secondary to ceramic liner fracture after falling (n=2), acetabular component loosening (n=1), intolerable squeak (n=1), periprosthetic fracture (n=1), and instability (n=1). The mean UCLA Activity Score improved from 4.0 (range, 1-10) to 7.7 (range, 2-10) [p
CONCLUSION: Ceramic-on-ceramic THA achieved acceptable clinical and radiographic outcomes