51 research outputs found

    Ventilatory settings in the initial 72 h and their association with outcome in out-of-hospital cardiac arrest patients: a preplanned secondary analysis of the targeted hypothermia versus targeted normothermia after out-of-hospital cardiac arrest (TTM2) trial

    Full text link
    Purpose: The optimal ventilatory settings in patients after cardiac arrest and their association with outcome remain unclear. The aim of this study was to describe the ventilatory settings applied in the first 72 h of mechanical ventilation in patients after out-of-hospital cardiac arrest and their association with 6-month outcomes. Methods: Preplanned sub-analysis of the Target Temperature Management-2 trial. Clinical outcomes were mortality and functional status (assessed by the Modified Rankin Scale) 6 months after randomization. Results: A total of 1848 patients were included (mean age 64 [Standard Deviation, SD = 14] years). At 6 months, 950 (51%) patients were alive and 898 (49%) were dead. Median tidal volume (VT) was 7 (Interquartile range, IQR = 6.2-8.5) mL per Predicted Body Weight (PBW), positive end expiratory pressure (PEEP) was 7 (IQR = 5-9) cmH20, plateau pressure was 20 cmH20 (IQR = 17-23), driving pressure was 12 cmH20 (IQR = 10-15), mechanical power 16.2 J/min (IQR = 12.1-21.8), ventilatory ratio was 1.27 (IQR = 1.04-1.6), and respiratory rate was 17 breaths/minute (IQR = 14-20). Median partial pressure of oxygen was 87 mmHg (IQR = 75-105), and partial pressure of carbon dioxide was 40.5 mmHg (IQR = 36-45.7). Respiratory rate, driving pressure, and mechanical power were independently associated with 6-month mortality (omnibus p-values for their non-linear trajectories: p < 0.0001, p = 0.026, and p = 0.029, respectively). Respiratory rate and driving pressure were also independently associated with poor neurological outcome (odds ratio, OR = 1.035, 95% confidence interval, CI = 1.003-1.068, p = 0.030, and OR = 1.005, 95% CI = 1.001-1.036, p = 0.048). A composite formula calculated as [(4*driving pressure) + respiratory rate] was independently associated with mortality and poor neurological outcome. Conclusions: Protective ventilation strategies are commonly applied in patients after cardiac arrest. Ventilator settings in the first 72 h after hospital admission, in particular driving pressure and respiratory rate, may influence 6-month outcomes

    Probabilistic analysis of COVID-19 patients' individual length of stay in Swiss intensive care units

    Full text link
    RATIONALE The COVID-19 pandemic induces considerable strain on intensive care unit resources. OBJECTIVES We aim to provide early predictions of individual patients' intensive care unit length of stay, which might improve resource allocation and patient care during the on-going pandemic. METHODS We developed a new semiparametric distributional index model depending on covariates which are available within 24h after intensive care unit admission. The model was trained on a large cohort of acute respiratory distress syndrome patients out of the Minimal Dataset of the Swiss Society of Intensive Care Medicine. Then, we predict individual length of stay of patients in the RISC-19-ICU registry. MEASUREMENTS The RISC-19-ICU Investigators for Switzerland collected data of 557 critically ill patients with COVID-19. MAIN RESULTS The model gives probabilistically and marginally calibrated predictions which are more informative than the empirical length of stay distribution of the training data. However, marginal calibration was worse after approximately 20 days in the whole cohort and in different subgroups. Long staying COVID-19 patients have shorter length of stay than regular acute respiratory distress syndrome patients. We found differences in LoS with respect to age categories and gender but not in regions of Switzerland with different stress of intensive care unit resources. CONCLUSION A new probabilistic model permits calibrated and informative probabilistic prediction of LoS of individual patients with COVID-19. Long staying patients could be discovered early. The model may be the basis to simulate stochastic models for bed occupation in intensive care units under different casemix scenarios

    The importance of post marketing quality control

    Full text link
    BACKGROUND A previously published study reported on the nonlinear behaviour for airway pressure and tidal volume of the adjustable pressure-limiting (APL) valve of the Aisys CS2 anaesthesia machine (GE Healthcare, Madison, Wisconsin, USA) during manual bag ventilation. In co-operation with the manufacturer, an adapted APL valve was developed. OBJECTIVE To test and characterise the performance of an adapted APL valve and assess its clinical usability. DESIGN Two-stage study, consisting of an in-vitro testing of an adapted APL valve in a baby and adolescent lung model, followed by a clinical experience survey of anaesthesia personnel after the official implementation of the new APL valve into clinical routine. SETTING Anaesthesia Department at the University Children's Hospital Zurich. MAIN OUTCOME MEASURES Airway pressures and inspiratory tidal volumes during opening and closure of the APL valve at different settings. Likert scale assessment of performance expectance, effort expectance, behavioural intention and safety of the APL valve during clinical use. RESULTS In contrast to the original APL valve of the GE Aisys CS2, the adapted APL valve showed a nearly linear increase in airway pressures as well as in the tidal volumes measured. Most importantly, the measured pressures never exceeded the set pressures. Based on the experimental findings, all original APL valves of the GE Aisys CS2 were replaced by the adapted APL valve. Two months later, an anonymised and standardised questionnaire was handed out to all employees working with the adapted APL valve. Analysis of the questionnaire indicated that the adapted APL valve is easier and more precise to handle in the daily routine than the original one. CONCLUSION The newly adapted APL valve for the GE Aisys CS2 has considerably improved its linearity at lower pressures and supports our institution's bag mask ventilation practices

    The importance of intravenous immunoglobulin treatment in critically ill patients with necrotizing soft tissue infection: a retrospective cohort study.

    Get PDF
    BACKGROUND Necrotizing soft-tissue infections are infections with high mortality. The use of immunoglobulins within a combination therapy including broad-spectrum antibiotics has been debated. We assessed potential benefits of immunoglobulins and hypothesized that they were associated with a treatment benefit in a high-resource setting. METHODS Patients with necrotizing soft-tissue infection hospitalized in the tertiary intensive care unit of the University Hospital of Zurich, Switzerland, between 2008 and 2020 were included retrospectively. The association between immunoglobulin administration and in-hospital survival, intensive care unit length of stay, the incidences of acute renal failure, acute respiratory distress syndrome and septic shock were analyzed. RESULTS After adjustment for confounders, no difference for in-hospital survival (hazard ratio 2.20, 95% confidence interval [CI] 0.24-20.20, p = 0.5), intensive care unit length of stay (subhazard ratio [SHR] 0.90, CI 0.41-1.98, p = 0.8) and the development of acute respiratory distress syndrome (SHR 1.2, CI 0.36-4.03, p = 0.77) was observed in patients with or without immunoglobulin treatment. The Simplified Acute Physiology Score II, the risk of developing acute renal failure (SHR 2.86, CI 1.33-6.15, p = 0.01) and septic shock (SHR 1.86, CI 1.02-3.40, p = 0.04) was higher in patients treated with immunoglobulins, possibly reflecting a higher disease severity beyond measured confounders. CONCLUSIONS No clear evidence for a benefit of immunoglobulins in our cohort with consistent antibiotic use was found. Patients receiving immunoglobulins appeared more severely ill. Complementary to high treatment standards and appropriate antibiotics including beta lactams and protein synthesis inhibitors, immunoglobulins should be administered on a case-to-case basis, at least while more evidence from larger randomized controlled trials is missing

    Bacterial but no SARS-CoV-2 contamination after terminal disinfection of tertiary care intensive care units treating COVID-19 patients

    Full text link
    BACKGROUND In intensive care units (ICUs) treating patients with Coronavirus disease 2019 (COVID-19) invasive ventilation poses a high risk for aerosol and droplet formation. Surface contamination of severe acute respiratory syndrome Coronavirus 2 (SARS-CoV-2) or bacteria can result in nosocomial transmission. METHODS Two tertiary care COVID-19 intensive care units treating 53 patients for 870 patient days were sampled after terminal cleaning and preparation for regular use to treat non-COVID-19 patients. RESULTS A total of 176 swabs were sampled of defined locations covering both ICUs. No SARS-CoV-2 ribonucleic acid (RNA) was detected. Gram-negative bacterial contamination was mainly linked to sinks and siphons. Skin flora was isolated from most swabbed areas and Enterococcus faecium was detected on two keyboards. CONCLUSIONS After basic cleaning with standard disinfection measures no remaining SARS-CoV-2 RNA was detected. Bacterial contamination was low and mainly localised in sinks and siphons

    Comparison of four clinical risk scores in comatose patients after out-of-hospital cardiac arrest.

    Get PDF
    BACKGROUND AND AIMS Several different scoring systems for early risk stratification after out-of-hospital cardiac arrest have been developed, but few have been validated in large datasets. The aim of the present study was to compare the well-validated Out-of-hospital Cardiac Arrest (OHCA) and Cardiac Arrest Hospital Prognosis (CAHP)-scores to the less complex MIRACLE2- and Target Temperature Management (TTM)-scores. METHODS This was a post-hoc analysis of the Targeted Hypothermia versus Targeted Normothermia after Out-of-Hospital Cardiac Arrest (TTM2) trial. Missing data were handled by multiple imputation. The primary outcome was discriminatory performance assessed as the area under the receiver operating characteristics-curve (AUROC), with the outcome of interest being poor functional outcome or death (modified Rankin Scale 4-6) at 6 months after OHCA. RESULTS Data on functional outcome at 6 months were available for 1829 cases, which constituted the study population. The pooled AUROC for the MIRACLE2-score was 0.810 (95% CI 0.790 - 0.828), 0.835 (95% CI 0.816 - 0.852) for the TTM-score, 0.820 (95% CI 0.800 - 0.839) for the CAHP-score and 0.770 (95% CI 0.748 - 0.791) for the OHCA-score. At the cut-offs needed to achieve specificities >95%, sensitivities were <40 % for all four scoring systems. CONCLUSIONS The TTM-, MIRACLE2- and CAHP-scores are all capable of providing objective risk estimates accurate enough to be used as part of a holistic patient assessment after OHCA of a suspected cardiac origin. Due to its simplicity, the MIRACLE2-score could be a practical solution for both clinical application and risk stratification within trials

    MoSBOTs: Magnetically Driven Biotemplated MoS2_2‐Based Microrobots for Biomedical Applications

    Full text link
    2D layered molybdenum disulfide (MoS2_2) nanomaterials are a promising platform for biomedical applications, particularly due to its high biocompatibility characteristics, mechanical and electrical properties, and flexible functionalization. Additionally, the bandgap of MoS2_2 can be engineered to absorb light over a wide range of wavelengths, which can then be transformed into local heat for applications in photothermal tissue ablation and regeneration. However, limitations such as poor stability of aqueous dispersions and low accumulation in affected tissues impair the full realization of MoS2_2 for biomedical applications. To overcome such challenges, herein, multifunctional MoS2_2-based magnetic helical microrobots (MoSBOTs) using cyanobacterium Spirulina platensis are proposed as biotemplate for therapeutic and biorecognition applications. The cytocompatible microrobots combine remote magnetic navigation with MoS2_2 photothermal activity under near-infrared irradiation. The resulting photoabsorbent features of the MoSBOTs are exploited for targeted photothermal ablation of cancer cells and on-the-fly biorecognition in minimally invasive oncotherapy applications. The proposed multi-therapeutic MoSBOTs hold considerable potential for a myriad of cancer treatment and diagnostic-related applications, circumventing current challenges of ablative procedures

    Magnetic PiezoBOTs: a microrobotic approach for targeted amyloid protein dissociation

    Full text link
    Piezoelectric nanomaterials have become increasingly popular in the field of biomedical applications due to their high biocompatibility and ultrasound-mediated piezocatalytic properties. In addition, the ability of these nanomaterials to disaggregate amyloid proteins, which are responsible for a range of diseases resulting from the accumulation of these proteins in body tissues and organs, has recently gained considerable attention. However, the use of nanoparticles in biomedicine poses significant challenges, including targeting and uncontrolled aggregation. To address these limitations, our study proposes to load these functional nanomaterials on a multifunctional mobile microrobot This microrobot is designed by coating magnetic and piezoelectric barium titanate nanoparticles on helical biotemplates, allowing for the combination of magnetic navigation and ultrasound-mediated piezoelectric effects to target amyloid disaggregation. Our findings demonstrate that acoustically actuated PiezoBOTs can effectively reduce the size of aggregated amyloid proteins by over 80% in less than 10 minutes by shortening and dissociating constituent amyloid fibrils. Moreover, the PiezoBOTs can be easily magnetically manipulated to actuate the piezocatalytic nanoparticles to specific amyloidosis-affected tissues or organs, minimizing side effects. These biocompatible PiezoBOTs offer a promising non-invasive therapeutic approach for amyloidosis diseases by targeting and breaking down protein aggregates at specific organ or tissue sites

    Outcomes of patients with acute respiratory failure on veno-venous extracorporeal membrane oxygenation requiring additional circulatory support by veno-venoarterial extracorporeal membrane oxygenation

    Full text link
    ObjectiveVeno-venous (V-V) extracorporeal membrane oxygenation (ECMO) is increasingly used to support patients with severe acute respiratory distress syndrome (ARDS). In case of additional cardio-circulatory failure, some experienced centers upgrade the V-V ECMO with an additional arterial return cannula (termed V-VA ECMO). Here we analyzed short- and long-term outcome together with potential predictors of mortality.DesignMulticenter, retrospective analysis between January 2008 and September 2021.SettingThree tertiary care ECMO centers in Germany (Hannover, Bonn) and Switzerland (Zurich).PatientsSeventy-three V-V ECMO patients with ARDS and additional acute cardio-circulatory deterioration required an upgrade to V-VA ECMO were included in this study.Measurements and main resultsFifty-three patients required an upgrade from V-V to V-VA and 20 patients were directly triple cannulated. Median (Interquartile Range) age was 49 (28–57) years and SOFA score was 14 (12–17) at V-VA ECMO upgrade. Vasoactive-inotropic score decreased from 53 (12–123) at V-VA ECMO upgrade to 9 (3–37) after 24 h of V-VA ECMO support. Weaning from V-VA and V-V ECMO was successful in 47 (64%) and 40 (55%) patients, respectively. Duration of ECMO support was 12 (6–22) days and ICU length of stay was 32 (16–46) days. Overall ICU mortality was 48% and hospital mortality 51%. Two additional patients died after hospital discharge while the remaining patients survived up to two years (with six patients being lost to follow-up). The vast majority of patients was free from higher degree persistent organ dysfunction at follow-up. A SOFA score &gt; 14 and higher lactate concentrations at the day of V-VA upgrade were independent predictors of mortality in the multivariate regression analysis.ConclusionIn this analysis, the use of V-VA ECMO in patients with ARDS and concomitant cardiocirculatory failure was associated with a hospital survival of about 50%, and most of these patients survived up to 2 years. A SOFA score &gt; 14 and elevated lactate levels at the day of V-VA upgrade predict unfavorable outcome
    • 

    corecore