71 research outputs found

    Low-Stroke Actuation for a Serial Robot

    Get PDF
    A serial robot includes a base, first and second segments, a proximal joint joining the base to the first segment, and a distal joint. The distal joint that joins the segments is serially arranged and distal with respect to the proximal joint. The robot includes first and second actuators. A first tendon extends from the first actuator to the proximal joint and is selectively moveable via the first actuator. A second tendon extends from the second actuator to the distal joint and is selectively moveable via the second actuator. The robot includes a transmission having at least one gear element which assists rotation of the distal joint when an input force is applied to the proximal and/or distal joints by the first and/or second actuators. A robotic hand having the above robot is also disclosed, as is a robotic system having a torso, arm, and the above-described hand

    Improved Stability of Haptic Human-Robot Interfaces using Measurement of Human Arm Stiffness

    Get PDF
    Copyright © Taylor and FrancisDOI: http://dx.doi.org/10.1080/01691864.2014.900162Necessary physical contact between an operator and a force feedback haptic device creates a coupled system consisting of human and machine. This contact, combined with the natural human tendency to increase arm stiffness to attempt to stabilize its motion, can reduce the stability of the system. This paper proposes a method to increase stability on demand while maintaining speed and performance. Operator arm stiffness is not directly measurable, so controllers cannot typically account for this issue. The causes of arm end-point stiffness are examined as related to system stability, and a method for estimating changes in arm stiffness based on arm muscle activity was designed to provide a robotic controller with additional information about the operator. This was accomplished using electromyograms (EMGs) to measure muscle activities and estimating the level of arm stiffness, which was used to adjust the dynamic characteristics of an impedance controller. To support this design, the correlation between EMGs and arm stiffness was validated experimentally. Further experiments characterized the effects of the designed system on operator performance. This showed increased stability and faster, more accurate movements using the compensating system. Such a system could be used in many applications, including force assisting devices in industrial facilities

    Single-shot compressed ultrafast photography: a review

    Get PDF
    Compressed ultrafast photography (CUP) is a burgeoning single-shot computational imaging technique that provides an imaging speed as high as 10 trillion frames per second and a sequence depth of up to a few hundred frames. This technique synergizes compressed sensing and the streak camera technique to capture nonrepeatable ultrafast transient events with a single shot. With recent unprecedented technical developments and extensions of this methodology, it has been widely used in ultrafast optical imaging and metrology, ultrafast electron diffraction and microscopy, and information security protection. We review the basic principles of CUP, its recent advances in data acquisition and image reconstruction, its fusions with other modalities, and its unique applications in multiple research fields

    An articulated assistive robot for intuitive hands-on-payload manipulation

    Get PDF
    This paper presents an intelligent assistive robot designed to help operators in lifting and moving large payloads through direct physical contact (hands-on-payload mode). The mechanical design of the robot is first presented. Although its kinematics are similar to that of a cable-suspended system, the proposed mechanism is based on articulated linkages, thereby allowing the payload to be offset from the rail support on which it is suspended. A dynamic model of the robot is then developed. It is shown that a simplified dynamic model can be obtained using geometric assumptions. Based on the simplified dynamic model, a controller is then presented that handles the physical human-robot interaction and that provides the operator with an intuitive direct control of the payload. Experimental validation on a full-scale prototype is presented in order to demonstrate the effectiveness of the proposed robot and controller

    Genome-Wide Association Studies Identified Three Independent Polymorphisms Associated with α-Tocopherol Content in Maize Kernels

    Get PDF
    Tocopherols are a class of four natural compounds that can provide nutrition and function as antioxidant in both plants and animals. Maize kernels have low α-tocopherol content, the compound with the highest vitamin E activity, thus, raising the risk of vitamin E deficiency in human populations relying on maize as their primary vitamin E source. In this study, two insertion/deletions (InDels) within a gene encoding γ-tocopherol methyltransferase, Zea mays VTE4 (ZmVTE4), and a single nucleotide polymorphism (SNP) located ∼85 kb upstream of ZmVTE4 were identified to be significantly associated with α-tocopherol levels in maize kernels by conducting an association study with a panel of ∼500 diverse inbred lines. Linkage analysis in three populations that segregated at either one of these three polymorphisms but not at the other two suggested that the three polymorphisms could affect α-tocopherol content independently. Furthermore, we found that haplotypes of the two InDels could explain ∼33% of α-tocopherol variation in the association panel, suggesting ZmVTE4 is a major gene involved in natural phenotypic variation of α-tocopherol. One of the two InDels is located within the promoter region and associates with ZmVTE4 transcript level. This information can not only help in understanding the underlying mechanism of natural tocopherol variations in maize kernels, but also provide valuable markers for marker-assisted breeding of α-tocopherol content in maize kernels, which will then facilitate the improvement of maize as a better source of daily vitamin E nutrition

    Single-shot compressed ultrafast photography: a review

    Get PDF
    Compressed ultrafast photography (CUP) is a burgeoning single-shot computational imaging technique that provides an imaging speed as high as 10 trillion frames per second and a sequence depth of up to a few hundred frames. This technique synergizes compressed sensing and the streak camera technique to capture nonrepeatable ultrafast transient events with a single shot. With recent unprecedented technical developments and extensions of this methodology, it has been widely used in ultrafast optical imaging and metrology, ultrafast electron diffraction and microscopy, and information security protection. We review the basic principles of CUP, its recent advances in data acquisition and image reconstruction, its fusions with other modalities, and its unique applications in multiple research fields

    Evaluation of Functional Characteristics of Precision Finished Surfaces

    Get PDF

    Control limitation analysis for dissipative passive haptic interfaces

    Get PDF
    This research addresses the ability of dissipative passive actuators to generate control effects on a passive haptic interface. A haptic display is a human-machine interface that constructs a sensation of touch for the human operator. Applications can be found in various industries, space, medicine and construction etc. A dissipative passive haptic display contains passive actuators that can remove energy from the system by resisting motions in the system. The advantage of a dissipative passive haptic display is better safety compared to an active display. Its disadvantage is the limited control ability from the passive actuators. This research starts with the identification of the control ability and limitations of dissipative passive haptic interfaces. The ability is identified as the steerability, the ability to redirect motions of a manipulator. The force generation analysis of each individual actuator is then selected as an approach to evaluate the steerability. Steerability metrics are defined to evaluate the steerability. Even though non-redundant manipulators dont have desired steerability, optimal steering configurations are found for the best operation. Steerability is improved by redundancy in serial or parallel structures. A theorem is developed to evaluate steerability for redundant manipulators. The influence of system dynamics on their steerabilities is discussed. Previously developed haptic interfaces are evaluated based on their steerabilities. Steerability analysis of three-dimensional haptic interfaces is also given to a limited extent as an extension of the two-dimensional cases. Brakes and clutches are the two types of dissipative passive actuators in this research.Ph.D.Committee Chair: Book, Wayne; Committee Member: Arkin, Ronald; Committee Member: DeWeerth, Steve; Committee Member: Ebert-Uphoff, Imme; Committee Member: Vito, Raymon
    • …
    corecore