37 research outputs found

    Molecular dynamics study of the fragmentation of silicon doped fullerenes

    Full text link
    Tight binding molecular dynamics simulations, with a non orthogonal basis set, are performed to study the fragmentation of carbon fullerenes doped with up to six silicon atoms. Both substitutional and adsorbed cases are considered. The fragmentation process is simulated starting from the equilibrium configuration in each case and imposing a high initial temperature to the atoms. Kinetic energy quickly converts into potential energy, so that the system oscillates for some picoseconds and eventually breaks up. The most probable first event for substituted fullerenes is the ejection of a C2 molecule, another very frequent event being that one Si atom goes to an adsorbed position. Adsorbed Si clusters tend to desorb as a whole when they have four or more atoms, while the smaller ones tend to dissociate and sometimes interchange positions with the C atoms. These results are compared with experimental information from mass abundance spectroscopy and the products of photofragmentation.Comment: Seven two-column pages, six postscript figures. To be published in Physical Review

    Pilot scale validation campaign of gel dosimetry for pre-treatment quality assurance in stereotactic radiotherapy

    Get PDF
    Purpose: Complex stereotactic radiotherapy treatment plans require prior verification. A gel dosimetry system was developed and tested to serve as a high-resolution 3D dosimeter for Quality Assurance (QA) purposes.Materials and Methods: A modified version of a polyacrylamide polymer gel dosimeter based on chemical response inhibition was employed. Different sample geometries (cuvettes and phantoms) were manufactured for calibration and QA acquisitions. Irradiations were performed with a Varian Trilogy linac, and analyses of irradiated gel dosimeters were performed via MRI with a 1.5 T Philips Achieva at 1 mm3 or 2 mm3 isotropic spatial resolution. To assess reliability of polymer gel data, 54 stereotactic clinical treatment plans were delivered both on dosimetric gel phantoms and on the Delta4 dosimeter. Results from the two devices were evaluated through a global gamma index over a range of acceptance criteria and compared with each other.Results: A quantitative and tunable control of dosimetric gel response sensitivity was achieved through chemical inhibition. An optimized MRI analysis protocol allowed to acquire high resolution phantom dose data in time -frames of approximate to 1 h. Conversion of gel dosimeter data into absorbed dose was achieved through internal calibration. Polymer gel dosimeters (2 mm3 resolution) and Delta4 presented an agreement within 4.8 % and 2.7 % at the 3 %/1 mm and 2 %/2 mm gamma criteria, respectively.Conclusions: Gel dosimeters appear as promising tools for high resolution 3D QA. Added complexity of the gel dosimetry protocol may be justifiable in case of small target volumes and steep dose gradients

    Complications associated with transobturator sling procedures: analysis of 233 consecutive cases with a 27 months follow-up

    Get PDF
    <p>Abstract</p> <p>Backround</p> <p>The transobturator tape procedure (TOT) is an effective surgical treatment of female stress urinary incontinence. However data concerning safety are rare, follow-up is often less than two years, and complications are probably underreported. The aim of this study was to describe early and late complications associated with TOT procedures and identify risk factors for erosions.</p> <p>Methods</p> <p>It was a 27 months follow-up of a cohort of 233 women who underwent TOT with three different types of slings (Aris<sup>®</sup>, Obtape<sup>®</sup>, TVT-O<sup>®</sup>). Follow-up information was available for 225 (96.6%) women.</p> <p>Results</p> <p>There were few per operative complications. Forty-eight women (21.3%) reported late complications including <it>de novo </it>or worsening of preexisting urgencies (10.2%), perineal pain (2.2%), <it>de novo </it>dyspareunia (9%), and vaginal erosion (7.6%). The risk of erosion significantly differed between the three types of slings and was 4%, 17% and 0% for Aris<sup>®</sup>, Obtape<sup>® </sup>and TVT-O<sup>® </sup>respectively (P = 0.001). The overall proportion of women satisfied by the procedure was 72.1%. The percentage of women satisfied was significantly lower in women who experienced erosion (29.4%) compared to women who did not (78.4%) (RR 0.14, 95% CI 0.05-0.38, P < 0.001).</p> <p>Conclusion</p> <p>Late post operative complications are relatively frequent after TOT and can impair patient's satisfaction. Women should be informed of these potential complications preoperatively and require careful follow-up after the procedure. Choice of the safest sling material is crucial as it is a risk factor for erosion.</p

    Ab initio simulation of laser-induced transformations in fullerite

    No full text
    We studied by ab initio molecular dynamics the modifications induced on fullerite by irradiation with ultrashort, very intense laser pulses. We identified the threshold for the nonthermal cage opening of the C-60 molecules that is the analog of the laser-induced nonthermal melting observed in semiconductors and graphite. The new phase formed by the nonthermal coalescence of the C-60 molecules is fluidlike and mainly formed by small chains of twofold-coordinated atoms. An estimate of the threshold laser fluence for the nonthermal transformation is given

    Nationalist Lionel Thomas Courtenay addressing a meeting at the St James Hall, 7 March 1931, 1 [picture].

    No full text
    Title devised from accompanying information where available.; Part of the: Fairfax archive of glass plate negatives.; Fairfax number: 3636 and 2603.; Also available online at: http://nla.gov.au/nla.pic-vn6217758; Acquired from Fairfax Media, 2012
    corecore