672 research outputs found

    Potential implications of practice effects in Alzheimer's disease prevention trials.

    Get PDF
    IntroductionPractice effects (PEs) present a potential confound in clinical trials with cognitive outcomes. A single-blind placebo run-in design, with repeated cognitive outcome assessments before randomization to treatment, can minimize effects of practice on trial outcome.MethodsWe investigated the potential implications of PEs in Alzheimer's disease prevention trials using placebo arm data from the Alzheimer's Disease Cooperative Study donepezil/vitamin E trial in mild cognitive impairment. Frequent ADAS-Cog measurements early in the trial allowed us to compare two competing trial designs: a 19-month trial with randomization after initial assessment, versus a 15-month trial with a 4-month single-blind placebo run-in and randomization after the second administration of the ADAS-Cog. Standard power calculations assuming a mixed-model repeated-measure analysis plan were used to calculate sample size requirements for a hypothetical future trial designed to detect a 50% slowing of cognitive decline.ResultsOn average, ADAS-Cog 13 scores improved at first follow-up, consistent with a PE and progressively worsened thereafter. The observed change for a 19-month trial (1.18 points) was substantively smaller than that for a 15-month trial with 4-month run-in (1.79 points). To detect a 50% slowing in progression under the standard design (i.e., a 0.59 point slowing), a future trial would require 3.4 times more subjects than would be required to detect the comparable percent slowing (i.e., 0.90 points) with the run-in design.DiscussionAssuming the improvement at first follow-up observed in this trial represents PEs, the rate of change from the second assessment forward is a more accurate representation of symptom progression in this population and is the appropriate reference point for describing treatment effects characterized as percent slowing of symptom progression; failure to accommodate this leads to an oversized clinical trial. We conclude that PEs are an important potential consideration when planning future trials

    Tau oligomers in cerebrospinal fluid in Alzheimer's disease

    Get PDF
    OBJECTIVE: With an increasing incidence of Alzheimer's disease (AD) and neurodegenerative tauopathies, there is an urgent need to develop reliable biomarkers for the diagnosis and monitoring of the disease, such as the recently discovered toxic tau oligomers. Here, we aimed to demonstrate the presence of tau oligomers in the cerebrospinal fluid (CSF) of patients with cognitive deficits, and to determine whether tau oligomers could serve as a potential biomarker for AD. METHODS: A multicentric collaborative study involving a double-blinded analysis with a total of 98 subjects with moderate to severe AD (N = 41), mild AD (N = 31), and nondemented control subjects (N = 26), and two pilot studies of 33 total patients with AD (N = 19) and control (N = 14) subjects were performed. We carried out biochemical assays to measure oligomeric tau from CSF of these patients with various degrees of cognitive impairment as well as cognitively normal controls. RESULTS: Using a highly reproducible indirect ELISA method, we found elevated levels of tau oligomers in AD patients compared to age-matched controls. Western blot analysis confirmed the presence of oligomeric forms of tau in CSF. In addition, the ratio of oligomeric to total tau increased in the order: moderate to severe AD, mild AD, and controls. CONCLUSION: These assays are suitable for the analysis of human CSF samples. These results here suggest that CSF tau oligomer measurements could be optimized and added to the panel of CSF biomarkers for the accurate and early detection of AD

    NT1-Tau Is Increased in CSF and Plasma of CJD Patients, and Correlates with Disease Progression

    Get PDF
    This study investigates the diagnostic and prognostic potential of different forms of tau in biofluids from patients with Creutzfeldt-Jakob disease (CJD). Extracellular tau, which is molecularly heterogeneous, was measured using ultra-sensitive custom-made Simoa assays for N-terminal (NT1), mid-region, and full-length tau. We assessed cross-sectional CSF and plasma from healthy controls, patients with Alzheimer’s disease (AD) and CJD patients. Then, we evaluated the correlation of the best-performing tau assay (NT1-tau) with clinical severity and functional decline (using the MRC Prion Disease Rating Scale) in a longitudinal CJD cohort (n = 145). In a cross-sectional study, tau measured in CSF with the NT1 and mid-region Simoa assays, separated CJD (n = 15) from AD (n = 18) and controls (n = 21) with a diagnostic accuracy (AUCs: 0.98–1.00) comparable to or better than neurofilament light chain (NfL; AUCs: 0.96–0.99). In plasma, NT1-measured tau was elevated in CJD (n = 5) versus AD (n = 15) and controls (n = 15). Moreover, in CJD plasma (n = 145) NT1-tau levels correlated with stage and rate of disease progression, and the effect on clinical progression was modified by the PRNP codon 129. Our findings suggest that plasma NT1-tau shows promise as a minimally invasive diagnostic and prognostic biomarker of CJD, and should be further investigated for its potential to monitor disease progression and response to therapies

    Tau protein, A beta 42 and S-100B protein in cerebrospinal fluid of patients with dementia with Lewy bodies

    Get PDF
    The intra vitam diagnosis of dementia with Lewy bodies (DLB) is still based on clinical grounds. So far no technical investigations have been available to support this diagnosis. As for tau protein and beta-amyloid((1-42)) (Abeta42), promising results for the diagnosis of Alzheimer's disease ( AD) have been reported; we evaluated these markers and S-100B protein in cerebrospinal fluid (CSF), using a set of commercially available assays, of 71 patients with DLB, 67 patients with AD and 41 nondemented controls (NDC) for their differential diagnostic relevance. Patients with DLB showed significantly lower tau protein values compared to AD but with a high overlap of values. More prominent differences were observed in the comparison of DLB patients with all three clinical core features and AD patients. Abeta42 levels were decreased in the DLB and AD groups versus NDC, without significant subgroup differences. S-100B levels were not significantly different between the groups. Tau protein levels in CSF may contribute to the clinical distinction between DLB and AD, but the value of the markers is still limited especially due to mixed pathology. We conclude that more specific markers have to be established for the differentiation of these diseases. Copyright (C) 2005 S. Karger AG, Basel

    SCRN1: A cerebrospinal fluid biomarker correlating with tau in Alzheimer's disease

    Get PDF
    INTRODUCTION: Secernin-1 (SCRN1) is a neuronal protein that co-localizes with neurofibrillary tangles in Alzheimer's disease (AD), but not with tau inclusions in corticobasal degeneration (CBD), progressive supranuclear palsy (PSP), or Pick's disease. METHODS: We measured SCRN1 concentration in cerebrospinal fluid (CSF) using a novel mass spectrometric parallel reaction monitoring method in three clinical cohorts comprising patients with neurochemically characterized AD (n = 25) and controls (n = 28), clinically diagnosed Parkinson's disease (PD; n = 38), multiple system atrophy (MSA; n = 31), PSP (n = 20), CBD (n = 8), healthy controls (n = 37), and neuropathology-confirmed AD (n = 47). RESULTS: CSF SCRN1 was significantly increased in AD (P < 0.01, fold change = 1.4) compared to controls (receiver operating characteristic area under the curve = 0.78) but not in CBD, PSP, PD, or MSA. CSF SCRN1 positively correlated with CSF total tau (R = 0.78, P = 1.1 × 10−13), phosphorylated tau181 (R = 0.64, P = 3.2 × 10−8), and Braak stage and negatively correlated with Mini-Mental State Examination score. DISCUSSION: CSF SCRN1 is a candidate biomarker of AD, reflecting tau pathology

    Validation of Serum Neurofilament Light Chain as a Biomarker of Parkinson's Disease Progression

    Get PDF
    Background: The objective of this study was to assess neurofilament light chain as a Parkinson’s disease biomarker. Methods: We quantified neurofilament light chain in 2 independent cohorts: (1) longitudinal cerebrospinal fluid samples from the longitudinal de novo Parkinson’s disease cohort and (2) a large longitudinal cohort with serum samples from Parkinson’s disease, other cognate/neurodegenerative disorders, healthy controls, prodromal conditions, and mutation carriers. Results: In the Parkinson’s Progression Marker Initiative cohort, mean baseline serum neurofilament light chain was higher in Parkinson’s disease patients (13 � 7.2 pg/mL) than in controls (12 � 6.7 pg/mL), P = 0.0336. Serum neurofilament light chain increased longitudinally in Parkinson’s disease patients versus controls (P < 0.01). Motor scores were positively associated with neurofilament light chain, whereas some cognitive scores showed a negative association. Conclusions: Neurofilament light chain in serum samples is increased in Parkinson’s disease patients versus healthy controls, increases over time and with age, and correlates with clinical measures of Parkinson’s disease severity. Although the specificity of neurofilament light chain for Parkinson’s disease is low, it is the first blood-based biomarker candidate that could support disease stratification of Parkinson’s disease versus other cognate/neurodegenerative disorders, track clinical progression, and possibly assess responsiveness to neuroprotective treatments. However, use of neurofilament light chain as a biomarker of response to neuroprotective interventions remains to be assessed

    Comparison of Pittsburgh compound B and florbetapir in cross-sectional and longitudinal studies.

    Get PDF
    IntroductionQuantitative in vivo measurement of brain amyloid burden is important for both research and clinical purposes. However, the existence of multiple imaging tracers presents challenges to the interpretation of such measurements. This study presents a direct comparison of Pittsburgh compound B-based and florbetapir-based amyloid imaging in the same participants from two independent cohorts using a crossover design.MethodsPittsburgh compound B and florbetapir amyloid PET imaging data from three different cohorts were analyzed using previously established pipelines to obtain global amyloid burden measurements. These measurements were converted to the Centiloid scale to allow fair comparison between the two tracers. The mean and inter-individual variability of the two tracers were compared using multivariate linear models both cross-sectionally and longitudinally.ResultsGlobal amyloid burden measured using the two tracers were strongly correlated in both cohorts. However, higher variability was observed when florbetapir was used as the imaging tracer. The variability may be partially caused by white matter signal as partial volume correction reduces the variability and improves the correlations between the two tracers. Amyloid burden measured using both tracers was found to be in association with clinical and psychometric measurements. Longitudinal comparison of the two tracers was also performed in similar but separate cohorts whose baseline amyloid load was considered elevated (i.e., amyloid positive). No significant difference was detected in the average annualized rate of change measurements made with these two tracers.DiscussionAlthough the amyloid burden measurements were quite similar using these two tracers as expected, difference was observable even after conversion into the Centiloid scale. Further investigation is warranted to identify optimal strategies to harmonize amyloid imaging data acquired using different tracers
    • …
    corecore