51 research outputs found

    Deciphering Plant-Insect-Microorganism Signals for Sustainable Crop Production

    Get PDF
    Agricultural crop productivity relies on the application of chemical pesticides to reduce pest and pathogen damage. However, chemical pesticides also pose a range of ecological, environmental and economic penalties. This includes the development of pesticide resistance by insect pests and pathogens, rendering pesticides less effective. Alternative sustainable crop protection tools should therefore be considered. Semiochemicals are signalling molecules produced by organisms, including plants, microbes, and animals, which cause behavioural or developmental changes in receiving organisms. Manipulating semiochemicals could provide a more sustainable approach to the management of insect pests and pathogens across crops. Here, we review the role of semiochemicals in the interaction between plants, insects and microbes, including examples of how they have been applied to agricultural systems. We highlight future research priorities to be considered for semiochemicals to be credible alternatives to the application of chemical pesticides

    Радиографический метод контроля сварных швов трубопроводов

    Get PDF
    Обнаружение дефектов сварных соединений является одной из основных задач неразрушающего контроля, применяемого для диагностики технического состояния трубопроводов различного назначения. Среди методов неразрушающего контроля широкое распространение получил радиографический метод. Для обработки изображений, полученных радиографическим методом, и обнаружения дефектов сварки, используются различные алгоритмы. Одним из перспективных алгоритмов обработки изображений является алгоритм, основанный на методе нейронной сети.Detection of defects in welded joints is one of the main tasks of non-destructive testing used for diagnostics of the technical condition of pipelines for various purposes. Among the methods of nondestructive testing, the radiographic method is widely used. For processing images obtained by radiographic method, and the detection of welding defects, various algorithms are used. One of the promising algorithms for image processing is an algorithm based on the neural network method

    Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)

    Get PDF

    Guidelines for the use and interpretation of assays for monitoring autophagy (4th edition)1.

    Get PDF
    In 2008, we published the first set of guidelines for standardizing research in autophagy. Since then, this topic has received increasing attention, and many scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Thus, it is important to formulate on a regular basis updated guidelines for monitoring autophagy in different organisms. Despite numerous reviews, there continues to be confusion regarding acceptable methods to evaluate autophagy, especially in multicellular eukaryotes. Here, we present a set of guidelines for investigators to select and interpret methods to examine autophagy and related processes, and for reviewers to provide realistic and reasonable critiques of reports that are focused on these processes. These guidelines are not meant to be a dogmatic set of rules, because the appropriateness of any assay largely depends on the question being asked and the system being used. Moreover, no individual assay is perfect for every situation, calling for the use of multiple techniques to properly monitor autophagy in each experimental setting. Finally, several core components of the autophagy machinery have been implicated in distinct autophagic processes (canonical and noncanonical autophagy), implying that genetic approaches to block autophagy should rely on targeting two or more autophagy-related genes that ideally participate in distinct steps of the pathway. Along similar lines, because multiple proteins involved in autophagy also regulate other cellular pathways including apoptosis, not all of them can be used as a specific marker for bona fide autophagic responses. Here, we critically discuss current methods of assessing autophagy and the information they can, or cannot, provide. Our ultimate goal is to encourage intellectual and technical innovation in the field

    Die isolierte spontane Dissektion der Arteria mesenterica superior als seltene Ursache eines akuten Abdomens

    No full text

    Diagnostik von Duenndarmtumoren mit Hilfe des CT-Enteroklysma. Die CT--Sellink ausgewertet bei 63 Patienten [Diagnosis of tumors of the small intestine with the aid of CT contrast enema. Sellink CT technique evaluated in 63 patients]

    No full text
    Purpose: Aim ofthe sludy was to compare the visualisation of small bowel tumours particularly Iymphoma of the small bowel by enteroclysma, computed tomography (CT) and computed tomography following enteroclysma. Methods: We examincd 97 examinations in 63 patients. Non Hoclgkin's Lymphoma was the primary malignancy in 44 patients, metastasis of different malignancies in 8 patients, primary malignancies of the small intestine in 5 patients, mesenteric tumours in 4 patients and postoperative stricture in another 2 patients. CT following enteroclysma (CT Sellink) was performed as helical CT in 55 patientsandas incremental CT in 42 patients. Examinations were evaluated by two radiologists. Evaluation criteria were small bowel distension, perceptibility of details and topographic conelation. Results: Manifestations of Iymphoma were found in 32 patients, infiltration of bowel wall in 12 patients. In three patients metastases of melanoma were found. In three patients the suspicion for small bowel tumours was not verified in CT Sellink. The perceptibility of details was evaluated as ameliorated in 45.5% of examinations over all. Conclusions: CT Seilink offers remarkable advantages in the diagnosis of small bowel tumours compared with enteroclysma and "conventional" computed tomography under intra-venous and oral cantrast media. CT Sellink was feasible over a time of 7 years now in clinical praxis. This examination represents an optimized standardinsmall intestine examination

    Diagnostik von Duenndarmtumoren mit Hilfe des CT-Entreoklysma : Die CT - Sellink ausgewertet bei 63 Patienten

    No full text
    Purpose: Aim of the study was to compare the visualisation of small bowel tumours particularly lymphoma of the small bowel by enteroclysma, computed tomography (CT) and computed tomography following enteroclysma. Methods: We examined 97 examinations in 63 patients. Non Hodgkin's Lymphoma was the primary malignancy in 44 patients, metastasis of different malignancies in 8 patients, primary malignancies of the small intestine in 5 patients, mesenteric tumours in 4 patients and postoperative stricture in another 2 patients. CT following enteroclysma (CT Sellink) was performed as helical CT in 55 patients and as incremental CT in 42 patients. Examinations were evaluated by two radiologists. Evaluation criteria were small bowel distension, perceptibility of details and topographic correlation. Results: Manifestations of lymphoma were found in 32 patients, infiltration of bowel wall in 12 patients. In three patients metastases of melanoma were found. In three patients the suspicion for small bowel tumours was not verified in CT Sellink. The perceptibility of details was evaluated as ameliorated in 45.5% of examinations over all. Conclusions: CT Sellink offers remarkable advantages in the diagnosis of small bowel tumours compared with enteroclysma and "conventional" computed tomography under intra-venous and oral contrast media. CT Sellink was feasible over a time of 7 years now in clinical praxis. This examination represents an optimized standard in small intestine examination
    corecore