22 research outputs found
St. Jude Trifecta Versus Carpentier-Edwards Perimount Magna valves for the treatment of aortic stenosis: comparison of early Doppler-Echocardiography and hemodynamic performance
Objective. Aim of this study was to compare the hemodynamic profiles of 2 aortic valve bioprostheses: the Carpentier Edwards Perimount Magna (CEPM) valve and the Trifecta valve. Methods. 100 patients who underwent AVR for severe symptomatic AS between September 2011 and October 2012 were analyzed by means of standard trans-thoracic Doppler-echocardiography. Results. Mean and peak gradients were significantly lower for the 21 mm Trifecta vs CEPM (11 ± 4 vs 15 ± 4 mmHg, and 20 ± 6 vs 26 ± 7 mmHg, respectively; all p < 0.05) and the 23 mm Trifecta vs CEPM (8 ± 2 vs 14 ± 4 mmHg, and 17 ± 6 vs 25 ± 9 mmHg; all p < 0.05). Effective orifice area tended to be slightly higher for the Trifecta valve. Conclusion. The new bioprosthetic valve Trifecta has an excellent hemodynamic profile, and lower trans-prosthesic gradients when compared to CEPM valve
A machine-learning based bio-psycho-social model for the prediction of non-obstructive and obstructive coronary artery disease
Background: Mechanisms of myocardial ischemia in obstructive and non-obstructive coronary artery disease (CAD), and the interplay between clinical, functional, biological and psycho-social features, are still far to be fully elucidated. Objectives: To develop a machine-learning (ML) model for the supervised prediction of obstructive versus non-obstructive CAD. Methods: From the EVA study, we analysed adults hospitalized for IHD undergoing conventional coronary angiography (CCA). Non-obstructive CAD was defined by a stenosisâ<â50% in one or more vessels. Baseline clinical and psycho-socio-cultural characteristics were used for computing a Rockwood and Mitnitski frailty index, and a gender score according to GENESIS-PRAXY methodology. Serum concentration of inflammatory cytokines was measured with a multiplex flow cytometry assay. Through an XGBoost classifier combined with an explainable artificial intelligence tool (SHAP), we identified the most influential features in discriminating obstructive versus non-obstructive CAD. Results: Among the overall EVA cohort (nâ=â509), 311 individuals (mean age 67â±â11 years, 38% females; 67% obstructive CAD) with complete data were analysed. The ML-based model (83% accuracy and 87% precision) showed that while obstructive CAD was associated with higher frailty index, older age and a cytokine signature characterized by IL-1ÎČ, IL-12p70 and IL-33, non-obstructive CAD was associated with a higher gender score (i.e., social characteristics traditionally ascribed to women) and with a cytokine signature characterized by IL-18, IL-8, IL-23. Conclusions: Integrating clinical, biological, and psycho-social features, we have optimized a sex- and gender-unbiased model that discriminates obstructive and non-obstructive CAD. Further mechanistic studies will shed light on the biological plausibility of these associations. Clinical trial registration: NCT02737982
The Sex-Specific Detrimental Effect of Diabetes and Gender-Related Factors on Pre-admission Medication Adherence Among Patients Hospitalized for Ischemic Heart Disease: Insights From EVA Study
Background: Sex and gender-related factors have been under-investigated as relevant determinants of health outcomes across non-communicable chronic diseases. Poor medication adherence results in adverse clinical outcomes and sex differences have been reported among patients at high cardiovascular risk, such as diabetics. The effect of diabetes and gender-related factors on medication adherence among women and men at high risk for ischemic heart disease (IHD) has not yet been fully investigated.Aim: To explore the role of sex, gender-related factors, and diabetes in pre-admission medication adherence among patients hospitalized for IHD.Materials and Methods: Data were obtained from the Endocrine Vascular disease Approach (EVA) (ClinicalTrials.gov Identifier: NCT02737982), a prospective cohort of patients admitted for IHD. We selected patients with baseline information regarding the presence of diabetes, cardiovascular risk factors, and gender-related variables (i.e., gender identity, gender role, gender relations, institutionalized gender). Our primary outcome was the proportion of pre-admission medication adherence defined through a self-reported questionnaire. We performed a sex-stratified analysis of clinical and gender-related factors associated with pre-admission medication adherence.Results: Two-hundred eighty patients admitted for IHD (35% women, mean age 70), were included. Around one-fourth of the patients were low-adherent to therapy before hospitalization, regardless of sex. Low-adherent patients were more likely diabetic (40%) and employed (40%). Sex-stratified analysis showed that low-adherent men were more likely to be employed (58 vs. 33%) and not primary earners (73 vs. 54%), with more masculine traits of personality, as compared with medium-high adherent men. Interestingly, women reporting medication low-adherence were similar for clinical and gender-related factors to those with medium-high adherence, except for diabetes (42 vs. 20%, p = 0.004). In a multivariate adjusted model only employed status was associated with poor medication adherence (OR 0.55, 95%CI 0.31â0.97). However, in the sex-stratified analysis, diabetes was independently associated with medication adherence only in women (OR 0.36; 95%CI 0.13â0.96), whereas a higher masculine BSRI was the only factor associated with medication adherence in men (OR 0.59, 95%CI 0.35â0.99).Conclusion: Pre-admission medication adherence is common in patients hospitalized for IHD, regardless of sex. However, patient-related factors such as diabetes, employment, and personality traits are associated with adherence in a sex-specific manner
XLIMus drug eluting stent : A randomIzed controlled Trial to assess endothelialization. The XLIMIT trial
Thin strut 3rd generation drug eluting stents offer the potential advantage over the previous generation of better technical performance and reduced neointimal proliferation parameters, which are linked to mid and late term device failure. To evaluate the performance of the Xlimus sirolimus-eluting stent (SES) against the Synergy everolimus-eluting stent (EES) in terms of device reendothelialization in patients undergoing PCI for coronary artery disease (CAD). Methods: XLIMIT is a multicenter randomized controlled trial targeting 180 patients requiring percutaneous coronary interventions (PCI). Patients will be treated with Xlimus SES or Synergy EES implantation and randomization will be performed in a 2:1 ratio. The primary endpoint will be the reendothelialization grade of the Xlimus stent in terms of strut coverage and neointimal hyperplasia volume as compared to Synergy. Secondary endpoints will be represented by clinical and procedural outcomes. The first patient was enrolled on February 2019. A clearer understanding of the endothelialization process of new generation DES could significantly impact the treatment with dual antiplatelet therapy in the future. Moreover, although not powered for clinical end-points, the XLIMIT trial will provide randomized data in a population with minimal exclusion criteria. Trial registration: ClinicalTrials.gov Identifier: NCT03745053. Registered on November 19, 2018
Valutazione dellâaggregazione piastrinica in cani affetti da leishmaniosi a diverso stadio clinico
The pressure/volume relationship during dobutamine stress echocardiography in transplanted heart: comparison with quality of life and coronary anatomy
Abstract Background Cardiac allograft vasculopathy (CAV) is a major late complication in cardiac transplant recipients and has a relevant impact on outcome of these patients. Aims of this study: to compare, in cardiac transplant recipients patients, the diagnostic value of pressure/volume relationship (ESPVR) during dobutamine stress echocardiography (DSE) for coronary artery disease, assessed by Multislice Computed Tomography (MSCT), and by coronary angiography (CA). We also analyzed any possible relationship between ESPVR and the Health Related Quality of Life of the patients (HRQoL), evaluated by SFâ36 questionnaire. Methods 25 consecutive patients underwent DSE within 24 hours after MSCT coronary angiogram and then they underwent CA. The HRQoL questionnaire was administered to the patients in the settings of DSE. They were followed-up for 6 months. Results DSE has a sensitivity in detecting CAV of 67%, specificity of 95%, positive predictive value of 67% and negative predictive value of 95%; DSE with ESPVR has a sensitivity of 100%, specificity of 95%, positive predictive value of 75%, negative predictive value of 100%; MSCT has a sensitivity of 100%; specificity of 82%; positive predictive value of 43%; negative predictive value of 100%. Htx recipients with a flat-biphasic ESPVR, although asymptomatic, perceived a worst HRQoL compared with the up-sloping ESPVR population, and this is statistically significant for the general health (p 0.0004), the vitality (p 0.0013) and the mental health (p 0.021) SF-36 subscale. Conclusions Evaluation with DSE and ESPVR is accurate in the clinical control of heart transplant recipients reserving invasive evaluation only for patients with abnormal contractility indexes.</p
Introduzione alla storia contemporanea
Il volume intende analizzare i caratteri peculiari dell'et\ue0 contemporanea attraverso alcuni saggi tematici e le principali cesure cronologiche dell'et\ue0 contemporanea. Con un'ottica comparativa il volume prende in esame l'arco cronologico che va dalle grandi rivoluzioni a cavallo tra sette e ottocento per arrivare fino all'11 settembre 2001
Transcatheter Aortic Valve Replacement With Self-Expanding ACURATE neo2: Postprocedural Hemodynamic and Short-Term Clinical Outcomes
The first-generation ACURATE neo transcatheter heart valve (THV) (Boston Scientific) was associated with a non-negligible occurrence of moderate or greater paravalvular aortic regurgitation (AR) following transcatheter aortic valve replacement. To overcome this issue, the ACURATE neo2 iteration, which incorporates a taller outer skirt aimed at reducing the occurrence of paravalvular AR, has recently been developed