1,591 research outputs found

    Quasimonoenergetic electron beam generation by using a pinholelike collimator in a self-modulated laser wakefield acceleration

    Get PDF
    A relativistic electron bunch with a large charge (>2 nC) was produced from a self-modulated laser wakefield acceleration configuration. For this experiment, an intense laser beam with a peak power of 2 TW and a duration of 700 fs was focused in a supersonic He gas jet, and relativistic high-energy electrons were observed from the strong laser-plasma interaction. By passing the electron bunch through a small pinholelike collimator, we could generate a quasimonoenergetic high-energy electron beam, in which electrons within a cone angle of 0.25 mrad (f/70) were selected. The beam clearly showed a narrow-energy-spread behavior with a central energy of 4.3 MeV and a charge of 200 pC. The acceleration gradient was estimated to be about 30 GeV/m. Particle-in-cell simulations were performed for comparison study and the result shows that both the experimental and simulation results are in good agreement and the electron trapping is initiated by the slow beat wave of the Raman backward wave and the incident laser pulse.open181

    Crystallization and preliminary X-ray crystallographic analysis of a yedU gene product from Escherichia coli

    Get PDF
    A yedU gene product with a molecular mass of 31 kDa is a hypothetical protein with no known function. The protein was purified and crystallized at 296 K. X-ray diffraction data have been collected to 2.3 Angstrom using synchrotron radiation. The crystals belong to the primitive orthorhombic system, with unit-cell parameters a = 50.56, b = 63.45, c = 168.02 Angstrom. The asymmetric unit contains two monomers of the protein, with a corresponding V-M of 2.25 Angstrom(3) Da(-1) and a solvent content of 44.84%.open2

    Intravenous Infusion Administration: A Comparative Study of Practices and Errors Between the United States and England and Their Implications for Patient Safety

    Get PDF
    Introduction Intravenous medication administration is widely reported to be error prone. Technologies such as smart pumps have been introduced with a view to reducing these errors. An international comparison could provide evidence of their effectiveness, including consideration of contextual factors such as regulatory systems and local cultures. Objectives The aim of this study was to investigate similarities and differences in practices and error types involving intravenous medication administration in the United States and England, and summarise methodological differences necessary to perform these parallel studies. Methods We drew on findings of separate point prevalence studies conducted across hospitals in each country. In these, we compared what was being administered at the time of observation with the prescription and relevant policies, errors were classified by type and severity, and proportions of infusions featuring each error type were calculated. We also reviewed what adaptations to the US protocol were needed for England. Authors independently reviewed findings from both studies and proposed themes for comparison. In online meetings, each country’s research team clarified assumptions and explained their findings. Results Key themes included commonalities and contrasts in methods, findings, practices and policies. Although US sites made greater use of smart infusion devices, and had more precisely defined requirements around infusion device use, patterns of errors were similar. Differences among clinical contexts within each country were as marked as differences across countries. Regulatory and quality control systems shape practices, but causal relationships are complex. Conclusion Infusion administration is a complex adaptive system with multiple interacting agents (professionals, patients, software systems, etc.) that respond in rich ways to their environments; safety depends on complex, interrelated factors

    UK experience of liver transplantation for erythropoietic protoporphyria

    Get PDF
    Erythropoietic protoporphyria (EPP) is characterised by excess production of free protoporphyrin from the bone marrow, most commonly due to deficiency of the enzyme ferrochelatase. Excess protoporphyrin gives rise to the cutaneous photosensitivity characteristic of the disease, and in a minority of patients leads to end-stage liver disease necessitating liver transplantation (LT). There is limited information regarding the timing, impact and long-term outcome of LT in such patients, thus we aimed to identify the indications and outcomes of all transplants performed for EPP in the UK using data from the UK Transplant Registry. Between 1987 and 2009, five patients underwent LT for EPP liver disease. Median follow-up was 60 months, and there were two deaths at 44 and 95 months from causes unrelated to liver disease. The remaining recipients are alive at 22.4 years, 61 months and 55 months after transplant. A high rate of postoperative biliary stricturing requiring multiple biliary interventions was observed. Recurrent EPP-liver disease occurred in 4/5 (80%) of patients but graft failure has not been observed. Given the role of biliary obstruction in inducing EPP-mediated liver damage, we suggest that consideration should be given for construction of a Roux loop at the time of transplant. Thus we demonstrate that although EPP liver transplant recipients have a good long-term survival, comparable to patients undergoing LT for other indications, biliary complications and disease recurrence are almost universal, and bone marrow transplantation should be considered where possible

    Evaluation of the health-related quality of life of children in Schistosoma haematobium-endemic communities in Kenya: a cross-sectional study.

    Get PDF
    BACKGROUND: Schistosomiasis remains a global public health challenge, with 93% of the ~237 million infections occurring in sub-Saharan Africa. Though rarely fatal, its recurring nature makes it a lifetime disorder with significant chronic health burdens. Much of its negative health impact is due to non-specific conditions such as anemia, undernutrition, pain, exercise intolerance, poor school performance, and decreased work capacity. This makes it difficult to estimate the disease burden specific to schistosomiasis using the standard DALY metric. METHODOLOGY/PRINCIPAL FINDINGS: In our study, we used Pediatric Quality of Life Inventory (PedsQL), a modular instrument available for ages 2-18 years, to assess health-related quality of life (HrQoL) among children living in a Schistosoma haematobium-endemic area in coastal Kenya. The PedsQL questionnaires were administered by interview to children aged 5-18 years (and their parents) in five villages spread across three districts. HrQoL (total score) was significantly lower in villages with high prevalence of S. haematobium (-4.0%, p<0.001) and among the lower socioeconomic quartiles (-2.0%, p<0.05). A greater effect was seen in the psychosocial scales as compared to the physical function scale. In moderate prevalence villages, detection of any parasite eggs in the urine was associated with a significant 2.1% (p<0.05) reduction in total score. The PedsQL reliabilities were generally high (Cronbach alphas β‰₯0.70), floor effects were acceptable, and identification of children from low socioeconomic standing was valid. CONCLUSIONS/SIGNIFICANCE: We conclude that exposure to urogenital schistosomiasis is associated with a 2-4% reduction in HrQoL. Further research is warranted to determine the reproducibility and responsiveness properties of QoL testing in relation to schistosomiasis. We anticipate that a case definition based on more sensitive parasitological diagnosis among younger children will better define the immediate and long-term HrQoL impact of Schistosoma infection

    A systematic review of the evidence for single stage and two stage revision of infected knee replacement

    Get PDF
    BACKGROUND: Periprosthetic infection about the knee is a devastating complication that may affect between 1% and 5% of knee replacement. With over 79 000 knee replacements being implanted each year in the UK, periprosthetic infection (PJI) is set to become an important burden of disease and cost to the healthcare economy. One of the important controversies in treatment of PJI is whether a single stage revision operation is superior to a two-stage procedure. This study sought to systematically evaluate the published evidence to determine which technique had lowest reinfection rates. METHODS: A systematic review of the literature was undertaken using the MEDLINE and EMBASE databases with the aim to identify existing studies that present the outcomes of each surgical technique. Reinfection rate was the primary outcome measure. Studies of specific subsets of patients such as resistant organisms were excluded. RESULTS: 63 studies were identified that met the inclusion criteria. The majority of which (58) were reports of two-stage revision. Reinfection rated varied between 0% and 41% in two-stage studies, and 0% and 11% in single stage studies. No clinical trials were identified and the majority of studies were observational studies. CONCLUSIONS: Evidence for both one-stage and two-stage revision is largely of low quality. The evidence basis for two-stage revision is significantly larger, and further work into direct comparison between the two techniques should be undertaken as a priority

    Extragalactic Radio Continuum Surveys and the Transformation of Radio Astronomy

    Full text link
    Next-generation radio surveys are about to transform radio astronomy by discovering and studying tens of millions of previously unknown radio sources. These surveys will provide new insights to understand the evolution of galaxies, measuring the evolution of the cosmic star formation rate, and rivalling traditional techniques in the measurement of fundamental cosmological parameters. By observing a new volume of observational parameter space, they are also likely to discover unexpected new phenomena. This review traces the evolution of extragalactic radio continuum surveys from the earliest days of radio astronomy to the present, and identifies the challenges that must be overcome to achieve this transformational change.Comment: To be published in Nature Astronomy 18 Sept 201

    The temporal reliability of serum estrogens, progesterone, gonadotropins, SHBG and urinary estrogen and progesterone metabolites in premenopausal women

    Get PDF
    BACKGROUND: There is little existing research to guide researchers in estimating the minimum number of measurement occasions required to obtain reliable estimates of serum estrogens, progesterone, gonadotropins, sex hormone-binding globulin (SHBG), and urinary estrogen and progesterone metabolites in premenopausal women. METHODS: Using data from a longitudinal study of 34 women with a mean age of 42.3 years (SD = 2.6), we calculated the minimum number of measurement occasions required to obtain reliable estimates of 12 analytes (8 in blood, 4 in urine). Five samples were obtained over 1 year: at baseline, and after 1, 3, 6, and 12 months. We also calculated the percent of true variance accounted for by a single measurement and intraclass correlation coefficients (ICC) between measurement occasions. RESULTS: Only 2 of the 12 analytes we examined, SHBG and estrone sulfate (E(1)S), could be adequately estimated by a single measurement using a minimum reliability standard of having the potential to account for 64% of true variance. Other analytes required from 2 to 12 occasions to account for 81% of the true variance, and 2 to 5 occasions to account for 64% of true variance. ICCs ranged from 0.33 for estradiol (E(2)) to 0.88 for SHBG. Percent of true variance accounted for by single measurements ranged from 29% for luteinizing hormone (LH) to 92% for SHBG. CONCLUSIONS: Experimental designs that take the natural variability of these analytes into account by obtaining measurements on a sufficient number of occasions will be rewarded with increased power and accuracy

    Parental perceptions of children's oral health: The Early Childhood Oral Health Impact Scale (ECOHIS)

    Get PDF
    BACKGROUND: Dental disease and treatment experience can negatively affect the oral health related quality of life (OHRQL) of preschool aged children and their caregivers. Currently no valid and reliable instrument is available to measure these negative influences in very young children. The objective of this research was to develop the Early Childhood Oral Health Impact Scale (ECOHIS) to measure the OHRQL of preschool children and their families. METHODS: Twenty-two health professionals evaluated a pool of 45 items that assess the impact of oral health problems on 6-14-year-old children and their families. The health professionals identified 36 items as relevant to preschool children. Thirty parents rated the importance of these 36 items to preschool children; 13 (9 child and 4 family) items were considered important. The 13-item ECOHIS was administered to 295 parents of 5-year-old children to assess construct validity and internal consistency reliability (using Cronbach's alpha). Test-retest reliability was evaluated among another sample of parents (N = 46) using the intraclass correlation coefficient (ICC). RESULTS: ECOHIS scores on the child and parent sections indicating worse quality of life were significantly associated with fair or poor parental ratings of their child's general and oral health, and the presence of dental disease in the child. Cronbach's alphas for the child and family sections were 0.91 and 0.95 respectively, and the ICC for test-retest reliability was 0.84. CONCLUSION: The ECOHIS performed well in assessing OHRQL among children and their families. Studies in other populations are needed to further establish the instrument's technical properties
    • …
    corecore