1,143 research outputs found
Recommended from our members
Long-term electrode behavior during treatment of arsenic contaminated groundwater by a pilot-scale iron electrocoagulation system.
Iron electrocoagulation (Fe-EC) is an effective technology to remove arsenic (As) from groundwater used for drinking. A commonly noted limitation of Fe-EC is fouling or passivation of electrode surfaces via rust accumulation over long-term use. In this study, we examined the effect of removing electrode surface layers on the performance of a large-scale (10,000 L/d capacity) Fe-EC plant in West Bengal, India. We also characterized the layers formed on the electrodes in active use for over 2 years at this plant. The electrode surfaces developed three distinct horizontal sections of layers that consisted of different minerals: calcite, Fe(III) precipitates and magnetite near the top, magnetite in the middle, and Fe(III) precipitates and magnetite near the bottom. The interior of all surface layers adjacent to the Fe(0) metal was dominated by magnetite. We determined the impact of surface layer removal by mechanical abrasion on Fe-EC performance by measuring solution composition (As, Fe, P, Si, Mn, Ca, pH, DO) and electrochemical parameters (total cell voltage and electrode interface potentials) during electrolysis. After electrode cleaning, the Fe concentration in the bulk solution increased substantially from 15.2 to 41.5 mg/L. This higher Fe concentration led to increased removal of a number of solutes. For As, the concentration reached below the 10 μg/L WHO MCL more rapidly and with less total Fe consumed (i.e. less electrical energy) after cleaning (128.4 μg/L As removed per kWh) compared to before cleaning (72.9 μg/L As removed per kWh). Similarly, the removal of P and Si improved after cleaning by 0.3 mg/L/kWh and 1.1 mg/L/kWh, respectively. Our results show that mechanically removing the surface layers that accumulate on electrodes over extended periods of Fe-EC operation can restore Fe-EC system efficiency (concentration of solute removed/kWh delivered). Since Fe release into the bulk solution substantially increased upon electrode cleaning, our results also suggest that routine electrode maintenance can ensure robust and reliable Fe-EC performance over year-long timescales
A model of dispersive transport across sharp interfaces between porous materials
Recent laboratory experiments on solute migration in composite porous columns
have shown an asymmetry in the solute arrival time upon reversal of the flow
direction, which is not explained by current paradigms of transport. In this
work, we propose a definition for the solute flux across sharp interfaces and
explore the underlying microscopic particle dynamics by applying Monte Carlo
simulation. Our results are consistent with previous experimental findings and
explain the observed transport asymmetry. An interpretation of the proposed
physical mechanism in terms of a flux rectification is also provided. The
approach is quite general and can be extended to other situations involving
transport across sharp interfaces.Comment: 4 pages, 4 figure
Recommended from our members
Rapid and Efficient Arsenic Removal by Iron Electrocoagulation Enabled with in Situ Generation of Hydrogen Peroxide.
Millions of people are exposed to toxic levels of dissolved arsenic in groundwater used for drinking. Iron electrocoagulation (FeEC) has been demonstrated as an effective technology to remove arsenic at an affordable price. However, FeEC requires long operating times (∼hours) to remove dissolved arsenic due to inherent kinetics limitations. Air cathode Assisted Iron Electrocoagulation (ACAIE) overcomes this limitation by cathodically generating H2O2 in situ. In ACAIE operation, rapid oxidation of Fe(II) and complete oxidation and removal of As(III) are achieved. We compare FeEC and ACAIE for removing As(III) from an initial concentration of 1464 μg/L, aiming for a final concentration of less than 4 μg/L. We demonstrate that at short electrolysis times (0.5 min), i.e., high charge dosage rates (1200 C/L/min), ACAIE consistently outperformed FeEC in bringing arsenic levels to less than WHO-MCL of 10 μg/L. Using XRD and XAS data, we conclusively show that poor arsenic removal in FeEC arises from incomplete As(III) oxidation, ineffective Fe(II) oxidation and the formation of Fe(II-III) (hydr)oxides at short electrolysis times (<20 min). Finally, we report successful ACAIE performance (retention time 19 s) in removing dissolved arsenic from contaminated groundwater in rural California
Factors affecting the Faradaic efficiency of Fe(0) electrocoagulation
Electrocoagulation (EC) using Fe(0) electrodes is a low cost water treatment technology that relies on efficient production of Fe(II) from the electrolytic dissolution of Fe(0) electrodes (i.e. a high Faradaic efficiency). However, the (electro)chemical factors that favor Fe(0) oxidation rather than O2 evolution during Fe(0) EC have not been identified. In this study, we combined electrochemical methods, electron microscopy and Fe measurements to systematically examine the interdependent effects of current density (i), anodic interface potential (EA) and solution chemistry on the Faradaic efficiency. We found that Fe(0) oxidation was favored (Faradaic efficiency >0.85) in chloride and bromide solutions at all i, whereas carbonate, phosphate, citrate, and nitrate solutions lead to Faradaic efficiencies <0.1. The anodic reaction (i.e. Fe(0) oxidation or O2 evolution) only depended on i in the sulfate and formate solutions. Experiments in binary-anion solutions revealed that molar ratios of [HCO3−]/[Cl−] near 100 and [NO3−]/[Cl−] near 20 separated the electrochemical domains of Fe(0) oxidation and O2 evolution in the EC system. These molar ratios were supported by experiments in synthetic groundwater solutions. We also found that the EA vs i curves for solutions with poor Faradaic efficiency overlapped but were situated 2–4 V vs Ag/AgCl higher than those of solutions with high Faradaic efficiency. Therefore, the position of the EA vs i curve, rather than the EA alone, can be used to determine unambiguously the reaction occurring on the Fe(0) anode during EC treatment
- …