49 research outputs found

    Fully covered self-expanding metal stents placed temporarily in the bile duct: safety profile and histologic classification in a porcine model

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fully covered Self-Expanding metal stents (FCSEMS) have been shown efficacious in palliating malignant biliary obstructions. There is little data analyzing mucosal response to their temporary placement in the bile duct.</p> <p>Methods</p> <p>Ten mini pigs underwent endoscopic placement of a FCSEMS (Wallflex, Boston Scientific). FCSEMS were kept in place for three months. At the end of the 3 months, FCSEMS were removed endoscopically. Five pigs were euthanized and their bile ducts harvested. The other five were kept alive for another month post removal. A single pathologist, created a scoring system (to determine degree of inflammation, fibrosis, and epithelial injury), examined all specimens in a blinded fashion.</p> <p>Results</p> <p>Four FCSEMS spontaneously migrated in the duodenum. On post mortem examination, mild mucosal thickness was noted in three bile duct specimens while superficial inflammation of the bile duct was noted in five animals. Histologic examination of the bile duct revealed focal acute inflammation in both groups. For the 5 animals euthanized immediately after stent removal, there was a tendency to have superficial mucosal erosion and fibrosis. In contrast, increased chronic inflammation was more commonly seen in the animals 1 month post stent removal, with all animals in this group showing moderate degrees of mononuclear inflammatory cell mucosal infiltrates. No severe inflammatory or fibrotic duct injury was observed in any of the study animals, with degree of injury graded as mild to moderate.</p> <p>Conclusion</p> <p>FCSEMS appear to induce minimal tissue overgrowth or fibrosis post placement. Ease of removability and no significant histologic injury are advantages noted with FCSEMS., however, further studies are needed to evaluate treating benign biliary strictures with FCSEMS in humans.</p

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 1: The LBNF and DUNE Projects

    Get PDF
    This document presents the Conceptual Design Report (CDR) put forward by an international neutrino community to pursue the Deep Underground Neutrino Experiment at the Long-Baseline Neutrino Facility (LBNF/DUNE), a groundbreaking science experiment for long-baseline neutrino oscillation studies and for neutrino astrophysics and nucleon decay searches. The DUNE far detector will be a very large modular liquid argon time-projection chamber (LArTPC) located deep underground, coupled to the LBNF multi-megawatt wide-band neutrino beam. DUNE will also have a high-resolution and high-precision near detector

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report, Volume 4 The DUNE Detectors at LBNF

    Get PDF
    A description of the proposed detector(s) for DUNE at LBN

    The Single-Phase ProtoDUNE Technical Design Report

    Get PDF
    ProtoDUNE-SP is the single-phase DUNE Far Detector prototype that is under construction and will be operated at the CERN Neutrino Platform (NP) starting in 2018. ProtoDUNE-SP, a crucial part of the DUNE effort towards the construction of the first DUNE 10-kt fiducial mass far detector module (17 kt total LAr mass), is a significant experiment in its own right. With a total liquid argon (LAr) mass of 0.77 kt, it represents the largest monolithic single-phase LArTPC detector to be built to date. It's technical design is given in this report
    corecore