24 research outputs found

    3066 consecutive Gamma Nails. 12 years experience at a single centre

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Fixation of trochanteric hip fractures using the Gamma Nail has been performed since 1988 and is today well established and wide-spread. However, a number of reports have raised serious concerns about the implant's complication rate. The main focus has been the increased risk of a subsequent femoral shaft fracture and some authors have argued against its use despite other obvious advantages, when this implant is employed.</p> <p>Through access to a uniquely large patient data base available, which is available for analysis of trochanteric fractures; we have been able to evaluate the performance of the Gamma Nail over a twelve year period.</p> <p>Methods</p> <p>3066 consecutive patients were treated for trochanteric fractures using Gamma Nails between 1990 and 2002 at the Centre de Traumatologie et de l'Orthopedie (CTO), Strasbourg, France. These patients were retrospectively analysed. Information on epidemiological data, intra- and postoperative complications and patients' outcome was retrieved from patient notes. All available radiographs were assessed by a single reviewer (AJB).</p> <p>Results</p> <p>The results showed a low complication rate with the use of the Gamma Nail. There were 137 (4.5%) intraoperative fracture-related complications. Moreover 189 (6.2%) complications were detected postoperatively and during follow-up. Cut-out of the lag screw from the femoral head was the most frequent mechanical complication (57 patients, 1.85%), whereas a postoperative femoral shaft fracture occurred in 19 patients (0.6%). Other complications, such as infection, delayed healing/non-union, avascular femoral head necrosis and distal locking problems occurred in 113 patients (3.7%).</p> <p>Conclusions</p> <p>The use of the Gamma Nail in trochanteric hip fractures is a safe method with a low complication rate. In particular, a low rate of femoral shaft fractures was reported. The low complication rate reported in this series can probably be explained by strict adherence to a proper surgical technique.</p

    <i>In Silico</i> Profiling of Clinical Phenotypes for Human Targets Using Adverse Event Data

    No full text
    We present a novel approach for the molecular transformation and analysis of patient clinical phenotypes. Building on the fact that drugs perturb the function of targets/genes, we integrated data from 8.2 million clinical reports detailing drug-induced side effects with the molecular world of drug-target information. Using this dataset, we extracted 1.8 million associations of clinical phenotypes to 770 human drug-targets. This collection is perhaps the largest phenotypic profiling reference of human targets to-date, and unique in that it enables rapid development of testable molecular hypotheses directly from human-specific information. We also present validation results demonstrating analytical utilities of the approach, including drug safety prediction, and the design of novel combination therapies. Challenging the long-standing notion that molecular perturbation studies cannot be performed in humans, our data allows researchers to capitalize on the vast tomes of clinical information available throughout the healthcare system

    Stabilisation d'une induction magnétique (0 à 1 000 gauss) par effet Hall

    No full text
    A magnetic field stabilizer using the Hall effect has been constructed. It is separated into two parts : — first a stabilization using the Hall effect with D.C. supply ; — second a stabilization using the Hall effect with A.C supply. The stability obtained is 10—3 at a low cost.Une stabilisation de l'induction d'un électro-aimant utilisant l'effet Hall a été réalisé. Elle se décompose en deux parties : — une chaîne par effet Hall en courant continu ; — puis une deuxième chaîne par effet Hall en courant alternatif. La stabilité obtenue est de 10—3, à peu de frais
    corecore