77 research outputs found

    Prevalence of transmitted nucleoside analogue-resistant HIV-1 strains and pre-existing mutations in pol reverse transcriptase and protease region : outcome after treatment in recently infected individuals

    Get PDF
    We retrospectively studied 38 Italian recently HIV-1-infected subjects who seroconverted from 1994 to 1997 to investigate: (i) the prevalence of nucleoside reverse transcriptase inhibitors (NRTI)-related mutations at primary infection; (ii) the proportion of naturally occurring mutations in reverse transcriptase (RT) and protease regions of patients naive for non-nucleoside RT inhibitors (NNRTIs) and protease inhibitors (PIs); (iii) the drug-susceptibility to NRTIs and PIs in subjects with NRTI- and/or PI-related mutations; and (iv) the outcome of seroconverters treated with various NRTIs or NRTI/PI regimens. Baseline HIV-1 plasma viraemia and absolute CD4 count at baseline could not be used to distinguish patients with NRTI- and/or PI-related pre-existing mutations from those with wild-type virus (P = 0.693 and P = 0.542, respectively). The frequency of zidovudine-related mutations was 21% in the study period. The response to treatment was not significantly different in subjects with or without genotypic zidovudine-related mutations at primary infection (P = 0.744 for HIV-1 RNA and P = 0.102 for CD4 cells). Some natural variation (2.6%) was present within regions 98-108 and 179-190 of RT involved in NNRTI resistance. The high natural polymorphism in the protease region present in our patients was similar to that reported by others. In our study some PI-associated substitutions, thought to be compensatory in protease enzymatic function, could confer intermediate to high PI-resistance. As discrepancies between genotypic and phenotypic results may exist in recent seroconverters, our data suggest that the role of transmitted NRTI- and PI-resistant variants remain to be fully elucidated in vivo

    Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system

    Get PDF
    Background: To assess the accuracy of fractionated stereotactic radiotherapy (FSRT) using a stereotactic mask fixation system. Patients and Methods: Sixteen patients treated with FSRT were involved in the study. A commercial stereotactic mask fixation system (BrainLAB AG) was used for patient immobilization. Serial CT scans obtained before and during FSRT were used to assess the accuracy of patient immobilization by comparing the isocenter position. Daily portal imaging were acquired to establish day to day patient position variation. Displacement errors along the different directions were calculated as combination of systematic and random errors. Results: The mean isocenter displacements based on localization and verification CT imaging were 0.1 mm (SD 0.3 mm) in the lateral direction, 0.1 mm (SD 0.4 mm) in the anteroposterior, and 0.3 mm (SD 0.4 mm) in craniocaudal direction. The mean 3D displacement was 0.5 mm (SD 0.4 mm), being maximum 1.4 mm. No significant differences were found during the treatment (P = 0.4). The overall isocenter displacement as calculated by 456 anterior and lateral portal images were 0.3 mm (SD 0.9 mm) in the mediolateral direction, -0.2 mm (SD 1 mm) in the anteroposterior direction, and 0.2 mm (SD 1.1 mm) in the craniocaudal direction. The largest displacement of 2.7 mm was seen in the cranio-caudal direction, with 95% of displacements < 2 mm in any direction. Conclusions: The results indicate that the setup error of the presented mask system evaluated by CT verification scans and portal imaging are minimal. Reproducibility of the isocenter position is in the best range of positioning reproducibility reported for other stereotactic systems

    Comparison of reflector antenna measurements and simulations

    Get PDF
    In antenna measurement, well-established procedures are consolidated to determine the associated measurement uncertainty for a given antenna and measurements scenario [1-2]. Similar criteria for establishing uncertainties in numerical modeling of the same antenna are still to be established. In this paper, we investigate the achievable agreement between antenna measurement and simulation when external error sources are minimized. The test object, is a reflector fed by a wideband dual ridge horn (SR40-A and SH4000) manufactured by MVG. This highly stable reference antenna has been selected to minimize uncertainty related to finite manufacturing and material parameter accuracy. Two frequencies, 10.7GHz and 18GHz have been selected for detailed investigation. The antenna has been measured by several measurement facilities (spherical, cylindrical and planar near field ranges) across Europe in the ? ? ? ? ? ? ? ? activity. The purpose of this intercomparison campaign is the comparison of the different antenna measurement facilities, throughout Europe, considering measurement procedures and uncertainty estimates. The antenna has been simulated using a full CAD model, in step compatible format and using different numerical methods from different software vendor

    Salicylsäure

    No full text
    corecore