1,695 research outputs found

    Reactions to uncertainty and the accuracy of diagnostic mammography.

    Get PDF
    BackgroundReactions to uncertainty in clinical medicine can affect decision making.ObjectiveTo assess the extent to which radiologists' reactions to uncertainty influence diagnostic mammography interpretation.DesignCross-sectional responses to a mailed survey assessed reactions to uncertainty using a well-validated instrument. Responses were linked to radiologists' diagnostic mammography interpretive performance obtained from three regional mammography registries.ParticipantsOne hundred thirty-two radiologists from New Hampshire, Colorado, and Washington.MeasurementMean scores and either standard errors or confidence intervals were used to assess physicians' reactions to uncertainty. Multivariable logistic regression models were fit via generalized estimating equations to assess the impact of uncertainty on diagnostic mammography interpretive performance while adjusting for potential confounders.ResultsWhen examining radiologists' interpretation of additional diagnostic mammograms (those after screening mammograms that detected abnormalities), a 5-point increase in the reactions to uncertainty score was associated with a 17% higher odds of having a positive mammogram given cancer was diagnosed during follow-up (sensitivity), a 6% lower odds of a negative mammogram given no cancer (specificity), a 4% lower odds (not significant) of a cancer diagnosis given a positive mammogram (positive predictive value [PPV]), and a 5% higher odds of having a positive mammogram (abnormal interpretation).ConclusionMammograms interpreted by radiologists who have more discomfort with uncertainty have higher likelihood of being recalled

    Search for axion-like particles using a variable baseline photon regeneration technique

    Full text link
    We report the first results of the GammeV experiment, a search for milli-eV mass particles with axion-like couplings to two photons. The search is performed using a "light shining through a wall" technique where incident photons oscillate into new weakly interacting particles that are able to pass through the wall and subsequently regenerate back into detectable photons. The oscillation baseline of the apparatus is variable, thus allowing probes of different values of particle mass. We find no excess of events above background and are able to constrain the two-photon couplings of possible new scalar (pseudoscalar) particles to be less than 3.1x10^{-7} GeV^{-1} (3.5x10^{-7} GeV^{-1}) in the limit of massless particles.Comment: 5 pages, 4 figures. This is the version accepted by PRL and includes updated limit

    On Convergence of the Inexact Rayleigh Quotient Iteration with the Lanczos Method Used for Solving Linear Systems

    Full text link
    For the Hermitian inexact Rayleigh quotient iteration (RQI), the author has established new local general convergence results, independent of iterative solvers for inner linear systems. The theory shows that the method locally converges quadratically under a new condition, called the uniform positiveness condition. In this paper we first consider the local convergence of the inexact RQI with the unpreconditioned Lanczos method for the linear systems. Some attractive properties are derived for the residuals, whose norms are Οk+1\xi_{k+1}'s, of the linear systems obtained by the Lanczos method. Based on them and the new general convergence results, we make a refined analysis and establish new local convergence results. It is proved that the inexact RQI with Lanczos converges quadratically provided that Οk+1≀Ο\xi_{k+1}\leq\xi with a constant Ο≄1\xi\geq 1. The method is guaranteed to converge linearly provided that Οk+1\xi_{k+1} is bounded by a small multiple of the reciprocal of the residual norm ∄rk∄\|r_k\| of the current approximate eigenpair. The results are fundamentally different from the existing convergence results that always require Οk+1<1\xi_{k+1}<1, and they have a strong impact on effective implementations of the method. We extend the new theory to the inexact RQI with a tuned preconditioned Lanczos for the linear systems. Based on the new theory, we can design practical criteria to control Οk+1\xi_{k+1} to achieve quadratic convergence and implement the method more effectively than ever before. Numerical experiments confirm our theory.Comment: 20 pages, 8 figures. arXiv admin note: text overlap with arXiv:0906.223

    Advances in multispectral and hyperspectral imaging for archaeology and art conservation

    Get PDF
    Multispectral imaging has been applied to the field of art conservation and art history since the early 1990s. It is attractive as a noninvasive imaging technique because it is fast and hence capable of imaging large areas of an object giving both spatial and spectral information. This paper gives an overview of the different instrumental designs, image processing techniques and various applications of multispectral and hyperspectral imaging to art conservation, art history and archaeology. Recent advances in the development of remote and versatile multispectral and hyperspectral imaging as well as techniques in pigment identification will be presented. Future prospects including combination of spectral imaging with other noninvasive imaging and analytical techniques will be discussed

    Electron neutrino tagging through tertiary lepton detection

    Get PDF
    We discuss an experimental technique aimed at tagging electron neutrinos in multi-GeV artificial sources on an event-by-event basis. It exploits in a novel manner calorimetric and tracking technologies developed in the framework of the LHC experiments and of rare kaon decay searches. The setup is suited for slow-extraction, moderate power beams and it is based on an instrumented decay tunnel equipped with tagging units that intercept secondary and tertiary leptons from the bulk of undecayed \pi^+ and protons. We show that the taggers are able to reduce the \nue contamination originating from K_e3 decays by about one order of magnitude. Only a limited suppression (~60%) is achieved for \nue produced by the decay-in-flight of muons; for low beam powers, similar performance as for K_e3 can be reached supplementing the tagging system with an instrumented beam dump.Comment: 19 pages, 7 figures; minor changes, version to appear in EPJ
    • 

    corecore