131 research outputs found

    Application of COMPOCHIP Microarray to Investigate the Bacterial Communities of Different Composts

    Get PDF
    A microarray spotted with 369 different 16S rRNA gene probes specific to microorganisms involved in the degradation process of organic waste during composting was developed. The microarray was tested with pure cultures, and of the 30,258 individual probe-target hybridization reactions performed, there were only 188 false positive (0.62%) and 22 false negative signals (0.07%). Labeled target DNA was prepared by polymerase chain reaction amplification of 16S rRNA genes using a Cy5-labeled universal bacterial forward primer and a universal reverse primer. The COMPOCHIP microarray was applied to three different compost types (green compost, manure mix compost, and anaerobic digestate compost) of different maturity (2, 8, and 16 weeks), and differences in the microorganisms in the three compost types and maturity stages were observed. Multivariate analysis showed that the bacterial composition of the three composts was different at the beginning of the composting process and became more similar upon maturation. Certain probes (targeting Sphingobacterium, Actinomyces, Xylella/Xanthomonas/ Stenotrophomonas, Microbacterium, Verrucomicrobia, Planctomycetes, Low G + C and Alphaproteobacteria) were more influential in discriminating between different composts. Results from denaturing gradient gel electrophoresis supported those of microarray analysis. This study showed that the COMPOCHIP array is a suitable tool to study bacterial communities in composts

    TALEN-mediated editing of the mouse Y chromosome

    Get PDF
    The functional study of Y chromosome genes has been hindered by a lack of mouse models with specific Y chromosome mutations. We used transcription activator-like effector nuclease (TALEN)-mediated gene editing in mouse embryonic stem cells (mESCs) to produce mice with targeted gene disruptions and insertions in two Y-linked genes—Sry and Uty. TALEN-mediated gene editing is a useful tool for dissecting the biology of the Y chromosome.National Institutes of Health (U.S.) (US NIH grant R01-HG000257)National Institutes of Health (U.S.) (US NIH grant R01-CA084198)National Institutes of Health (U.S.) (US NIH grant R37-HD045022)Croucher Foundation (Scholarship)Howard Hughes Medical Institute (Investigator

    Study of the decay K+→π+π−π+ÎłK^{+}\to\pi^{+}\pi^{-}\pi^{+}\gamma in the OKA experiment

    Full text link
    A high statistics data sample of the decays of K+K^+ mesons to three charged particles was accumulated by the OKA experiment in 2012 and 2013. This allowed to select a clean sample of about 450 events with K+→π+π−π+ÎłK^{+}\to\pi^{+}\pi^{-}\pi^{+}\gamma decays with the energy of the photon in the kaon rest frame greater than 30 MeV. The measured branching fraction of the K+→π+π−π+ÎłK^{+}\to\pi^{+}\pi^{-}\pi^{+}\gamma, with Eγ∗E_{\gamma}^{*} > 30 MeV is (0.71±0.05)×10−5(0.71 \pm 0.05) \times 10^{-5}. The measured energy spectrum of the decay photon is compared with the prediction of the chiral perturbation theory to O(p4)(p^{4}). A search for an up-down asymmetry of the photon with respect to the hadronic system decay plane is also performed.Comment: 9 pages, 7 figures, 1 tabl

    Rapid and simultaneous detection of human hepatitis B virus and hepatitis C virus antibodies based on a protein chip assay using nano-gold immunological amplification and silver staining method

    Get PDF
    BACKGROUND: Viral hepatitis due to hepatitis B virus and hepatitis C virus are major public health problems all over the world. Traditional detection methods including polymerase chain reaction (PCR)-based assays and enzyme-linked immunosorbent assays (ELISA) are expensive and time-consuming. In our assay, a protein chip assay using Nano-gold Immunological Amplification and Silver Staining (NIASS) method was applied to detect HBV and HCV antibodies rapidly and simultaneously. METHODS: Chemically modified glass slides were used as solid supports (named chip), on which several antigens, including HBsAg, HBeAg, HBcAg and HCVAg (a mixture of NS3, NS5 and core antigens) were immobilized respectively. Colloidal nano-gold labelled staphylococcal protein A (SPA) was used as an indicator and immunogold silver staining enhancement technique was applied to amplify the detection signals, producing black image on array spots, which were visible with naked eyes. To determine the detection limit of the protein chip assay, a set of model arrays in which human IgG was spotted were structured and the model arrays were incubated with different concentrations of anti-IgG. A total of 305 serum samples previously characterized with commercial ELISA were divided into 4 groups and tested in this assay. RESULTS: We prepared mono-dispersed, spherical nano-gold particles with an average diameter of 15 ± 2 nm. Colloidal nano-gold-SPA particles observed by TEM were well-distributed, maintaining uniform and stable. The optimum silver enhancement time ranged from 8 to 12 minutes. In our assay, the protein chips could detect serum antibodies against HBsAg, HBeAg, HBcAg and HCVAg with the absence of the cross reaction. In the model arrays, the anti-IgG as low as 3 ng/ml could be detected. The data for comparing the protein chip assay with ELISA indicated that no distinct difference (P > 0.05) existed between the results determined by our assay and ELISA respectively. CONCLUSION: Results showed that our assay can be applied with serology for the detection of HBV and HCV antibodies rapidly and simultaneously in clinical detection

    LHCb calorimeters: Technical Design Report

    Get PDF

    LHCb magnet: Technical Design Report

    Get PDF

    LHCb RICH: Technical Design Report

    Get PDF
    • 

    corecore