5,533 research outputs found
The new servo-spill power converter of the CERN SPS machine
The so-called servo-spill system of the SPS machine requires a very specific power converter to be used as the power actuator of the system. Due to this particular function, the main performance required, for this power converter, is an unusual large signal current bandwidth of up to 1.5 kHz. The procurement is based on a similar industrial product using switch mode technology. This paper describes the main power part as well as the control approach chosen to fulfil the specific requirements of this power converter. Final operational results are also presented
Gemini Planet Imager Observational Calibrations III: Empirical Measurement Methods and Applications of High-Resolution Microlens PSFs
The newly commissioned Gemini Planet Imager (GPI) combines extreme adaptive
optics, an advanced coronagraph, precision wavefront control and a
lenslet-based integral field spectrograph (IFS) to measure the spectra of young
extrasolar giant planets between 0.9-2.5 um. Each GPI detector image, when in
spectral model, consists of ~37,000 microspectra which are under or critically
sampled in the spatial direction. This paper demonstrates how to obtain
high-resolution microlens PSFs and discusses their use in enhancing the
wavelength calibration, flexure compensation and spectral extraction. This
method is generally applicable to any lenslet-based integral field spectrograph
including proposed future instrument concepts for space missions.Comment: 10 pages, 6 figures. Proceedings of the SPIE, 9147-282 v2: reference
adde
Comment on "On the -Anomaly in Betaine Calcium Chloride Dihydrate"
Recently, Hlinka and Ishibashi [J. Phys. Soc. Jpn. 67, 495 (1998)] discussed
the -anomaly in betaine calcium chloride dihydrate (BCCD) in a Landau-type
approach. We comment on the shortcomings of this approach and discuss the
-anomaly in the framework of a microscopical pseudo spin model based on a
realistic description of BCCD in terms of symmetry-adapted local modes.Comment: 2 pages, RevTex, submitted to J. Phys. Soc. Jp
Fermi Edge Singularities in Transport through Quantum Dots
We study the Fermi-edge singularity appearing in the current-voltage
characteristics for resonant tunneling through a localized level at finite
temperature. An explicit expression for the current at low temperature and near
the threshold for the tunneling process is presented which allows to coalesce
data taken at different temperatures to a single curve. Based on this scaling
function for the current we analyze experimental data from a GaAs-AlAs-GaAs
tunneling device with embedded InAs quantum dots obtained at low temperatures
in high magnetic fields.Comment: 12 pages, 5 figure
The electromagnetic calorimeter of the AMS-02 experiment
The electromagnetic calorimeter (ECAL) of the AMS-02 experiment is a
3-dimensional sampling calorimeter, made of lead and scintillating fibers. The
detector allows for a high granularity, with 18 samplings in the longitudinal
direction, and 72 sampling in the lateral direction. The ECAL primary goal is
to measure the energy of cosmic rays up to few TeV, however, thanks to the fine
grained structure, it can also provide the separation of positrons from
protons, in the GeV to TeV region. A direct measurement of high energy photons
with accurate energy and direction determination can also be provided.Comment: Proceedings of SF2A conference 201
Search for cool giant exoplanets around young and nearby stars - VLT/NaCo near-infrared phase-coronagraphic and differential imaging
[Abridged] Context. Spectral differential imaging (SDI) is part of the
observing strategy of current and future high-contrast imaging instruments. It
aims to reduce the stellar speckles that prevent the detection of cool planets
by using in/out methane-band images. It attenuates the signature of off-axis
companions to the star, such as angular differential imaging (ADI). However,
this attenuation depends on the spectral properties of the low-mass companions
we are searching for. The implications of this particularity on estimating the
detection limits have been poorly explored so far. Aims. We perform an imaging
survey to search for cool (Teff<1000-1300 K) giant planets at separations as
close as 5-10 AU. We also aim to assess the sensitivity limits in SDI data
taking the photometric bias into account. This will lead to a better view of
the SDI performance. Methods. We observed a selected sample of 16 stars (age <
200 Myr, d < 25 pc) with the phase-mask coronagraph, SDI, and ADI modes of
VLT/NaCo. Results. We do not detect any companions. As for the sensitivity
limits, we argue that the SDI residual noise cannot be converted into mass
limits because it represents a differential flux, unlike the case of
single-band images. This results in degeneracies for the mass limits, which may
be removed with the use of single-band constraints. We instead employ a method
of directly determining the mass limits. The survey is sensitive to cool giant
planets beyond 10 AU for 65% and 30 AU for 100% of the sample. Conclusions. For
close-in separations, the optimal regime for SDI corresponds to SDI flux ratios
>2. According to the BT-Settl model, this translates into Teff<800 K. The
methods described here can be applied to the data interpretation of SPHERE. We
expect better performance with the dual-band imager IRDIS, thanks to more
suitable filter characteristics and better image quality.Comment: 19 pages, 16 figures, accepted for publication in A&A, version
including language editin
Measurement of the electron drift velocity for directional dark matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection. It requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence a way to avoid bias in the 3D track reconstruction. We present a
dedicated method for the measurement of the electron drift velocity with the
MIMAC detector. It is tested on two gas mixtures : and . We also show that adding allows us to lower the
electron drift velocity while keeping almost the same Fluorine content of the
gas mixture.Comment: Proceedings of the 4th international conference on Directional
Detection of Dark Matter (CYGNUS 2013), 10-12 June 2013, Toyama, Japa
GEANT: detector description and simulation tool
As the scale and complexity of High Energy Physics experiments increase, simulation studies require more and more care and become essential to design and optimise the detectors, develop and test the reconstruction and analysis programs, and interpret the experimental data. GEANT is a system of detector description and simulation tools that help physicists in such studies
In situ measurement of the electron drift velocity for upcoming directional Dark Matter detectors
Three-dimensional track reconstruction is a key issue for directional Dark
Matter detection and it requires a precise knowledge of the electron drift
velocity. Magboltz simulations are known to give a good evaluation of this
parameter. However, large TPC operated underground on long time scale may be
characterized by an effective electron drift velocity that may differ from the
value evaluated by simulation. In situ measurement of this key parameter is
hence needed as it is a way to avoid bias in the 3D track reconstruction. We
present a dedicated method for the measurement of the electron drift velocity
with the MIMAC detector. It is tested on two gas mixtures: CF4 and CF4 + CHF3.
The latter has been chosen for the MIMAC detector as we expect that adding CHF3
to pure CF4 will lower the electron drift velocity. This is a key point for
directional Dark Matter as the track sampling along the drift field will be
improved while keeping almost the same Fluorine content of the gas mixture. We
show that the drift velocity at 50 mbar is reduced by a factor of about 5 when
adding 30% of CHF3.Comment: 19 pages, 14 figures. Minor corrections, matches published version in
JINS
- …
