1,521 research outputs found
The Low Energy Tagger for the KLOE-2 experiment
The KLOE experiment at the upgraded DAFNE e+e- collider in Frascati (KLOE-2)
is going to start a new data taking at the beginning of 2010 with its detector
upgraded with a tagging system for the identification of gamma-gamma
interactions. The tagging stations for low-energy e+e- will consist in two
calorimeters The calorimeter used to detect low-energy e+e- will be placed
between the beam-pipe outer support structure and the inner wall of the KLOE
drift chamber. This calorimeter will be made of LYSO crystals readout by
Silicon Photomultipliers, to achieve an energy resolution better than 8% at 200
MeV.Comment: 4 pages, 5 figures, in the proceedings of "Frontier detectors for
frontier physics", isola d'Elba, Italy, May 200
Níveis de metano e perdas energéticas em bovinos de corte, suplementados ou não, em pastagem de capim mombaça (Panicum maximum cv. Mombaça).
Objetivou-se avaliar o impacto da suplementação protéico-energética na emissão de metano (CH4) de novilhos, durante a recria, em pastagem de capim-mombaça. Os tratamentos avaliados foram: T0 ? Apenas suplementação mineral; T1 ? Suplementação protéico-energética. Utilizou-se a técnica do gás traçador interno hexafluoreto de enxofre (SF6) para estimar a emissão diária de CH4. Foram utilizados 20 animais, sendo dez de cada tratamento, em dois ensaios, com medição de CH4 em cinco dias consecutivos. Na análise estatística dos dados de emissão de CH4 , utilizou-se a metodologia de modelos mistos para medidas repetidas do SAS. Os animais foram também avaliados quanto à eficiência de utilização do alimento, utilizando-se como critério o consumo alimentar residual (CAR). Animais suplementados e não suplementados não diferiram (P>0,05) quanto à produção diária de metano e quanto à perda total diária de energia na forma de CH4. Entretanto, quando a perda de energia foi expressa em g/kg de matéria seca consumida (21,51 vs. 29,76 g/kg) e como porcentagem da energia bruta (EB) ingerida (6,36 versus 8,59 %), os animais suplementados tiveram menores perdas (P0,05) quanto aos níveis de emissão de metano (total ou por kg de matéria seca ? MS ingerida). Assim, conclui-se que: a suplementação com concentrado age de forma efetiva na mitigação da emissão de metano; diferenças no CAR não podem ser atribuídas a diferenças nos níveis de emissão de metano
Precision Measurement of KS Meson Lifetime with the KLOE detector
Using a large sample of pure, slow, short lived K0 mesons collected with KLOE
detector at DaFne, we have measured the KS lifetime. From a fit to the proper
time distribution we find tau = (89.562 +- 0.029_stat +- 0.043_syst) ps. This
is the most precise measurement today in good agreement with the world average
derived from previous measurements. We observe no dependence of the lifetime on
the direction of the Ks.Comment: 5 pages, 7 figure
A global fit to determine the pseudoscalar mixing angle and the gluonium content of the eta' meson
We update the values of the eta-eta' mixing angle and of the eta' gluonium
content by fitting our measurement R_phi = BR(phi to eta' gamma)/ BR(phi to eta
gamma) together with several vector meson radiative decays to pseudoscalars (V
to P gamma), pseudoscalar mesons radiative decays to vectors (P to V gamma) and
the eta' to gamma gamma, pi^0 to gamma gamma widths. From the fit we extract a
gluonium fraction of Z^2_G = 0.12 +- 0.04, the pseudoscalar mixing angle psi_P
= (40.4 +- 0.6) degree and the phi-omega mixing angle psi_V = (3.32 +- 0.09)
degree. Z^2_G and psi_P are fairly consistent with those previously published.
We also evaluate the impact on the eta' gluonium content determination of
future experimental improvements of the eta' branching ratios and decay width.Comment: 13 pages, 7 figures to submit to JHE
Measurement of the neutron detection efficiency of a 80% absorber - 20% scintillating fibers calorimeter
The neutron detection efficiency of a sampling calorimeter made of 1 mm
diameter scintillating fibers embedded in a lead/bismuth structure has been
measured at the neutron beam of the The Svedberg Laboratory at Uppsala. A
significant enhancement of the detection efficiency with respect to a bulk
organic scintillator detector with the same thickness is observed.Comment: 10 pages, 7 figure
Charged kaon lifetime at KLOE
Preliminary result on the charged kaon lifetime, obtained by the KLOE
experiment operating at DANE, the Frascati -factory, is presentedComment: 3 pages, 3 figures, to appear in the proceedings of 42nd Rencontres
de Moriond on Electroweak Interactions and Unified Theories, La Thuile, Aosta
Valley, Italy, 10-17 Mar 200
Prenatal tobacco smoke exposure increases hospitalizations for bronchiolitis in infants
BACKGROUND: Tobacco smoke exposure (TSE) is a worldwide health problem and it is considered a risk factor for pregnant women's and children's health, particularly for respiratory morbidity during the first year of life. Few significant birth cohort studies on the effect of prenatal TSE via passive and active maternal smoking on the development of severe bronchiolitis in early childhood have been carried out worldwide. METHODS: From November 2009 to December 2012, newborns born at ≥ 33 weeks of gestational age (wGA) were recruited in a longitudinal multi-center cohort study in Italy to investigate the effects of prenatal and postnatal TSE, among other risk factors, on bronchiolitis hospitalization and/or death during the first year of life. RESULTS: Two thousand two hundred ten newborns enrolled at birth were followed-up during their first year of life. Of these, 120 (5.4%) were hospitalized for bronchiolitis. No enrolled infants died during the study period. Prenatal passive TSE and maternal active smoking of more than 15 cigarettes/daily are associated to a significant increase of the risk of offspring children hospitalization for bronchiolitis, with an adjHR of 3.5 (CI 1.5-8.1) and of 1.7 (CI 1.1-2.6) respectively. CONCLUSIONS: These results confirm the detrimental effects of passive TSE and active heavy smoke during pregnancy for infants' respiratory health, since the exposure significantly increases the risk of hospitalization for bronchiolitis in the first year of lif
Determination of CP and CPT violation parameters in the neutral kaon system using the Bell-Steinberger relation and data from the KLOE experiment
We present an improved determination of the CP and CPT violation parameters
Re(epsilon) and Im(delta) based on the unitarity condition (Bell-Steinberger
relation) and on recent results from the KLOE experiment. We find Re(epsilon) =
(159.6 \pm 1.3)10^-5 and Im(delta) = (0.4 \pm 2.1)10^-5, consistent with no CPT
violation.Comment: Submitted to JHE
- …
