446 research outputs found

    Porphyrin-containing polyimide films deposited by high vacuum co-evaporation

    Get PDF
    Abstract Thin films of porphyrin-containing polyimide were produced by high vacuum co-evaporation of 4,4′-hexafluoroisopropylidene diphthalic anhydride (6FDA), 3,3′-diaminodiphenyl sulfone (DDS) and 5,10,15,20 meso-tetraphenyl porphyrin (TPP). The films were characterized by FT-IR analysis, optical absorption and emission spectroscopy. FT-IR analysis shows that the film matrix is comprised of only unreacted monomers. The conversion of monomers to polyamic acid and the following condensation to polyimide were studied by curing the samples at temperatures up to 240 °C. The amount of polyamic acid increases from room temperature to 120 °C, while at higher temperature it starts to condense to polyimide. Optical analysis shows that TPP is incorporated in the film matrix and its chemical state is determined by the interaction with the monomers, polyamic acid and polyimide. After curing the TPP molecules are finely dispersed in the polyimide matrix and their absorption and fluorescence properties are wholly preserved

    Probing the chemical environment of 3-hydroxyflavone doped ormosils by a spectroscopic study of excited state intramolecular proton transfer

    Get PDF
    Abstract The spectroscopic properties of 3-hydroxyflavone (3-HF) molecules entrapped in films and in monoliths of sol–gel derived organically modified silicates (Ormosils) xerogels are studied by excitation and fluorescence spectroscopy as a function of the sol–gel precursors used for the synthesis. Different molar ratios of tetraethoxysilane (TEOS), methyltriethoxysilane (MTES) and phenyltriethoxysilane (PTES) as precursors are used for the sol preparation. Emission and excitation spectra in the ultraviolet–visible range and photo-degradation curves as a function of time are collected with a spectrofluorimeter. The 3-hydroxyflavone optical properties change in the different networks, owing to the effects of the chemical environment on the excited state intramolecular proton transfer and to the solubility of the dye molecules in the different sol–gel systems. It turns out that the spectroscopic features can be used to probe the chemical state of the dye molecules microenvironment

    Itinerant electron metamagnetism in LaCo9_9Si4_4

    Full text link
    The strongly exchange enhanced Pauli paramagnet LaCo9_9Si4_4 is found to exhibit an itinerant metamagnetic phase transition with indications for metamagnetic quantum criticality. Our investigation comprises magnetic, specific heat, and NMR measurements as well as ab-initio electronic structure calculations. The critical field is about 3.5 T for HcH||c and 6 T for HcH\bot c, which is the lowest value ever found for rare earth intermetallic compounds. In the ferromagnetic state there appears a moment of about 0.2 μB\mu_B/Co at the 16k16k Co-sites, but sigificantly smaller moments at the 4d and 16l16l Co-sites.Comment: 11 pages, 5 figures, PRB Rapid Communication, in prin

    The UA9 experimental layout

    Full text link
    The UA9 experimental equipment was installed in the CERN-SPS in March '09 with the aim of investigating crystal assisted collimation in coasting mode. Its basic layout comprises silicon bent crystals acting as primary collimators mounted inside two vacuum vessels. A movable 60 cm long block of tungsten located downstream at about 90 degrees phase advance intercepts the deflected beam. Scintillators, Gas Electron Multiplier chambers and other beam loss monitors measure nuclear loss rates induced by the interaction of the beam halo in the crystal. Roman pots are installed in the path of the deflected particles and are equipped with a Medipix detector to reconstruct the transverse distribution of the impinging beam. Finally UA9 takes advantage of an LHC-collimator prototype installed close to the Roman pot to help in setting the beam conditions and to analyze the efficiency to deflect the beam. This paper describes in details the hardware installed to study the crystal collimation during 2010.Comment: 15pages, 11 figure, submitted to JINS

    Development and preliminary evaluation of the VPS ReplaySuite: a virtual double-headed microscope for pathology

    Get PDF
    BACKGROUND: Advances in computing and telecommunications have resulted in the availability of a range of online tools for use in pathology training and quality assurance. The majority focus on either enabling pathologists to examine and diagnose cases, or providing image archives that serve as reference material. Limited emphasis has been placed on analysing the diagnostic process used by pathologists to reach a diagnosis and using this as a resource for improving diagnostic performance. METHODS: The ReplaySuite is an online pathology software tool that presents archived virtual slide examinations to pathologists in an accessible video-like format, similar to observing examinations with a double-headed microscope. Delivered through a customised web browser, it utilises PHP (Hypertext PreProcessor) to interact with a remote database and retrieve data describing virtual slide examinations, performed using the Virtual Pathology Slide (VPS). To demonstrate the technology and conduct a preliminary evaluation of pathologists opinions on its potential application in pathology training and quality assurance, 70 pathologists were invited to use the application to review their own and other pathologists examinations of 10 needle-core breast biopsies and complete an electronic survey. 9 pathologists participated, and all subsequently completed an exit survey. RESULTS: Of those who replayed an examination by another pathologist, 83.3% (5/6) agreed that replays provided an insight into the examining pathologists diagnosis and 33.3% (2/6) reconsidered their own diagnosis for at least one case. Of those who reconsidered their original diagnosis, all re-classified either concordant with group consensus or original glass slide diagnosis. 77.7% (7/9) of all participants, and all 3 participants who replayed more than 10 examinations stated the ReplaySuite to be of some or great benefit in pathology training and quality assurance. CONCLUSION: Participants conclude the ReplaySuite to be of some or of great potential benefit to pathology training and quality assurance and consider the ReplaySuite to be beneficial in evaluating the diagnostic trace of an examination. The ReplaySuite removes temporal and spatial issues that surround the use of double-headed microscopes by allowing examinations to be reviewed at different times and in different locations to the original examination. While the evaluation set was limited and potentially subject to bias, the response of participants was favourable. Further work is planned to determine whether use of the ReplaySuite can result in improved diagnostic ability

    Experimental study of the radiation emitted by 180-GeV/c electrons and positrons volume-reflected in a bent crystal

    Get PDF
    The radiation emitted by 180-GeV/c volume-reflected electrons and positrons impinging on a bent crystal has been measured by the H8RD22 Collaboration on the H8 beamline at the CERN SPS. A dedicated spectrometer has been developed to measure high-energy photon spectra (up to similar to 100 GeV) under volume reflection: photon and charged particle beams have been separated by a bending magnet and leptons were detected and tagged by microstrip silicon detectors and a Pb-scintillator sampling calorimeter. A comparison between the experimental and analytical data for the amorphous and volume-reflection cases is presented and the differences are discussed

    Experimental study of the radiation emitted by 180-GeV/c electrons and positrons volume-reflected in a bent crystal

    Get PDF
    The radiation emitted by 180-GeV/c volume-reflected electrons and positrons impinging on a bent crystal has been measured by the H8RD22 Collaboration on the H8 beamline at the CERN SPS. A dedicated spectrometer has been developed to measure high-energy photon spectra (up to similar to 100 GeV) under volume reflection: photon and charged particle beams have been separated by a bending magnet and leptons were detected and tagged by microstrip silicon detectors and a Pb-scintillator sampling calorimeter. A comparison between the experimental and analytical data for the amorphous and volume-reflection cases is presented and the differences are discussed
    corecore