2,241 research outputs found

    Online Library Package to Boost the Functionality and Usability of the Existing Libraries

    Get PDF
    The current computational era has given rise to the idea of the digital library. The essential purpose of digital libraries is to enable readers to more easily explore books for reading. The library is a fast-growing process. The prehistoric system of maintaining it is no longer efficient. Library staff handles tedious tasks which involve sorting, lending, returning, classification of books etc. In addition, library users encounter problems for searching, borrowing, renewing the book, queuing, and so on. To overcome these barriers, this paper proposes a smart E-library Application based on Android technology. It mainly focuses on the central operations in a Library like analyzing total books, calculating available books, updating information, searching books and a facility to request and return books. This Software package is an Android Application developed for android O.S based phones, intended to help users to maintain and organize Library Services. This software package is user-friendly. It will allow quick transactions and will make easy to handle the issue and return of books from the Library without much involvement of manual bookkeeping. This software has been developed to maintain all the daily work of the library. It has many features which are generally not available in normal library systems like facility of reader login and a facility of admin login. The admin can monitor the whole system

    Pregnancy outcome in a rare case of complex cyanotic congenital heart disease

    Get PDF
    A 28 year old primigravida with the very rare congenital heart condition of single ventricle with single atrium presented with 34 weeks gestation, and underwent caesarean section with minimal morbidity. As the condition is not known for survival into adulthood, the carrying of a pregnancy successfully to near term makes this an even rarer case

    Continuous Casting of Multi-Alloy Metal Products and Related Methods

    Get PDF
    Described are multi-alloy metal products formed by a continuous casting system, as well as methods of continuously casting multi-alloy metal products. The disclosed multi-alloy metal product includes a plurality of layers of metallurgically bonded together metal alloys. The layers can be distributed along the thickness of the metal product or along the width of the metal product. The disclosed continuous casting system includes a plurality of injectors configured to simultaneously inject a plurality of metal alloys into a casting cavity to form the multi-alloy metal product

    Stabilnost amlodipin besilata i atenolola u jednoslojnim i dvoslojnim tabletama

    Get PDF
    Multi-drug tablets of amlodipine besylate and atenolol were prepared as either mono-layer (mixed matrix) or bi-layer tablets containing each drug in a separate layer by using similar excipients and processing. Each tablet batch was packed in strip and blister packs and kept under accelerated temperature and humidity conditions. The stability of two tablet and packaging types was compared by HPLC analysis after 0, 1, 3 and 4.5 months and expressed as the content of intact amlodipine and atenolol. The content of atenolol did not decline regardless of tablet and packaging type. Amlodipine content in bi-layer tablets decreased to about 95 and 88% when packed in strips and blisters, respectively. When prepared as mono-layer tablets, the content decreased to 72 and 32%, respectively. The study revealed that the bi-layer tablet formulation was more stable than the mono-layer type. Further, the stability was increased when the tablets were packed in aluminium strips as compared to PVC blisters.Tablete s amlodipinom i atenololom pripremljene su ili u obliku jednoslojne tablete (miješani matriks) ili kao dvoslojne tablete (lijekovi u zasebnim slojevima) koristeći slične pomoćne tvari i uvjete tabletiranja. Tablete su pakirane u dvije vrste pakiranja, aluminijske folije (strip) ili PVC (blister) i čuvane u uvjetima ubrzanog starenja. Stabilnost je određivana pomoću HPLC metode nakon 0, 1, 2, 3 i 4,5 mjeseci i izražena kao sadržaj intaktnog lijeka. Sadržaj atenolola nije se značajno promijenio bez obzira na tip tablete ili pakiranje. Sadržaj amlodipina u dvoslojnim tabletama smanjio se na 95 % (tablete u strip pakiranju) i 88 % (tablete u blister pakiranju). Istodobno, u jednoslojnom tipu kombiniranih tableta sadržaj se smanjio na 72 % (strip pakiranje) i 32 % (blister pakiranje). Rezultati pokazuju da su dvoslojne tablete s amlodipinom i atenololom stabilnije od jednoslojnih. Štoviše, pakiranje tableta u aluminijsku foliju u obliku strip pakiranja povećava njihovu stabilnost u usporedbi s PVC pakirnim materijalom (blister)

    Intravesical rAd-IFNα/Syn3 for Patients With High-Grade, Bacillus Calmette-Guerin-Refractory or Relapsed Non-Muscle-Invasive Bladder Cancer: A Phase II Randomized Study.

    Get PDF
    Purpose Many patients with high-risk non-muscle-invasive bladder cancer (NMIBC) are either refractory to bacillus Calmette-Guerin (BCG) treatment or may experience disease relapse. We assessed the efficacy and safety of recombinant adenovirus interferon alfa with Syn3 (rAd-IFNα/Syn3), a replication-deficient recombinant adenovirus gene transfer vector, for patients with high-grade (HG) BCG-refractory or relapsed NMIBC. Methods In this open-label, multicenter (n = 13), parallel-arm, phase II study ( ClinicalTrials.gov identifier: NCT01687244), 43 patients with HG BCG-refractory or relapsed NMIBC received intravesical rAd-IFNα/Syn3 (randomly assigned 1:1 to 1 × 10(11) viral particles (vp)/mL or 3 × 10(11) vp/mL). Patients who responded at months 3, 6, and 9 were retreated at months 4, 7, and 10. The primary end point was 12-month HG recurrence-free survival (RFS). All patients who received at least one dose were included in efficacy and safety analyses. Results Forty patients received rAd-IFNα/Syn3 (1 × 10(11) vp/mL, n = 21; 3 × 10(11) vp/mL, n = 19) between November 5, 2012, and April 8, 2015. Fourteen patients (35.0%; 90% CI, 22.6% to 49.2%) remained free of HG recurrence 12 months after initial treatment. Comparable 12-month HG RFS was noted for both doses. Of these 14 patients, two experienced recurrence at 21 and 28 months, respectively, after treatment initiation, and one died as a result of an upper tract tumor at 17 months without a recurrence. rAd-IFNα/Syn3 was well tolerated; no grade four or five adverse events (AEs) occurred, and no patient discontinued treatment because of an adverse event. The most frequently reported drug-related AEs were micturition urgency (n = 16; 40%), dysuria (n = 16; 40%), fatigue (n = 13; 32.5%), pollakiuria (n = 11; 28%), and hematuria and nocturia (n = 10 each; 25%). Conclusion rAd-IFNα/Syn3 was well tolerated. It demonstrated promising efficacy for patients with HG NMIBC after BCG therapy who were unable or unwilling to undergo radical cystectomy

    Exclusion Limits on the WIMP-Nucleon Cross-Section from the First Run of the Cryogenic Dark Matter Search in the Soudan Underground Lab

    Full text link
    The Cryogenic Dark Matter Search (CDMS-II) employs low-temperature Ge and Si detectors to seek Weakly Interacting Massive Particles (WIMPs) via their elastic scattering interactions with nuclei. Simultaneous measurements of both ionization and phonon energy provide discrimination against interactions of background particles. For recoil energies above 10 keV, events due to background photons are rejected with >99.99% efficiency. Electromagnetic events very near the detector surface can mimic nuclear recoils because of reduced charge collection, but these surface events are rejected with >96% efficiency by using additional information from the phonon pulse shape. Efficient use of active and passive shielding, combined with the the 2090 m.w.e. overburden at the experimental site in the Soudan mine, makes the background from neutrons negligible for this first exposure. All cuts are determined in a blind manner from in situ calibrations with external radioactive sources without any prior knowledge of the event distribution in the signal region. Resulting efficiencies are known to ~10%. A single event with a recoil of 64 keV passes all of the cuts and is consistent with the expected misidentification rate of surface-electron recoils. Under the assumptions for a standard dark matter halo, these data exclude previously unexplored parameter space for both spin-independent and spin-dependent WIMP-nucleon elastic scattering. The resulting limit on the spin-independent WIMP-nucleon elastic-scattering cross-section has a minimum of 4x10^-43 cm^2 at a WIMP mass of 60 GeV/c^2. The minimum of the limit for the spin-dependent WIMP-neutron elastic-scattering cross-section is 2x10^-37 cm^2 at a WIMP mass of 50 GeV/c^2.Comment: 37 pages, 42 figure

    Low-threshold analysis of CDMS shallow-site data

    Get PDF
    Data taken during the final shallow-site run of the first tower of the Cryogenic Dark Matter Search (CDMS II) detectors have been reanalyzed with improved sensitivity to small energy depositions. Four ~224 g germanium and two ~105 g silicon detectors were operated at the Stanford Underground Facility (SUF) between December 2001 and June 2002, yielding 118 live days of raw exposure. Three of the germanium and both silicon detectors were analyzed with a new low-threshold technique, making it possible to lower the germanium and silicon analysis thresholds down to the actual trigger thresholds of ~1 keV and ~2 keV, respectively. Limits on the spin-independent cross section for weakly interacting massive particles (WIMPs) to elastically scatter from nuclei based on these data exclude interesting parameter space for WIMPs with masses below 9 GeV/c^2. Under standard halo assumptions, these data partially exclude parameter space favored by interpretations of the DAMA/LIBRA and CoGeNT experiments' data as WIMP signals, and exclude new parameter space for WIMP masses between 3 GeV/c^2 and 4 GeV/c^2.Comment: 18 pages, 12 figures, 5 table

    New Results from the Cryogenic Dark Matter Search Experiment

    Full text link
    Using improved Ge and Si detectors, better neutron shielding, and increased counting time, the Cryogenic Dark Matter Search (CDMS) experiment has obtained stricter limits on the cross section of weakly interacting massive particles (WIMPs) elastically scattering from nuclei. Increased discrimination against electromagnetic backgrounds and reduction of neutron flux confirm WIMP-candidate events previously detected by CDMS were consistent with neutrons and give limits on spin-independent WIMP interactions which are >2X lower than previous CDMS results for high WIMP mass, and which exclude new parameter space for WIMPs with mass between 8-20 GeV/c^2.Comment: 4 pages, 4 figure
    corecore