108 research outputs found
Long-term results of iliac aneurysm repair with iliac branched endograft. A 5-year experience on 100 consecutive cases
Background: Iliac branch device (IBD) technique has been introduced as an appealing and effective solution to avoid complications occurring during repair of aorto-iliac aneurysm with extensive iliac involvement. Nevertheless, no large series with long-term follow-up of IBD are available. The aim of this study was to analyse safety and long-term efficacy of IBD in a consecutive series of patients.Methods: Between 2006 and 2011, 100 consecutive patients were enrolled in a prospective database on IBD. Indications included unilateral or bilateral common iliac artery aneurysms combined or not with abdominal aneurysms. Patients were routinely followed up with computed tomography. Data were reported according to the Kaplan-Meier method.Results: There were 96 males, mean age 74.1 years. Preoperative median common iliac aneurysm diameter was 40 mm (interquartile range (IQR): 35-44 mm). Sixty-seven patients had abdominal aortic aneurysm >35 mm (IQR: 40-57 mm) associated with iliac aneurysm. Eleven patients presented hypogastric aneurysm. Twelve patients underwent isolated iliac repair with IBD and 88 patients received associated endovascular aortic repair. Periprocedural technical success rate was 95%, with no mortality. Two patients experienced external iliac occlusion in the first month. At a median follow-up of 21 months (range 1-60) aneurysm growth >3 mm was detected in four iliac (4%) arteries. Iliac endoleak (one type III and two distal type I) developed in three patients and buttock claudication in four patients. Estimated patency rate of internal iliac branch was 91.4% at 1 and 5 years. Freedom from any reintervention rate was 90% at 1 year and 81.4% at 5 years. No late ruptures occurred.Conclusions: Long-term results show that IBD use can ensure persistent iliac aneurysm exclusion at 5 years, with low risk of reintervention. This technique can be considered as a first endovascular option in patients with extensive iliac aneurysm disease and favourable anatomy. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved
Does the Presence of an Iliac Aneurysm Affect Outcome of Endoluminal AAA Repair? An Analysis of 336 Cases
AbstractObjective: to determine whether the presence of an iliac aneurysm compromises outcome of endovascular exclusion of AAA and to ascertain the fate of the iliac aneurysmal sac.Patients and methods: between April 1997 and March 2001, data on 336 consecutive patients undergoing endovascular repair for AAA were entered in a prospective database. Suitability for endovascular repair was assessed by preoperative contrast-enhanced computed tomography. A maximum common iliac artery (CIA) diameter â„20mm was defined as iliac aneurysm. Patients with and without iliac aneurysms were compared to early (immediate conversion or perioperative death) and late failure (increase in aneurysm diameter or persisting graft-related endoleak, or late AAA rupture or conversion).Results: fifty-nine patients (18%) had iliac aneurysms, 19 were bilateral, for a total of 78 aneurysmal iliac arteries (median diameter 23mm; range 20â50mm). A distal seal was achieved by landing in 33 external iliac arteries, in 20 ectatic CIAs, and in 25 normal CIAs. Operating time differed significantly between patients with and without CIA aneurysms (153±71 vs 123±55min,p =0.0001), whereas no statistically significant differences were found with respect to early and late failure (2% vs 3%, p=0.5 and 14% vs 8%, p=0.11, respectively). There were no cases of buttock or colon necrosis. At a median follow-up of 14 months (range 0â46; i.q.r. 7â27 months) common iliac diameter decreased â„2mm in 49 cases, remained stable in 25, and increased â„2mm in 3.Conclusion: the presence of iliac aneurysm rendered endoluminal AAA repair more complex but did not affect feasibility and long-term outcome of the procedure. In our experience internal iliac exclusion was never associated with significant morbidity. These data may be useful when considering endovascular repair in high-risk patients with challenging anatomy
Second-generation Thienopyridine use is not Associated with Better Early Perioperative Outcome During Carotid Stenting
AbstractObjectiveManagement of anti-platelet therapy during carotid artery stenting (CAS) is mainly based on indirect evidence from coronary stenting experience. There is common agreement on the use of thienopyridine (mainly second-generation) during CAS, but some patients are unsuitable for clopidogrel treatment and data on the benefit of its use in large CAS populations are lacking. The aim of this study was to investigate whether clopidogrel was associated with reduced perioperative morbidity in patients undergoing CAS.MethodsConsecutive patients undergoing CAS for primary carotid stenosis from 2004 to 2009 were reviewed. The independent association of clopidogrel and perioperative morbidity was assessed using multivariable analysis.ResultsA total of 1083 patients were treated (29% females, mean age 71.6 years); 825 (76%) patients were given clopidogrel starting before treatment. Clopidogrel use was associated with a non-significant reduction of perioperative stroke/death (4.3% vs. 2.4%; p = 0.13) and disabling stroke (1.2% vs. 1.0%; p = 1) rates. The non-significant stroke/death difference was similar in symptomatic (5.8% vs. 4.0%, p = 0.37) and asymptomatic (3.7% vs. 1.9%; p = 0.17) patients. After adjusting for demographics, co-morbidities and other therapies with multivariable analysis, clopidogrel use failed to show any significant independent association in decreasing operative risks. The only independent protective factor was use of statins (p = 0.010). The additional use of dual anti-platelet therapy did not add any advantage to the use of clopidogrel alone.ConclusionsThe suggested benefit of clopidogrel in decreasing the incidence of complications in patients undergoing CAS may be overestimated due to the overlapping effect of other more relevant factors (e.g., pleiotropy and plaque stabilisation from statins). More data and level I evidence are needed to understand which is the best medical management of CAS that will help improve outcomes of the procedure
Quality of Life in Patients with Small Abdominal Aortic Aneurysm: The Effect of Early Endovascular Repair Versus Surveillance in the CAESAR Trial
AbstractObjectiveTo evaluate and compare changes over time in health-related quality of life reported by patients with small (4.1â5.4 cm) abdominal aortic aneurysms (AAAs) undergoing endovascular aortic aneurysm repair (EVAR) or surveillance.MethodsParticipants were randomly assigned to receive either early EVAR or surveillance within a multicentre, randomised clinical trial on small AAA (Comparison of surveillance vs. Aortic Endografting for Small Aneurysm Repair, CAESAR). Patient-reported health-related quality of life was assessed before randomisation, at 6 months and yearly thereafter using the Short Form 36 (SF-36) Health Survey.ResultsBetween 2004 and 2008, 360 patients (345 males, mean age 68.9 years) were randomised, 182 to early EVAR and 178 to surveillance. There was one perioperative death. Mean follow-up was 31.8 months. No significant difference in survival was found. At baseline, comparable quality of life scores were recorded in both treatment groups: Total SF-36: 73.0 versus 75.5 (p = 0.18), Physical domain: 71.4 versus 73.3 (p = 0.33); Mental health domain: 70.9 versus 72.7 (p = 0.33), in the EVAR arm versus the surveillance arm, respectively. Six months after randomisation, Total SF-36 and Physical and Mental domain scores were all significantly higher with respect to baseline in the EVAR group, while patients of the surveillance group scored lower. The differences between EVAR and surveillance arms in score changes at 6 months were significant and in favour of EVAR: Total score: difference 5.4; p = 0.0017; Physical: difference 3.8; p = 0.02; and Mental: difference 6.0; p = 0.0005. Differences between EVAR and surveillance diminished over time. At the last assessment, patients in both groups had decreased scores with a significant drop with respect to the baseline (â3.9 in EVAR, â6.3 in surveillance). There were no significant differences between the EVAR and surveillance arms: Total score: p = 0.25; Physical: p = 0.47; and Mental: p = 0.38.ConclusionsPatients with small AAA under surveillance compared with early EVAR had significant impaired functional health at 6 months after assignment. After a mean of 31.8 months, SF-36 health-related quality of life in patients allocated to early EVAR and surveillance was similar
Studio della formazione di retinature in una lega dâalluminio 6061 anodizzata
Nel presente lavoro sono esaminate le possibili cause del fenomeno delle retinature superficiali che si possono presentare su particolari in lega di alluminio sottoposti ad anodizzazione e fissaggio. In particolare sono stati presi in esame diversi parametri influenzanti il fenomeno, quali la tipologia del fissaggio, lo spessore dello strato dâossido, le condizioni di temperatura ed umiditĂ in cui i campioni sono conservati. Sono state inizialmente indagate le proprietĂ strutturali e meccaniche dello strato dâossido superficiale, rispettivamente mediante misure di diffrazione di raggi X a fascio parallelo e prove di microdurezza. Successivamente sono state condotte prove mediante riscaldamenti controllati su campioni conservati a temperature pari od inferiori a quella ambiente e su provini conservati in assenza di umiditĂ (ovvero sotto vuoto)
Role of Duplex Scan in Endoleak Detection After Endoluminal Abdominal Aortic Aneurysm Repair
AbstractObjective: to validate the role of duplex scan in endoleak detection in postoperative surveillance of endoluminal abdominal aneurysm repair (EAAR). Patients and methods between April 1997 and March 1999, 103 patients were eligible for duplex and computed tomography (CT) scan after EAAR. Mean follow-up was 8 months (range 1â24 months). The study protocol comprised concurrent examination with colour-duplex and CT scan at 1, 6, and 12 months after EAAR, for a total of 198 concurrent examinations. All duplex scan examinations were performed by two vascular surgeons with the same machine (ATL HDI 3000). Interobserver agreement in endoleak detection (Îș=1) and in type of endoleak (Îș=0.7) was evaluated in 50 random duplex examinations. Endoleak detection was examined comparatively in duplex and CT scan, the latter being the gold standard. Sensitivity and specificity tests together with negative- and positive-predictive values (NPV and PPV) were calculated. Results duplex scan was not feasible in one patient. On CT scan the endoleak rate was 4% at one month, 3% at 6 months, and 4% at one year. Overall, CT scan detected 12 endoleaks. With respect to endoleak detection, duplex scan revealed a great ability in ruling out false-negative results (sensitivity 91.7%, NPV 99.4%), but overestimated the presence of endoleak (specificity 98.4%, PPV 78.6%). Regarding type of endoleak, the ability of duplex scan to identify the source of endoleak was low (sensitivity 66.7%). Conclusions duplex scan, if validated, appears to be a reliable means for excluding the presence of endoleak after EAAR
The new educational project Televascular Games during the Coronavirus Disease 2019 pandemic
Objective: To report methodology and first-year results of a new educational project called Televascular Games,â which took place during coronavirus disease 2019 pandemic. Methods: Complex aneurysmal aortic disease was discussed during a 2-hour competition webinar, according to three modalities. (1) Planning case competition (PCC): Two to four preoperative computed tomography angiography (CTA) scans of an already performed selected case were submitted for the competition. CTA scans were uploaded anonymously, without any reference to the center or the surgeon who performed the case. The competitor had to prepare a presentation of how he or she would have diagnosed, sized, planned, treated, and followed up the case, of the medical therapy and of the bail-out maneuvers. (2) Challenging case competition (CCC): The competitor elaborates a presentation of an already treated case concerning an aortic topic and discusses sizing, planning, treatment, possible bail-out maneuvers and obtained results. For the CCC and PCC, the competitors with the best score were preselected to present and discuss their plan during the webinars. (3) Quiz competition: Two to six CTA scans of already performed selected aortic cases were submitted for the competition. A quiz with multiple choice questions was answered by the competitors. The top four competitors were selected for the webinars and then they discussed the cases during the webinar. Finally, at the end of the case discussion, the effective case resolution and follow-up were shown. A final winner was voted via televoting, based on six preestablished criteria. The project was endorsed by different national and international societies. Results: Between October 2020 and December 2021, there were 12 Italian and 1 international webinars with 1695 participants overall (mean, 130; range, 86-177). Competitors were 54 years of age (mean, 27 years; range, 22-38 years). Two editions were CCCs, two quiz competitions, and nine PCCs. The reliability of the interobserver sizing of competitors was Îș = 0.43 and Îș = 0.62 for the proximal and distal sealing measurements respectively and very good (Îș = 0.88-0.95) in the evaluation of orientation of the vessels, presence of angulations, calcifications, and thrombus. The sizing discrepancy resulted in a significant variability of the planning (Îș = 0.45). The project ranked 9.6 on a 10-point rating scale by all the participants and competitors. Conclusions: The formula of gaming and collegial discussion of aortic cases herein reported has proved valid and attractive during coronavirus disease 2019 pandemic period. The variability of the results on sizing and planning suggested to confer with a second opinion, especially for less experienced surgeons
Outcomes of âAnterior Versus Posterior Divisional Branches of the Hypogastric Artery as Distal Landing Zone for Iliac Branch Devicesâ: The International Multicentric R3OYAL Registry
Objective: The aim of this multicentric registry was to assess the outcomes of âanteRior versus posteRior divisional bRanches Of the hYpogastric artery as distAl landing zone for iLiac branch devices (R3OYAL).â Methods: The main exposure of interest for the purpose of this study was the internal iliac artery (IIA) divisional branch (anterior vs posterior) that was used as distal landing zone. Early endpoints included technical success and adverse events. Late endpoints included survival, primary/secondary IIA patency, and IIA branch instability. Results: A total of 171 patients were included in the study, of which 50 received bilateral implantation of iliac branch devices (IBDs). This resulted in a total of 221 incorporated IIAs included in the final analysis, of which 40 were anterior divisional branches and 181 were posterior divisional branches. Technical success was high in both groups (anterior division: 98% vs posterior division: 100%, P =.18). Occurrence of any adverse event was noted in 14% of patients in both groups (P = 1.0). The overall rate of freedom from the composite IBD branch instability did not show significant differences between patients receiving distal landing in the anterior or posterior division of the IIA at 3 years (79% vs 87%, log-rank test =.215). The 3-year estimates of IBD patency were significantly lower in patients who received distal landing in the anterior divisional branch than those who received distal landing in the posterior divisional branch (primary patency: 81% vs 96%, log-rank test =.009; secondary patency: 81% vs 97%, log-rank test <.001). Conclusions: The use of the anterior or posterior divisional branches of the IIA as distal landing zone for IBD implantation shows comparable profiles in terms of immediate technical success, perioperative safety, and side-branch instability up to 3 years. However, IBD patency at 3 years was higher when the distal landing zone was achieved within the posterior divisional branch of the IIA. Clinical Impact: The results from this large multicentric registry confirm that use of the anterior or posterior divisional branches of the internal iliac artery (IIA) as distal landing zone for implantation of iliac branch devices (IBD) shows comparable profiles of safety and feasibility, thereby allowing to extend the indications for endovascular repair of aorto-iliac aneurysms to cases with unsuitable anatomy within the IIA main trunk. Although mid-term rates of device durability and branch instability seem to be similar, the rates of primary and secondary IBD patency at three years was favored when the distal landing zone was achieved in the posterior divisional branch of the IIA
- âŠ