    Poly(adenosine diphosphate-ribose) polymerase 1 expression in malignant melanomas from photoexposed areas of the head and neck region.

    Get PDF
    Summary The family of the poly(adenosine diphosphate-ribose) polymerase (PARP) proteins is directly involved in genomic stability, DNA repair, and apoptosis by DNA damage. In this study, we evaluated the role of PARP-1 in melanoma and its prognostic importance. We studied by immunohistochemistry and Western blot analysis PARP-1 expression in a selected series of 80 primary melanoma of the head and neck region. The results were correlated with tumor thickness and patient’s outcome. A follow-up of at least 3 years was available. Fifteen cases of benign melanocytic nevi were used as controls. Normal melanocytes showed only scattered, focal nuclear positivity and were considered as negative for PARP-1 expression by immunohistochemistry (score, 0). Thirty cases of melanoma (37.5%) showed nuclear expression of PARP-1 in both radial and vertical growth phases. Western blot analysis showed the presence of a high signal for full-length PARP-1 only in the cases with high immunohistochemical (nuclear) expression of protein (score, ++/+++) in both radial and vertical growth phase. A significant correlation was present between PARP-1 expression in vertical growth phase and the thickness of tumor lesion ( P = .014); all but one tumor measuring less than 0.75 mm showed no or low PARP-1 expression. No correlation was found between PARP-1 expression in radial growth phase and tumor thickness ( P = .38, data not shown). These data suggest that PARP-1 overexpression is a potential novel molecular marker of aggressive cutaneous malignant melanoma and a direct correlation between PARP-1–mediated inhibition of the apoptosis and biologic behavior of cutaneous malignant melanoma

    A new resorbable device for ligation of blood vessels - A pilot study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>During surgery, controlled haemostasis to prevent blood loss is vital for a successful outcome. It can be difficult to ligate vessels located deep in the abdomen. A device that is easy to use and enables secure ligatures could be beneficial. Cable ties made of nylon have been used for ligation but the non-resorbable material caused tissue reactions. The objective of this study was to use a resorbable material to construct a device with a self-locking mechanism and to test its mechanical strength and ligation efficiency.</p> <p>Methods</p> <p>The device was manufactured by injection moulding of polydioxanone, a resorbable polymer used for suture materials. Polydioxanone with inherent viscosities of 1.9 dL/g and 1.3 dL/g were tested. The device consisted of a perforated flexible band which could be pulled through a case with a locking mechanism. After a first version of the device had been tested, some improvements were made. The locking case was downsized, corners were rounded off, the band was made thicker and the mould was redesigned to produce longer devices. Tensile tests were performed with the second version.</p> <p>The first version of the device was used to ligate the ovarian pedicle in a euthanized dog and to test echogenicity of the device with ultrasound. Compression of vessels of the ovarian pedicle was examined by histology. Both versions of the device were tested for haemostasis of and tissue grip on renal arteries in six anaesthetised pigs.</p> <p>Results</p> <p>The tensile strength of the flexible band of the devices with inherent viscosity of 1.9 dL/g was 50.1 ± 5.5 N (range 35.2-62.9 N, <it>n </it>= 11) and the devices with inherent viscosity of 1.3 dL/g had a tensile strength of 39.8 ± 8.1 N (range 18.6-54.2 N, <it>n </it>= 11). Injection moulding of the polymer with lower inherent viscosity resulted in a longer flow distance.</p> <p>Both versions of the device had an effective tissue grip and complete haemostasis of renal arteries was verified. The device attached to the ovarian pedicle could be seen with ultrasound, and vessel compression and occlusion were verified by histology.</p> <p>Conclusions</p> <p>Tests of functionality of the device showed complete haemostasis and good tissue grip. Devices with a band of sufficient length were easily applied and tightened in tissue.</p

    Extensive scrotal calcinosis

    No full text
    Sir, We just read the case report entitled” Extensive scrotal calcinosis” by Demirdover et al. [1] and would like to share with the authors and the Journal's readers our clinical experience on the subject
    corecore